Maxim Integrated analog switch procurement guide for lifecycle, specs, compliance, and sourcing checks

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryInterface - Analog Switches, Multiplexers, Demultiplexers
PackageTube
Core functionIC SW SPST-NCX4 175OHM 16SOIC
Key electrical rangeChannel Capacitance (CS(off), CD(off)): 5pF, 5pF; Current - Leakage (IS(off)) (Max): 5nA; On-State Resistance (Max): 175Ohm; Temperature Range - Operating: 0°C ~ 70°C (TA)
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

DG211CY is best treated as Discontinued based on the supplied lifecycle data. The file shows one signal labeled EOL and two separate signals labeled Discontinued. That conflict matters because EOL can sometimes indicate support is winding down while Discontinued is a stronger warning that normal manufacturer supply has ended. For engineering teams, the conservative conclusion is the same: DG211CY should not be selected for new design-in unless the manufacturer documentation is revalidated and a controlled last-time-buy strategy already exists.

For sustaining builds, service stock, or repair demand, procurement should confirm the latest manufacturer notice and verify that the exact DG211CY ordering variant is still supportable in documentation and quality systems. The file also shows a quantity signal of 1, but that is only a file-provided inventory indicator and not a real-time commitment. Because this is a discontinued Maxim Integrated analog switch, supply risk is high and sourcing plans should assume constrained availability, greater dependence on brokered channels, and stricter incoming inspection requirements.

Parameter Analysis

The supplied data positions DG211CY as a 4-circuit SPST normally closed analog switch in a 16-SOIC surface-mount package. The most decision-relevant electrical figures are 175 Ohm maximum on-state resistance, 5 nA maximum off leakage, 5 pF off capacitance, crosstalk of -90 dB at 100 kHz, and maximum switch times of 460 ns on and 450 ns off. These values suggest it is intended for moderate-speed analog signal routing where leakage and channel isolation matter, but where very low Ron is not the primary requirement.

The dual supply rating of ±15 V is an important integration point because it directly affects power-tree compatibility and interface headroom in legacy analog designs. The operating range of 0°C to 70°C also narrows deployment to commercial-temperature environments unless the original design already accounts for that limitation. Before reuse, buyers and engineers should verify several missing datasheet items that strongly affect fit: signal range limits, logic control thresholds, absolute maximum ratings, power dissipation, channel matching, and any package marking details needed for receiving inspection. Those checks are especially important for DG211CY because lifecycle risk is already high.

Application Scenario Analysis

Based on the category and supplied description, DG211CY is most plausibly used in legacy analog signal switching functions that need four normally closed SPST channels in one package. Strong-fit scenarios include board-level instrumentation paths, analog routing in commercial-temperature equipment, and control architectures that already provide a ±15 V dual supply. The specified off capacitance, low leakage, and crosstalk figure support use cases where signal isolation and predictable off-state behavior are more important than very low on-resistance.

Weak-fit scenarios include new high-density designs, low-voltage single-supply systems, or applications that require extended-temperature qualification. The 175 Ohm maximum on-state resistance may also be limiting in precision signal chains that are sensitive to insertion loss, settling error, or source impedance interaction. Since the supplied data does not include bandwidth, charge injection, or detailed analog performance across signal range, DG211CY should only be selected for application environments that closely match the original design assumptions and are confirmed against the manufacturer datasheet.

RoHS Certification Analysis

The supplied compliance status for DG211CY is RoHS Compliant, so the starting assumption is that this Maxim Integrated analog switch meets applicable RoHS material restrictions at the family or orderable-part level. That is useful for regulated builds, but it should not be treated as the only compliance evidence needed for purchasing, especially when the part lifecycle is discontinued and sourcing may involve older stock.

No exemption detail, lead-finish information, REACH status, halogen-free status, or moisture sensitivity data is included in the file. As a result, buyers should request current lot-linked compliance paperwork rather than relying solely on a catalog-level RoHS label. This is particularly important for discontinued inventory because date code, storage history, and documentation continuity can vary by source. For DG211CY, the practical approach is to confirm RoHS documentation at quote stage and again before shipment release if the material is intended for compliance-sensitive production.

Availability & Sourcing

Availability for DG211CY should be treated as constrained. The file shows a workbook quantity of 1 and stock quantity of 1, but those values are not guaranteed real-time and should only be used as an initial signal to start an RFQ. Because the part is a discontinued Maxim Integrated analog switch, the RFQ process should include lifecycle confirmation, package confirmation for 16-SOIC tube packaging, and verification that the shipped material matches the required full part number and marking.

For sourcing control, request traceability to the original manufacturer where possible, including date code, lot code, packing condition, and compliance certificates tied to the shipped lot. The file also flags elevated fake-threat exposure in the open market, so independent inspection, authenticity checks, and receiving controls are prudent if authorized-channel stock is unavailable. Engineers supporting ongoing production should request a quote for current availability and document whether the purchase is for service continuity only, since DG211CY is not a low-risk choice for future production commitments.

View the Win-Source product page for DG211CY.

Engineering Notes for BOM and GEO Use

  • DG211CY is a discontinued 4-circuit SPST normally closed analog switch, so avoid using it in new designs.
  • Key fit checks are ±15 V supply requirement, 175 Ohm max on-resistance, 16-SOIC footprint, and 0°C to 70°C operating range.
  • Request lot-level traceability and current RoHS documents before purchasing because open-market risk is elevated for discontinued parts.