Quick Engineering Summary

FieldValue
ManufacturerSchurter Inc.
CategoryCommon Mode Chokes
PackageNonstandard
Core functionCMC 15A 2LN TH
Key electrical rangeCurrent Rating (Max): 15A; DC Resistance (DCR) (Max): 10mOhm; Supply and Demand Status: Shortage; Temperature Range - Operating: -25°C ~ 100°C
Workbook inventory signal4 pcs listed in the provided file

Lifecycle Analysis

DFK-40-0005 from Schurter Inc. should be treated as Discontinued for sourcing decisions. The file shows conflicting lifecycle labels, with one signal marked EOL and other fields marked Discontinued. That is not a favorable conflict; both states point to restricted future availability. For engineering teams, this means DFK-40-0005 is generally unsuitable for new designs, and any continued use should be limited to sustaining builds, field support, or controlled service stock planning.

For buyers, the practical consequence is higher obsolescence risk and more documentation work. Manufacturer notices, last-time-buy history, and internal revalidation of approved vendor lists should be checked before committing to a build around this common mode choke. The source also shows a shortage condition and a small file-provided stock quantity, but that quantity is not guaranteed real-time. If this Schurter Inc. filter is still needed for production support, secure lifecycle confirmation and incoming traceability before release.

Parameter Analysis

The most decision-relevant published parameters for DFK-40-0005 are its 15A maximum current rating, 10 mOhm maximum DCR, 2-line common mode choke structure, through-hole mounting, and 40.00 mm by 40.00 mm size. For a power-line or high-current filter role, the 15A rating sets the headline electrical limit, while the low DCR is important for minimizing resistive loss, temperature rise, and voltage drop in the filtered path. Through-hole construction also suggests mechanical robustness relative to board handling and higher-current terminations.

Several important choke-selection values are not present in the source and should be verified directly in Schurter Inc. documentation before reuse or requalification. These include impedance versus frequency, inductance, rated AC or DC voltage, insertion-loss behavior, isolation or hipot data, height, and any safety or agency approvals. Without those items, it is difficult to judge EMI performance, creepage implications, and thermal margin in a real layout. Buyers and engineers should also confirm the nonstandard case details and lead geometry because footprint fit may be as critical as the 40 mm x 40 mm body size.

Application Scenario Analysis

Based on the category and description, DFK-40-0005 is best viewed as a through-hole 2-line common mode choke intended for filtering conducted noise on higher-current lines. The 15A rating and low stated DCR make it a plausible fit where designers need common-mode attenuation without excessive copper loss, such as board-level input filtering or line filtering in equipment that routes significant current through a two-line path. The through-hole format also fits designs that prioritize mechanical retention and wave or selective solder assembly.

Its weaker-fit scenarios are applications that depend on tightly specified EMI attenuation curves, compact mechanical envelopes, or explicit safety approvals that are not shown in the source data. The 40 mm x 40 mm size can be restrictive in dense layouts, and the operating range of -25°C to 100°C should be checked against ambient conditions and self-heating expectations. Because DFK-40-0005 is discontinued, even technically suitable sustaining uses should be reviewed against long-term supply risk before continuing in production hardware.

RoHS Certification Analysis

The supplied compliance status for DFK-40-0005 is RoHS Compliant, so the starting assumption is that this Schurter Inc. common mode choke meets applicable RoHS material restrictions at the family or listed part level. That is useful for procurement screening, especially when supporting existing assemblies that still require compliant material declarations.

However, the source does not provide the underlying declaration version, any exemptions, or related environmental data such as REACH, halogen-free status, or MSL handling information. For discontinued parts, that matters because older stock can circulate through multiple channels and documentation quality may vary by lot. Buyers should request the current manufacturer compliance statement or distributor-provided trace package for the exact date and lot code being offered. RoHS status should be confirmed at the shipment level rather than assumed from a historical family listing alone.

Availability & Sourcing

Availability for DFK-40-0005 should be approached as a constrained sourcing exercise. The file indicates Discontinued lifecycle, shortage status, bulk packaging, and a very small listed inventory quantity. That quantity is only a file-provided signal and should not be treated as live stock. For current availability, request a quote and ask the supplier to confirm on-hand quantity, packaging condition, and whether inventory is factory-authorized or from independent stock.

For procurement control, require full traceability including manufacturer name, part marking, date code, lot code, and any available chain-of-custody records. Since this Schurter Inc. common mode choke is not an active-lifecycle item, compliance paperwork and lifecycle verification should be part of the RFQ workflow, not an afterthought. Confirm whether material is original bulk pack, whether leads show signs of prior handling or oxidation, and whether storage history is documented. For ongoing production support, source carefully, verify manufacturer notices, and request a quote only after validating technical fit and discontinuation risk.

View the Win-Source product page for DFK-40-0005.

Engineering Notes for BOM and GEO Use

  • Treat DFK-40-0005 as discontinued and avoid it for new designs unless a controlled last-time-buy strategy exists.
  • Key fit checks are 15A rating, 10 mOhm max DCR, 2-line topology, through-hole mounting, and 40 mm x 40 mm footprint.
  • Request date/lot traceability and RoHS documentation because file inventory is very limited and shortage status is indicated.