Hirose Electric Co Ltd DF3-4S-2DSA(25): fit and lifecycle

DF3-4S-2DSA(25) Hirose Electric Co Ltd product image

30 V AC listed rating, four contacts on 2 mm pitch, straight through-hole mounting.

Quick Engineering Summary

FieldValue
ManufacturerHirose Electric Co Ltd
CategoryRectangular Connectors - Headers, Receptacles, Female Sockets

DF3-4S-2DSA(25): is new design-in settled?

Not yet. The catalog calls the part Active, while its lifecycle classification remains Unknown; neither field establishes a confirmed production status for this exact variant. Ask Hirose to confirm that status before committing a new board. Existing production has a clearer reason to retain the connector if its mate and solder process are already qualified. The catalog identifies it as EU RoHS compliant.

The electrical distinction matters too. The DF3 document gives a 100 V AC series voltage rating, but its UL/CSA rating is 30 V AC. The catalog also lists 30 V AC. Treat that lower figure as the ceiling for a design requiring the stated approval, not as a test voltage or a preferred operating point.

DF3-4S-2DSA(25): what fits on the board?

This is a four-contact, straight through-hole receptacle, not a cable-end socket. The ordering key assigns S to socket and DSA to straight through-hole; the receptacle table assigns (25) to tin plating and tube packaging. Its 2 mm pitch across four contacts gives a first-to-last contact span of 2 mm × (4 − 1) = 6 mm. That span helps check connector placement, but it is not a complete drill pattern. The same table calls for Ø0.8 mm board through-holes.

Hirose describes mating arrangements using a pin header for board-to-board connections and an in-line plug for board-to-cable connections. Choose the mate by orientation and contact finish; a shared pitch alone does not establish a mating pair. The tube format is the ordering constraint for this suffix, so keep the exact suffix on the production BOM.

DF3-4S-2DSA(25): what remains to qualify?

The contact-resistance test gives 30 mΩ maximum at 100 mA. Ohm's law puts the drop at no more than 0.03 Ω × 0.1 A = 0.003 V under that test condition. It does not establish the contact drop at the series' 3 A current rating. That rating depends on the stated wire size for crimp connections, while the operating temperature range of −30 °C to +85 °C includes current-induced temperature rise.

Get Hirose's current engineering drawing and exact-part specification before releasing the footprint or mating arrangement. The series text supplies a hole diameter and contact span, but not enough exact-part dimensional detail here to sign off the PCB layout.

View the Win-Source product page for DF3-4S-2DSA(25).

Key Takeaways for Engineers & Buyers

  • Compare the certified voltage rating with the circuit requirement before approving the BOM.
  • Check the mating contact finish against the tin-plated receptacle before connector qualification.
  • Obtain the exact receptacle drawing before releasing the PCB drill pattern.

How the figures on this page were worked out

ResultFormulaDatasheet inputsValue
First-to-last contact spanspan = pitch × (contacts − 1)pitch = 2 mm (DF3 ordering information, contact pitch, page 3); contacts = 4 contacts (DF3 receptacle table, four-contact straight through-hole entry, page 5)6 mm
Maximum drop at the contact-resistance test conditionV = R × IR = 0.03 Ω (Product specifications, contact resistance maximum 30 mΩ, page 2); I = 0.1 A (Product specifications, contact-resistance test at 100 mA, page 2)0.003 V

Sources