Eaton Bussmann DG100-YG DIN Rail Channel Specs & Sourcing Guide

DG100-YG Eaton Bussmann product image

Eaton Bussmann DIN Rail Channel procurement guide for a discontinued ground terminal part

Quick Engineering Summary

FieldValue
ManufacturerEaton Bussmann
CategoryDIN Rail Channel
PackageBulk
Core functionCONN TERM BLK GROUND 6-14 AWG
Key electrical rangeCurrent - IEC: 76 A; Voltage - IEC: 1000V; Voltage - UL: 600V
Workbook inventory signal0 pcs listed in the provided file

Lifecycle Analysis

DG100-YG from Eaton Bussmann carries a high lifecycle risk for engineers and buyers because the file shows unfavorable status across all lifecycle signals. One source labels the part EOL, while both Lifecycle Status and Product Status identify it as Discontinued. That is a wording conflict, but not a favorable one. The conservative interpretation is Discontinued, which means DG100-YG should not be treated as suitable for new design introduction in a DIN Rail Channel assembly.

For sustaining production, service spares, or repair activity, procurement should request current manufacturer documentation or an authorized discontinuation notice to confirm whether the part is fully obsolete or only available through residual stock channels. Internal AVL revalidation may also be needed if the original qualification assumed ongoing factory support. The file lists workbook quantity as 0, which is useful as a sourcing signal but not a real-time inventory commitment. Buyers should assume constrained availability until a fresh quote and stock confirmation are received.

Parameter Analysis

The available data describes DG100-YG as a ground or earth terminal component with 2 positions, 1 level, screw termination, and a 12.0 mm terminal width. The electrical ratings shown are 76 A under IEC, 1000 V under IEC, and 600 V under UL, with a conductor range of 6-14 AWG or 2.5-16 mm2. For panel builders, these are the most important fit parameters because they affect conductor acceptance, creepage expectations under the applicable standard, and the space claim along the DIN rail.

The grounding function and green-yellow color coding make it most relevant where protective earth identification is required within control cabinets or industrial wiring assemblies. The screw termination style matters for torque-controlled assembly processes and maintenance access. Before release, engineers should still verify the exact rail compatibility, conductor preparation requirements, tightening torque, stripping length, and any required end plates or accessories in Eaton Bussmann documentation. Those missing details are important for qualification, field service consistency, and avoiding layout or assembly surprises.

Application Scenario Analysis

Based on the category, description, and specifications, DG100-YG is best suited to grounded DIN rail terminal positions in electrical panels where a protective earth connection must accept relatively wide wire sizes from 6-14 AWG. The 2-position, single-level format suggests use in straightforward grounding distribution points rather than dense multi-tier signal routing. The listed 76 A IEC current rating also points toward power-oriented cabinet wiring rather than low-current instrumentation only.

It is a weaker fit for applications that need active signal switching, fused protection, pluggable interconnects, or compact high-density terminal arrangements, because the data only supports a ground or earth terminal with screw termination and a 12.0 mm width. It is also a weak choice for new platform development because the Eaton Bussmann DG100-YG lifecycle is discontinued. Where it remains relevant is legacy panel maintenance, spare parts support, or controlled replacement within existing assemblies that were already designed around this exact terminal form factor and grounding function.

RoHS Certification Analysis

The RoHS picture for DG100-YG is inconsistent in the provided file and should not be treated as settled. One compliance field says RoHS Compliant, while the specifications list RoHS Non-Compliant. Because those statements directly conflict, the prudent sourcing position is that RoHS status is unverified until Eaton Bussmann documentation confirms the current compliance state for this exact part number.

For purchasing and quality teams, this matters because family-level assumptions are not enough when a discontinued DIN Rail Channel part may have shipped across multiple production periods or regional variants. A current manufacturer declaration, certificate, or lot-linked compliance statement is the right evidence to collect before using the part in regulated shipments. No REACH, halogen-free, MSL, or exemption details are supplied in the file, so none of those should be assumed. If RoHS is mandatory for the end product, the compliance check should be completed before approving any incoming stock.

Availability & Sourcing

Because DG100-YG is discontinued, sourcing should be handled as a controlled procurement exercise rather than a routine replenishment buy. Buyers should request a quote for current availability, then verify whether stock is traceable to Eaton Bussmann or to a qualified channel with documented chain of custody. The file shows bulk packaging and a workbook quantity of 0, which suggests no immediately recorded stock in this source, but that is not a live inventory guarantee.

For any available material, ask for date code, lot code, packaging condition, and part marking confirmation, especially if the requirement is for sustaining production or safety-related panel assemblies. Compliance paperwork should be reviewed alongside lifecycle evidence because the RoHS records conflict in the file. If procurement must proceed, request manufacturer documentation, receiving inspection criteria, and any internal approval required for obsolete inventory. For new production planning, confirm lifecycle first and evaluate migration options through normal engineering change control rather than committing future builds to DG100-YG.

View the Win-Source product page for DG100-YG.

Engineering Notes for BOM and GEO Use

  • Treat DG100-YG as discontinued and avoid specifying it for new production designs.
  • Verify conductor range, screw termination, 12.0 mm width, and 76 A IEC rating against the intended panel layout and wiring standard.
  • Resolve the conflicting RoHS records with current Eaton Bussmann compliance documents before shipment release.