2.00 mm pitch, 5 positions, −55°C to +105°C operating range; contacts are separate.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Hirose Electric Co Ltd |
| Category | Rectangular Connectors |
| Package | 100 |
Is DF3-5S-2C ready for a new harness design?
It is a conditional choice, not a cleared new design-in: the catalog gives its lifecycle as Unknown. Ask Hirose to confirm status before committing the harness drawing; Unknown does not mean discontinued. The catalog marks it compliant with EU RoHS.
The immediate buying constraint is that this is a receptacle housing with contacts not included. Select the crimp contacts for the intended wire before releasing the assembly bill of materials. The specification sheet covers DF3-*S-2C receptacles, while the catalog identifies this variant as a 5-position housing.
What sets the DF3-5S-2C wiring and temperature limits?
This is a free-hanging, single-row crimp receptacle, not a board-mounted connector. The listed 2.00 mm pitch across 5 positions puts the first and last cavity centers 4 × 2.00 mm = 8.00 mm apart. That span helps check harness geometry; it does not supply the housing dimensions or mating interface.
Current depends on wire gauge: the specification sheet lists 3 A per pin for AWG 24, 2 A per pin for AWG 26, and 1 A per pin for AWG 28. Those are ceilings, not a promise that every position can carry its limit at once. The +105°C operating ceiling includes temperature rise caused by current. At an assumed 85°C ambient, +105°C − 85°C leaves 20°C for that rise; this calculation does not establish an allowable current.
What remains unresolved for DF3-5S-2C?
The voltage table in the available specification text prints both 30 V AC/DC and 250 V AC/DC, but its column labels do not clearly assign those figures to their conditions. Neither figure should be used as an operating limit until the original table is checked.
The sheet refers to a drawing without providing it here. The mating-part identification and housing dimensions therefore remain open, as does a temperature-rise result for the intended loaded harness. Those items, rather than the housing name alone, close the wiring choice.
View the Win-Source product page for DF3-5S-2C.
Key Takeaways for Engineers & Buyers
- Match the selected wire gauge to the per-pin current rating before specifying contacts.
- Check the mating drawing against the first-to-last cavity-center span before fixing the harness layout.
- Measure contact heating at the target ambient before accepting the operating-temperature ceiling.
How the figures on this page were worked out
| Result | Formula | Datasheet inputs | Value |
|---|---|---|---|
| First-to-last cavity-center span | span = (positions - 1) × pitch | positions = 5 positions (Catalog specifications, Number of Positions); pitch = 2 mm (Catalog specifications, Pitch) | 8 mm |
| Temperature-rise headroom at an assumed 85°C ambient | headroom = operating temperature ceiling − assumed ambient | operating temperature ceiling = 105 °C (Specification sheet, operating temperature range; Note 1 includes temperature rise by current); assumed ambient = 85 °C (Specification sheet, rapid-change-of-temperature test step; used here only as a hypothetical ambient) | 20 °C |