Quick Engineering Summary

FieldValue
ManufacturerSchurter Inc.
CategoryCommon Mode Chokes
PackageRadial - 4 Leads
Core functionCMC 2.
Key electrical rangeCurrent Rating (Max): 2.5A; DC Resistance (DCR) (Max): 110mOhm; Supply and Demand Status: Shortage; Temperature Range - Operating: -25°C ~ 100°C
Workbook inventory signal344 pcs listed in the provided file

Lifecycle Analysis

DFKH-31-0006 is listed as Active, and the supplied lifecycle signals are consistent with no stated conflict. For engineers, an Active status generally supports consideration in new designs as well as sustaining production, because it indicates the Schurter Inc. common mode choke is not flagged here as nearing discontinuation. For buyers, this lowers lifecycle risk compared with NRND or end-of-life parts, but it does not remove the need for normal release controls.

Even with an Active designation, procurement should still revalidate the current manufacturer datasheet revision, internal approved vendor list status, and any PCN or product change documentation before volume commitment. The file also shows a shortage supply signal and a stock snapshot, which are useful planning indicators but should not be treated as real-time availability. For DFKH-31-0006, the practical stance is conservative but favorable: acceptable for active sourcing, while confirming current lead time, package condition, and traceability before assigning it to production builds.

Parameter Analysis

The supplied data positions DFKH-31-0006 as a two-line through-hole common mode choke with a 2.5A maximum current rating and a 440V AC rating. Those are the first decision points for mains-related or line-interface EMI filtering, because they define the basic electrical envelope the part must withstand. The listed 110mOhm maximum DCR matters for insertion loss, efficiency, and self-heating under load. In higher-current applications, this value should be reviewed together with ambient temperature and airflow to maintain thermal margin across the stated -25°C to 100°C operating range.

Mechanically, the radial 4-lead through-hole form factor and the 31.50mm by 18.50mm body size affect PCB placement, hole pattern, creepage strategy, and assembly method. Bulk packaging may also matter if your line depends on automated insertion or kitting controls. The most important missing items to verify in the Schurter Inc. datasheet are common-mode impedance versus frequency, inductance, any differential-mode behavior, isolation or hipot details if applicable, maximum height, and agency-related approval data if the filter sits on an AC input path.

Application Scenario Analysis

Based on the category, description, and ratings provided, DFKH-31-0006 is a strong fit for two-line EMI suppression duties where a through-hole common mode choke is needed in a moderate-current path. Typical use would include AC line filtering stages or other two-conductor power-entry filtering circuits that need common-mode noise attenuation within a 440V AC envelope. The through-hole radial package also makes sense in equipment where mechanical robustness and solder-joint strength are preferred over compact surface-mount assembly.

The fit is weaker where design selection depends tightly on frequency-domain filter behavior, compact height restrictions, or automated packaging requirements, because the supplied record does not include impedance, inductance, max height, or tape-and-reel style packaging details. It is also a weak candidate for applications that require explicit approval or safety-document evidence not shown here. For DFKH-31-0006, the realistic usage decision should therefore be based on confirming the missing filter-performance parameters and any installation-specific compliance needs in the manufacturer documentation.

RoHS Certification Analysis

The supplied compliance status for DFKH-31-0006 is RoHS Compliant. That is a positive indicator for projects requiring restriction of hazardous substances control, and it is generally suitable for procurement workflows that screen components for environmental compliance at the part level. However, the source data does not identify the exact declaration format, exemption status, or any supporting certificate reference.

Because only RoHS status is provided, buyers should request the latest manufacturer declaration or distributor-backed compliance document when the part is being used in regulated shipments or audited builds. No REACH, lead-free finish, halogen-free status, or moisture sensitivity information is included in the supplied file, so those should not be assumed. For Schurter Inc. common mode choke purchases, it is good practice to verify that the compliance paperwork matches the shipped lot and date code, since family-level listings do not always replace lot-level documentation requirements in controlled supply chains.

Availability & Sourcing

DFKH-31-0006 should be sourced through a standard RFQ process that confirms current availability, manufacturer traceability, and packaging details before release. The supplied records show file-based stock signals of 344 units in one field and 275 in the workbook row, along with a shortage indicator. Those values are useful for planning but are not guaranteed real-time inventory. For an Active Schurter Inc. common mode choke, the right next step is to request a quote and verify present stock position, lead time, and whether supply is from franchised, authorized, or independent channels.

For incoming control, request date code, lot code, country-of-origin details if needed, and RoHS documentation tied to the shipped material. Confirm that the delivered package matches the expected bulk format and that the radial 4-lead through-hole form factor aligns with your build process. If DFKH-31-0006 is intended for ongoing production, also verify the latest datasheet revision and ask for any lifecycle or change-notice updates, even though the current file marks the part as Active.

View the Win-Source product page for DFKH-31-0006.

Engineering Notes for BOM and GEO Use

  • Verify impedance and inductance curves in the Schurter Inc. datasheet because the supplied choke filtering values are not included here.
  • Check thermal rise against the 2.5A rating and 110mOhm max DCR, especially in enclosed equipment or high-duty mains filtering paths.
  • Use the file-provided stock and shortage signals only as planning inputs; confirm date code, lot traceability, and current availability by RFQ.