Five-position, 2 mm through-hole receptacle; series ratings need application-specific checks.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Hirose Electric Co Ltd |
| Category | Rectangular Connectors |
| Package | 40 |
The DF3 gold receptacle is a conditional new design-in
DF3-5S-2DSA(55) is a plausible board-mounted choice, but its lifecycle is unverified. Ask Hirose to confirm the exact variant's status before committing a new assembly; the Unknown catalog status is not evidence of discontinuation. For an existing line, retain the exact suffix when specifying the part. The catalog marks it EU RoHS compliant.
The ordering table identifies this as a five-contact socket receptacle on 2 mm pitch. DSA selects straight through-hole termination, and (55) selects gold-plated contacts in tube packaging. That suffix matters: a tin-plated ordering variant is not the specified mating finish. The DF3 series sheet directs designers to request the current engineering drawing for part-specific dimensions.
DF3 current and voltage figures do not grant blanket approval
The series current table gives 3 A with AWG 22–24 crimp wiring, falling to 2 A with AWG 26 and 1 A with AWG 28. Those are application-dependent ceilings, not an unconditional board-to-board rating for this receptacle. At the stated 100 mA contact-resistance test current, 0.1 A × the 0.03 Ω maximum gives a calculated 0.003 V contact drop. That calculation describes the test point, not drop at full current.
For a heating budget only, 3 A × 3 A × 0.03 Ω gives 0.27 W per contact if the measured resistance ceiling persists at 3 A. The sheet does not establish that assumption or give a thermal path for this assembly. Its general series voltage rating is 100 V AC, while the catalog lists 30 VAC. The sheet's 30 V AC safety table names other product codes, not this receptacle; neither figure establishes approval for this exact variant.
DF3 mating geometry decides where this receptacle belongs
This straight through-hole receptacle belongs on a PCB, mating with a suitable DF3 header for a board connection or with the series in-line plug for a cable connection. The series sheet describes a 6.6 mm horizontal board-to-board arrangement when the receptacle is paired appropriately. It does not make that height universal across mating orientations. A friction-lock connection is not a substitute for checking retention in the actual enclosure.
The immediate gap is the current engineering drawing: the series table gives dimensions, but not the complete, current footprint and mating geometry for this exact build. Obtain that drawing and compare the selected mate's orientation and board spacing before releasing the PCB. The tube-packaged (55) variant also calls for a receiving and placement process that handles tubes rather than an assumed tape-fed part.
View the Win-Source product page for DF3-5S-2DSA(55).
Key Takeaways for Engineers & Buyers
- Check the 0.8 mm through-hole requirement against the released drill specification.
- Compare the gold contact's 50-cycle durability limit with planned service disconnects.
- Check the safety-file's named product codes before marking this receptacle approved.
How the figures on this page were worked out
| Result | Formula | Datasheet inputs | Value |
|---|---|---|---|
| Contact drop at the resistance test current | V = I × R | I = 0.1 A (DF3 series product specifications, contact resistance measured at 100 mA); R = 0.03 Ω (DF3 series product specifications, 30 mΩ maximum contact resistance at 100 mA) | 0.003 V |
| Conditional per-contact heating budget at the highest listed crimp-wire current | P = I² × R | I = 3 A (DF3 series current-rating table, AWG 22–24 crimp wiring); R = 0.03 Ω (DF3 series product specifications, 30 mΩ maximum contact resistance measured at 100 mA; persistence at 3 A is unverified) | 0.27 W |