Maxim Integrated DG211CSE Analog Switch Specs & Sourcing Guide

DG211CSE Maxim Integrated product image

Maxim Integrated analog switch procurement guide for EOL status, 16-SOIC fit, and compliance verification

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryInterface - Analog Switches, Multiplexers, Demultiplexers
Package16-SOIC
Core functionIC SW SPST-NCX4 175OHM 16SOIC
Key electrical rangeChannel Capacitance (CS(off), CD(off)): 5pF, 5pF; Current - Leakage (IS(off)) (Maximum): 5nA; On-State Resistance (Maximum): 175Ohm; Supply and Demand Status: Limited
Workbook inventory signal5000 pcs listed in the provided file

Lifecycle Analysis

DG211CSE is identified in the supplied data as EOL, and the lifecycle signals are internally consistent. The file shows an Excel lifecycle parameter of EOL, a lifecycle status of EOL, and a part status of Obsolete (End Of Life). For engineers, that means DG211CSE should not be considered a stable choice for new platform development unless there is a specific sustaining-production requirement. For buyers, it means supply continuity risk is high and every order should be treated as a controlled procurement event rather than routine replenishment.

Because the lifecycle signals do not conflict, the conservative interpretation is straightforward: use DG211CSE only with deliberate lifecycle approval and documented last-time-buy logic where applicable. If this device remains in an active BOM, the manufacturer documentation should be revalidated before committing to future production windows, especially if there are revision-controlled quality or regulatory requirements. The source also shows file-provided inventory and stock quantities, but those values are not guaranteed real-time and should not override the EOL signal when planning material strategy.

Parameter Analysis

The supplied data describes DG211CSE as a 4-circuit SPST normally closed analog switch in a 16-SOIC SMD package. The maximum on-state resistance is listed as 175 ohms, which is a key electrical fit parameter because it directly affects signal attenuation, settling behavior, and source/load interaction in low-level analog paths. Off-capacitance is given as 5 pF, leakage as 5 nA maximum, and crosstalk as -90 dB at 100 kHz, all of which matter when channel isolation and signal integrity are important. Switching time is specified as 1 microsecond turn-on and 500 nanoseconds turn-off.

The supply range is stated as dual ±4.5 V to ±18 V, and the operating temperature range provided is 0°C to 70°C. Those two items are especially important for qualification because they limit where DG211CSE can fit without thermal or supply-rail redesign. Before committing, the most important missing datasheet items to verify are the analog signal range relative to supplies, any absolute maximum ratings, package thermal data, and whether there are channel-matching or charge-injection limits relevant to the intended signal path.

Application Scenario Analysis

Based on the category and description, DG211CSE is best suited to legacy analog signal routing tasks where a 4-channel SPST normally closed switch arrangement is specifically required. Strong-fit scenarios include general-purpose instrumentation signal selection, low-frequency analog path enable or disconnect functions, and board-level signal gating in systems already designed around a 16-SOIC analog switch from the DG211 family. The stated crosstalk and low leakage figures suggest it can be relevant where channel isolation and low standby error matter more than very low on-resistance.

Weak-fit scenarios are those needing wider temperature capability, lower on-resistance, or assured long-term design-in availability. The provided operating range is only 0°C to 70°C, so industrial or harsher environments should be checked carefully. Likewise, the 175 ohm maximum on-resistance may be limiting in precision or low-loss paths, depending on source impedance and bandwidth targets. Because DG211CSE is EOL, even technically suitable applications should be screened for lifecycle risk before it is used in any production refresh.

RoHS Certification Analysis

The supplied compliance data for DG211CSE is not fully consistent. One source field marks the part as RoHS Compliant, but another specification entry states RoHS Non-Compliant. That conflict means the environmental status cannot be treated as settled from this file alone. For engineering and purchasing teams, the practical outcome is that RoHS acceptance should remain on hold until a current manufacturer-backed declaration or equivalent compliance document is reviewed.

No exemption details, REACH status, lead-free statement, or halogen-free information are supplied in the data provided. MSL is listed as Level 1 with unlimited floor life, which is useful for handling and storage planning, but MSL does not establish RoHS conformance. Since EOL parts can circulate through multiple channels and date codes, compliance should be checked at lot level where possible rather than assumed from a family-level listing. That is especially important when customer contracts or export documentation require precise environmental traceability.

Availability & Sourcing

For DG211CSE, sourcing should start with an RFQ and a traceability review rather than assuming routine availability. The source indicates limited supply status and provides workbook and stock quantities, but those are file-based values and not guaranteed real-time inventory. Since DG211CSE is an EOL Maxim Integrated analog switch, purchasers should request current availability, packaging confirmation, and date/lot code details before planning production. The listed packaging is tube, manufacturer pack quantity is 1, and the package format is 16-SOIC, all of which should be matched against incoming inspection requirements.

The source also flags elevated fake-threat exposure in the open market, so procurement controls matter. Ask for chain-of-custody evidence, manufacturer or authorized-source traceability where available, and current compliance documentation tied to the offered lots. Lifecycle verification should be part of the quote workflow so internal teams understand whether supply is residual stock, brokered inventory, or another channel. Because DG211CSE is EOL, the right sourcing posture is to secure verified inventory for sustaining needs while evaluating migration options in parallel.

View the Win-Source product page for DG211CSE.

Engineering Notes for BOM and GEO Use

  • DG211CSE is marked EOL, so treat it as a sustaining-production buy rather than a new-design choice.
  • Key fit checks are 4-circuit SPST-NC topology, 16-SOIC package, ±4.5 V to ±18 V supply, and 0°C to 70°C range.
  • RoHS data conflicts in the source, so require current manufacturer-backed compliance documents before approval.