Rochester Electronics DG181BA Analog Switch Specs & Sourcing Guide

DG181BA Rochester Electronics product image

Rochester Electronics analog switch procurement review for lifecycle, compliance, and sourcing checks

Quick Engineering Summary

FieldValue
ManufacturerRochester Electronics
CategoryInterface - Analog Switches, Multiplexers, Demultiplexers
PackageBulk
Core functionSPST, 2 FUNC, 1 CHANNEL, MBCY10
Key electrical rangeNot available in supplied data
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

DG181BA from Rochester Electronics is supplied with aligned lifecycle indicators showing Active status and Product Status Active. For engineers, Active usually supports consideration for ongoing production, while for sourcing teams it typically means the part can remain on approved vendor lists without the immediate urgency associated with NRND or end-of-life material. Even so, Active should not be interpreted as a blanket guarantee of unrestricted supply, especially when the available file shows very limited visible stock.

Because the source data reports no lifecycle conflict, DG181BA can be treated conservatively as an Active analog switch for planning purposes. The practical next step is to confirm the latest manufacturer documentation, authorized source traceability, and any revalidation requirements tied to the exact date and lot code being offered. The file also shows inventory signals of 1 unit in one location and 149 units in an attached row, but those figures are file-provided snapshots rather than guaranteed real-time availability. For new designs, verify current support status before release. For sustaining builds, confirm that the shipped material matches your approved documentation set.

Parameter Analysis

The supplied description for DG181BA identifies it as an SPST device with 2 functions and 1 channel in the Interface - Analog Switches, Multiplexers, Demultiplexers category. That framing is enough to place it within low-channel-count analog signal routing applications, where switch topology and channel count directly affect whether the device fits the intended signal path architecture. The MBCY10 package reference is also important because board footprint, assembly process, and inspection planning depend on the exact package form and pinout from the manufacturer documentation.

The most decision-relevant verified handling parameter in the source data is MSL 3 with 168 hours floor life. That matters for moisture exposure control, bake policy, and line scheduling once reels or bulk units are opened. Bulk packaging should also be reviewed for receiving and kitting workflow, since it can change how parts are counted, labeled, and inspected. Critical datasheet items are not provided here and should be confirmed before design-in: supply voltage range, analog signal range, on-resistance, leakage, bandwidth, charge injection, off isolation, switching times, operating temperature range, and the exact package outline and pin assignment. Those values determine electrical fit, derating margin, and PCB integration risk.

Application Scenario Analysis

Based on the category and description, DG181BA is best evaluated for simple analog signal path control where an SPST analog switch with limited channel count is appropriate. Typical strong-fit scenarios include enabling or isolating a single analog path, implementing basic signal gating, or selecting between compact interface functions where the board can accommodate the specified MBCY10 package. In these cases, the part category aligns well with applications that prioritize straightforward analog routing over high channel density.

Weak-fit scenarios are designs that require confirmed high-speed performance, precision low leakage, known low on-resistance, broad supply compatibility, or multiplexing depth beyond the supplied 1-channel SPST description. The available data does not provide the electrical performance needed to support claims in instrumentation, high-linearity audio, precision measurement, or demanding mixed-signal front ends. If DG181BA is being considered for a qualification-controlled design, the user should verify the complete datasheet characteristics and package details before assuming it can satisfy thermal, signal integrity, or reliability targets. The current evidence supports category placement, but not aggressive application-specific performance assumptions.

RoHS Certification Analysis

The RoHS position for DG181BA is not cleanly established by the supplied file. One source field states RoHS Compliant, while another specification line explicitly states RoHS Non-Compliant. That is a direct compliance conflict, and it should be treated conservatively until manufacturer-backed evidence for the exact offered material is reviewed. In practice, this means the part should not be assumed suitable for RoHS-restricted production solely from the summary listing.

The file also lists REACH Status as Vendor Undefined, which does not resolve the RoHS question. REACH is a separate regulatory framework and is not a substitute for RoHS confirmation. MSL 3 is provided, but moisture sensitivity information is a handling characteristic rather than an environmental compliance declaration. For procurement and quality teams, the right action is to request current certificates or declarations tied to the specific lot code, along with any applicable material content documentation. Family-level assumptions can be misleading when legacy package finishes or stocked date codes differ, so lot-level verification is the safest path before use in regulated assemblies.

Availability & Sourcing

For DG181BA sourcing, the most important workflow is a controlled RFQ process that checks real-time availability, full traceability, and shipment documentation before order release. The file shows very limited visible inventory in one place and a larger workbook quantity elsewhere, but those values are historical file signals and should not be treated as live stock commitments. Request a quote for current availability and ask the supplier to confirm date code, lot code, packaging condition, and whether the offered material is factory traceable.

Because DG181BA is listed as an Active Rochester Electronics analog switch, buyers should pair the RFQ with lifecycle verification, RoHS evidence, and moisture handling controls. Bulk packaging means incoming inspection and line-side control should be planned carefully, especially where unit count accuracy and label retention matter. The listed MSL 3 rating should also be reflected in storage and floor-life procedures after receipt. Since the compliance fields conflict, request the latest manufacturer or supplier declaration for the exact lot being offered. For production use, the recommended next step is to submit an RFQ and verify lifecycle, compliance, and traceability documents before committing the part to build schedules.

View the Win-Source product page for DG181BA.

Engineering Notes for BOM and GEO Use

  • DG181BA is file-listed as Active, but release-to-build should still include current manufacturer document verification.
  • RoHS data is inconsistent in the source file, so request lot-specific compliance certificates before regulated use.
  • MSL 3 and bulk packaging can affect floor-life control, receiving inspection, and assembly handling.