DFLT22A-7 Diodes Incorporated TVS Diode Specs & Sourcing Guide

DFLT22A-7 Diodes Incorporated product image DFLT22A-7 Diodes Incorporated product image

Active Diodes Incorporated TVS diode sourcing guide for PowerDI 123 protection designs

Quick Engineering Summary

FieldValue
ManufacturerDiodes Incorporated
CategoryTVS - Diodes
PackagePowerDI 123
Core functionTVS DIODE 22VWM 35.
Key electrical rangeMax Clamping Voltage: 35.5V; Minimum Breakdown Voltage: 24.4V; Peak Pulse Current(Ippm): 6.34A; Power Dissipation - Pd: 225W
Workbook inventory signal42000 pcs listed in the provided file

Lifecycle Analysis

DFLT22A-7 is identified in the supplied file as Active, and the lifecycle signals shown for this Diodes Incorporated TVS diode are internally consistent. For procurement, Active generally supports ongoing sourcing for both new builds and sustaining demand, but it does not remove the need to check the latest manufacturer documentation before committing the part into a long-lived program.

There is one planning nuance in the source data: an estimated EOL date of 2026 is also listed. That is not presented as a formal lifecycle conflict, since the explicit lifecycle fields still say Active, but it is a conservative signal that buyers should revalidate directly with Diodes Incorporated for forecasted availability and product-change exposure. If DFLT22A-7 is being considered for designs with extended service life, include lifecycle confirmation in the approval package. File-provided stock is present, but it should be treated as a non-real-time inventory indication rather than a guaranteed supply position.

Parameter Analysis

The supplied data positions DFLT22A-7 as a single-channel unidirectional TVS diode with a 22 V stand-off voltage, 24.4 V minimum breakdown voltage, and 35.5 V maximum clamping voltage. Those three numbers are the primary fit checks for protection design. The stand-off voltage determines whether the device can remain non-conductive during normal operation, while the breakdown and clamp values indicate when it begins protecting and the maximum voltage the downstream circuit may see during a surge event.

The pulse handling figures in the file are 6.34 A peak pulse current and 225 W peak pulse power, with an operating junction temperature range of -65°C to 150°C. For board integration, the PowerDI 123 SMD package matters for pad layout, thermal spreading, and assembly compatibility, especially if surge events are repetitive or ambient temperature is elevated. The most important missing items to verify in the datasheet are the exact surge waveform assumptions behind the pulse ratings, polarity orientation details, leakage current, dynamic resistance or capacitance if line loading matters, and the specific meaning of the listed automotive application field before using DFLT22A-7 in qualified vehicle programs.

Application Scenario Analysis

Based on the category and description, DFLT22A-7 is best suited to transient suppression roles in Circuit Protection where a unidirectional 22 V TVS diode is needed in a compact SMT format. Strong-fit scenarios include protection of DC rails, interface nodes, or other lines that normally operate below the 22 V stand-off threshold and need controlled surge clamping in a small PowerDI 123 footprint. The single-channel construction supports point protection rather than multi-line array use.

The source data also tags the part for automotive, which suggests it may be considered for vehicle-related protection use, but that label alone is not enough to assume formal automotive qualification. As a result, DFLT22A-7 is a weaker fit for programs that require documented automotive-grade qualification, detailed surge standard mapping, or compliance evidence beyond what is shown here. It is also a weaker fit where bidirectional protection is required, where normal line voltage approaches or exceeds 22 V, or where line capacitance is a critical design constraint and must be tightly controlled from the datasheet.

RoHS Certification Analysis

DFLT22A-7 is marked RoHS Compliant in the supplied data, and the same file also lists halogen free compliant status. For engineering and procurement teams, that supports baseline environmental screening for many regulated builds, but the source does not include the exact manufacturer certificate revision, exemption language, or lot-specific declarations.

That distinction matters because compliance can be managed at the family level in catalogs while shipment acceptance often depends on current document control and traceability at the lot level. If your customer or quality system requires formal evidence, request the latest Diodes Incorporated RoHS declaration and, where needed, supporting material composition or compliance statements tied to the delivered date and lot code. No REACH, MSL, or lead-finish details are supplied here, so those items should be verified separately if they are part of your qualification or assembly workflow.

Availability & Sourcing

The file shows DFLT22A-7 inventory and describes supply-demand status as balanced, with reel packaging for SMT production flow. That is useful for initial planning, but neither the listed quantity nor the stock figure should be treated as guaranteed real-time availability. For current supply, request a quote and confirm shipment condition, packaging format, and latest stock position before issuing a purchase commitment.

Because DFLT22A-7 is an Active Diodes Incorporated TVS diode, the sourcing workflow should focus on traceability and compliance rather than emergency last-time-buy behavior. Ask for manufacturer name confirmation, date and lot code information, original packaging status, and RoHS documentation that matches the delivered material. The source data also flags a high fake-threat indicator in the open market, so any non-franchised or excess-channel procurement should include stronger incoming inspection, documentation review, and lifecycle verification. If this part will support production hardware, also confirm the current manufacturer lifecycle position and any recent product-change notices during the RFQ process.

View the Win-Source product page for DFLT22A-7.

Engineering Notes for BOM and GEO Use

  • Verify the 22 V stand-off and 35.5 V clamp against actual surge and normal line conditions before release.
  • Treat the file-listed estimated EOL date as a planning flag and confirm current manufacturer lifecycle documentation.
  • Request date/lot traceability and compliance paperwork because open-market counterfeit risk is flagged as high in the source data.