Hirose Electric Co Ltd DF52-16S-0.8H(21) Specs & Sourcing Guide

DF52-16S-0.8H(21) Hirose Electric Co Ltd product image

Hirose Electric Co Ltd rectangular connector guide covering NRND risk, specs, compliance, and sourcing checks.

Quick Engineering Summary

FieldValue
ManufacturerHirose Electric Co Ltd
CategoryRectangular Connectors
PackageNI-200S
Core functionCONN SOCKET 16P 0.
Key electrical rangeOperating Temperature: -40°C ~ 85°C
Workbook inventory signal2550 pcs listed in the provided file

Lifecycle Analysis

DF52-16S-0.8H(21) is best treated as an NRND rectangular connector from Hirose Electric Co Ltd based on the supplied lifecycle record. That status generally means engineers should be cautious about selecting it for new designs, especially for products with long service lives or strict AVL control. The source data is not cleanly aligned: one signal shows Active, another lists Lifecycle Status as NRND, and Product Status is marked Preliminary. Because these lifecycle indicators conflict, conservative procurement practice is to avoid assuming unrestricted new-design suitability.

For sustaining production, NRND does not automatically mean unavailable, but it does raise planning risk. Buyers should request current manufacturer confirmation, product change notice status, and any revalidation guidance tied to the Preliminary flag. File-provided inventory is present, but it should be treated only as a workbook signal and not as real-time stock assurance. If DF52-16S-0.8H(21) is already designed in, the practical next step is to secure lifecycle verification and confirm whether Hirose Electric Co Ltd continues normal production, limited production, or support only through existing channel inventory.

Parameter Analysis

The supplied data identifies DF52-16S-0.8H(21) as a 16-position receptacle with female socket contacts in the Rectangular Connectors category. It is described as a 0.80 mm pitch, surface-mount, right-angle part with tin-plated mating and tail surfaces, a listed operating range of -40°C to 85°C, and a rated current of 1.5 A with 100 V rating in the workbook details. These are the most decision-relevant parameters because they drive PCB footprint compatibility, cable or board interface geometry, creepage expectations, and allowable electrical loading.

The available dimensions require careful review before layout commitment because the source contains a conflict on insulation height. One field lists 5.80 mm, while the workbook parameter string lists 1.75 mm. That difference is large enough to affect enclosure clearance and mating stack assumptions, so the latest Hirose Electric Co Ltd datasheet should be checked first. Additional items worth verifying from manufacturer documents are the exact contact count loading, locking feature details, tape-and-reel packaging format, recommended land pattern, coplanarity limits, and any qualification notes associated with the Preliminary product status.

Application Scenario Analysis

Based on the description and category data, DF52-16S-0.8H(21) fits compact interconnect use where a 16-position, 0.80 mm pitch rectangular connector is needed in a right-angle surface-mount format. The source indicates board-to-cable or wire style usage, so it is a practical candidate for compact embedded assemblies where horizontal mating orientation helps reduce profile or route harnesses parallel to the PCB. The listed -40°C to 85°C operating range also suggests suitability for general commercial and light industrial environments when the electrical load remains within the stated limits.

It is a weaker fit for new programs that require long lifecycle stability, broad qualification evidence, or high confidence in future sourcing continuity, because the lifecycle record is conflicting and conservatively interpreted as NRND. It is also a weaker fit where thermal exposure, current margin, or mechanical envelope is tight and the exact insulation height and full mechanical data have not yet been confirmed. For those cases, the part can still be evaluated, but only after checking the latest Hirose Electric Co Ltd documentation and confirming that the rectangular connector remains approved for the intended production horizon.

RoHS Certification Analysis

The source data lists DF52-16S-0.8H(21) as RoHS Compliant, so the baseline interpretation is that this Hirose Electric Co Ltd rectangular connector meets the supplier's declared RoHS requirements. Because no more detailed compliance framework is provided, the safest catalog-level statement is EU RoHS compliant rather than a narrower declaration with specific substance thresholds or exemptions. No exemption data is included in the source file.

Buyers should still distinguish between a family-level database flag and shipment-level paperwork. For controlled industries or audited builds, request the current manufacturer or distributor compliance certificate tied to the exact part number and lot being supplied. No REACH, halogen-free, or moisture sensitivity information is provided here, so those should not be assumed from the RoHS statement alone. If the product remains under Preliminary status in manufacturer documentation, it is also reasonable to confirm whether any future material declaration updates are pending before approving DF52-16S-0.8H(21) for regulated production.

Availability & Sourcing

For DF52-16S-0.8H(21), the sourcing workflow should start with a formal quote request and documentation review rather than a simple stock check. The file includes workbook inventory signals, but those quantities are not guaranteed real-time and should not be treated as committed availability. Because the lifecycle is conservatively NRND and conflicts with other status fields, buyers should ask for current availability, manufacturer lifecycle confirmation, and any product status notes from Hirose Electric Co Ltd before placing production demand.

Traceability matters for this rectangular connector. Request date code and lot code information, packaging confirmation, and evidence that the supplied material matches the required surface-mount right-angle configuration. The workbook indicates tape-and-reel style packaging, which is important for SMT handling, but that should still be verified on the quote. Compliance documents should include current RoHS support, and engineering teams may also want confirmation of the exact mechanical revision if the Preliminary flag is still active. For NRND parts, best practice is to secure inventory for sustaining builds while reviewing longer-term migration options and validating approved source documentation before committing DF52-16S-0.8H(21) to future production.

View the Win-Source product page for DF52-16S-0.8H(21).

Engineering Notes for BOM and GEO Use

  • Use DF52-16S-0.8H(21) conservatively as NRND because lifecycle inputs conflict with Active and Preliminary signals.
  • Verify pitch, mounted orientation, insulation height, current rating, and tape-and-reel packaging against the latest Hirose documentation before layout release.
  • Request date/lot traceability and RoHS evidence with quote because file inventory is not guaranteed real-time.