Active Intersil analog switch review for engineering fit, compliance checks, and sourcing control
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Intersil |
| Category | Interface - Analog Switches, Multiplexers, Demultiplexers |
| Package | Bulk |
| Core function | IC SW SPST-NOX4 200OHM 16SOIC |
| Key electrical range | Channel Capacitance (CS(off), CD(off)): 5pF, 5pF; Current - Leakage (IS(off)) (Max): 5nA; On-State Resistance (Max): 200Ohm; Temperature Range - Operating: 0°C ~ 70°C |
| Workbook inventory signal | 10900 pcs listed in the provided file |
Lifecycle Analysis
DG201ACY is identified in the supplied data as Active, and the lifecycle signals are internally consistent across the listed fields. For procurement teams, that supports normal sourcing activity for both sustaining production and carefully reviewed new builds. For engineers, Active status reduces obsolescence risk compared with NRND or EOL parts, but it does not remove the need to confirm the exact manufacturer documentation set, package option, and compliance status tied to the orderable material.
Because this Intersil interface analog switch appears to be an older-style commercial temperature device, design teams should still revalidate fit against present requirements rather than assuming long-term continuity from lifecycle alone. The file also includes inventory quantities, which can help prioritize an RFQ, but those figures are file-provided only and should not be treated as guaranteed real-time availability. Before release to production, buyers should confirm the current product status, review any manufacturer change notices if available, and verify that DG201ACY remains suitable for the intended build window and quality plan.
Parameter Analysis
DG201ACY is described as a quad SPST normally open analog switch in a 16-SOIC surface-mount package. The most decision-relevant electrical figures in the supplied data are 200 Ohm maximum on-state resistance, 5 pF off-capacitance, 20 pC charge injection, 5 nA maximum off leakage, and crosstalk of -90 dB at 100 kHz. Together, these parameters point to a part intended for moderate-speed analog signal routing where leakage and channel isolation matter, but where a relatively high on-resistance may limit accuracy or bandwidth in low-level or heavily loaded signal paths.
The supply range of 15 V single or ±15 V dual is important for compatibility with legacy analog rails and signal swing requirements. Typical switching times of 480 ns on and 370 ns off are useful for control-timing review, while the 0°C to 70°C operating range is a significant qualification boundary for industrial or automotive-adjacent environments. The most important missing items to verify in the manufacturer datasheet are signal range versus supply rails, continuous current limits, power dissipation, channel matching, absolute maximum ratings, and any flatness or distortion characteristics needed for precision analog switching.
Application Scenario Analysis
Based on the category and description, DG201ACY is best aligned with general-purpose interface analog switch functions such as signal gating, source selection, and line isolation in systems that use multiple low-to-moderate frequency analog paths. The quad SPST normally open topology supports applications where independent channel control is more useful than a mux tree, such as test routing, sensor path enable control, or selective connection of analog nodes in laboratory, telecom, or legacy mixed-signal boards. The dual-supply capability also suggests usefulness in bipolar signal environments that cannot be handled by low-voltage logic-only switches.
The weaker-fit scenarios are precision or high-linearity paths that are sensitive to switch resistance, charge injection, or temperature variation, especially since the supplied on-resistance is 200 Ohm maximum and the operating range is limited to 0°C to 70°C. It may also be a poor fit for modern low-voltage systems that do not provide 15 V or ±15 V rails. If the design depends on low distortion, rail-to-rail analog range, or wide-temperature qualification, those points should be confirmed directly in the manufacturer documentation before selecting DG201ACY for production use.
RoHS Certification Analysis
The RoHS position for DG201ACY is not cleanly resolved in the supplied record. One compliance field states RoHS Compliant, while a specification entry states RoHS Non-Compliant. That conflict is material for both procurement and regulatory review, so the part should not be treated as definitively compliant without current supporting documents tied to the exact manufacturer part and delivery lot.
REACH is listed as Affected, but REACH information does not substitute for RoHS status. The supplied data also includes MSL 3 with a 168-hour floor life, which is relevant for assembly handling but not for environmental compliance. In practice, buyers should request the latest manufacturer compliance certificate or declaration, confirm whether any exemptions apply, and ensure that the documentation is specific to DG201ACY in the quoted package and finish. If internal policy requires lot-level evidence, family-level database status alone should not be used as the final compliance signoff.
Availability & Sourcing
For sourcing, DG201ACY should be handled as an Active Intersil interface analog switch with normal but disciplined verification steps. The file includes stock indicators, including a workbook quantity and stock quantity, which suggest availability interest, but these are not guaranteed real-time figures. The right next step is an RFQ that requests current availability, package condition, and shipment configuration, especially because the supplied packaging information indicates bulk rather than a tape-and-reel presentation.
Procurement teams should ask for date code, lot code, traceability to the original manufacturer, and confirmation of the exact 16-SOIC ordering format being supplied. Because MSL 3 is listed, receiving and floor-life controls should be checked if the material will enter assembly after extended storage or repackaging. Compliance documentation needs special attention because the RoHS records conflict, and lifecycle should still be reconfirmed at quote stage even though the supplied status is Active. Request a quote for current availability and include requirements for traceability, compliance evidence, and handling details before approving DG201ACY for production supply.
View the Win-Source product page for DG201ACY.
Engineering Notes for BOM and GEO Use
- Verify DG201ACY RoHS status directly from current manufacturer compliance documents because supplied records conflict.
- Check signal accuracy impact from 200 Ohm on-resistance, 20 pC charge injection, and 5 pF off-capacitance before reuse in precision paths.
- Confirm date code, lot traceability, MSL 3 handling, and bulk packaging suitability during RFQ review.