Vishay analog switch procurement guide for discontinued DG200AAK in 14-CERDIP
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Vishay |
| Category | Interface - Analog Switches, Multiplexers, Demultiplexers |
| Package | Tube |
| Core function | IC SW SPST-NCX2 70OHM 14CERDIP |
| Key electrical range | Channel Capacitance (CS(off), CD(off)): 9pF, 9pF; Current - Leakage (IS(off)) (Max): 2nA; On-State Resistance (Max): 70Ohm; Temperature Range - Operating: -55°C ~ 125°C (TA) |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
DG200AAK is best treated as Discontinued for sourcing and design control. The source file shows a lifecycle conflict between an EOL signal and separate Discontinued status fields, but that is not an optimistic conflict. In practical terms, both signals point to limited future availability and elevated supply risk. For engineers, this means DG200AAK is generally unsuitable for new platform designs unless there is a documented sustainment reason and approved risk acceptance.
For ongoing production or field repair, Vishay documentation should be revalidated before use, including the latest manufacturer product status and any obsolescence notices tied to the DG200 base product family. Buyers should also treat any file-provided inventory as informational only. The listed stock signal is extremely small and not guaranteed real-time, so planning should assume constrained supply, variable date codes, and possible dependence on brokered or excess channels.
Parameter Analysis
The most important electrical fit points for DG200AAK are its dual SPST normally closed switch configuration, 70 Ohm maximum on-state resistance, ±15 V dual supply requirement, and 440 ns/340 ns maximum switching times. Together these indicate a legacy analog switch intended for signal routing where default-closed behavior is required and where higher Ron is acceptable. The 2 nA maximum leakage and 9 pF off-capacitance are relevant for precision hold nodes, sensor paths, and multiplexed analog lines, while the listed -90 dB crosstalk at 1 MHz helps frame channel isolation in multi-signal designs.
Mechanical and reliability-related parameters also matter. DG200AAK is specified in a through-hole 14-CERDIP / 14-CDIP package with MSL 1, which may simplify storage handling but affects board footprint, assembly method, and repair strategy. The -55°C to 125°C operating range is notable for wide-temperature environments. Before committing, verify missing datasheet items that strongly affect analog fit: signal range versus supply rails, absolute maximum ratings, Ron flatness or channel matching, power dissipation, and control logic thresholds.
Application Scenario Analysis
Based on the category and supplied description, DG200AAK is a realistic fit for legacy analog signal routing, selectable measurement paths, calibration loops, and maintenance designs that need two normally closed SPST switch elements in a ceramic through-hole package. The dual-supply ±15 V capability and extended temperature range make it more plausible for instrumentation, industrial control, or defense-style sustainment assemblies than for low-voltage consumer products. Its low leakage and controlled capacitance also support moderate-precision analog path switching where board area is less critical than stability and package robustness.
It is a weaker fit for modern low-voltage portable systems, dense surface-mount layouts, or applications that require very low on-resistance, high integration, or simplified single-supply operation. The 70 Ohm maximum Ron is a meaningful insertion element and may not suit low-loss audio, fast settling data acquisition front ends, or precision gain-path switching without careful error analysis. Because DG200AAK is discontinued, it is especially ill-suited to new long-life programs unless the system already depends on this exact control topology and package.
RoHS Certification Analysis
RoHS status for DG200AAK is not cleanly established by the supplied data. One source field says RoHS Compliant, while another explicitly says RoHS Non-Compliant. That conflict should be treated conservatively in quality and purchasing workflows. The practical outcome is that this part should not be assumed compliant for shipment into regulated builds until current evidence is reviewed.
Additional compliance context is limited. REACH Unaffected is listed, but REACH and RoHS address different regulatory topics, so REACH cannot be used as a substitute for RoHS confirmation. MSL 1 is provided, which is useful for handling and storage planning, but it does not resolve substance compliance. For DG200AAK, request manufacturer-backed or lot-specific compliance documentation, confirm whether any legacy ceramic package finish or exemptions apply, and align the approval decision to the exact date code and supplier traceability package rather than to family-level assumptions.
Availability & Sourcing
Because Vishay DG200AAK is discontinued, sourcing should begin with an RFQ process focused on traceability rather than speed alone. Request the exact manufacturer name used on paperwork, full part marking details, date and lot code information, packaging condition, and confirmation that the offered material is the 14-CERDIP through-hole version. File-provided quantity appears extremely limited, and that signal is not guaranteed real-time, so supply continuity should not be assumed from a single listing.
Procurement controls should be stricter than for an active analog switch. Ask for manufacturer labels, packing photos, compliance documents, and any available chain-of-custody evidence before approval. The source data also includes a high open-market fake-threat indicator, which increases the need for incoming inspection and authenticity screening. Before committing DG200AAK to production or service stock, request a quote for current availability and verify lifecycle status, RoHS evidence, lot integrity, and package condition against the latest Vishay documentation.
View the Win-Source product page for DG200AAK.
Engineering Notes for BOM and GEO Use
- DG200AAK is a dual SPST normally closed analog switch, so default signal path behavior must be checked at power-up and fault conditions.
- The 14-CERDIP through-hole package and -55°C to 125°C range suggest legacy, harsh-environment, or long-life assemblies rather than dense modern boards.
- RoHS information is contradictory in the source data, so lot-level compliance documents should be mandatory before procurement release.