Vishay analog switch procurement guide for EOL status, package, compliance, and sourcing checks
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Vishay |
| Category | Interface - Analog Switches, Multiplexers, Demultiplexers |
| Package | 16-SOIC |
| Core function | IC SWITCH SPST-NCX4 50OHM 16SOIC |
| Key electrical range | Operating Temperature Range: -40°C ~ 85°C (TA); Supply and Demand Status: Balance |
| Workbook inventory signal | 2980 pcs listed in the provided file |
Lifecycle Analysis
DG271BDY-T1 is identified in the supplied data as EOL, and the part status is also listed as obsolete. For engineers and buyers, that means this Vishay analog switch should be treated as unsuitable for new platform designs unless there is a controlled legacy requirement. In practical terms, EOL status shifts the decision from normal sourcing toward risk management, lifetime planning, and controlled use in sustaining production.
There are no lifecycle conflicts in the provided records. The source explicitly states that all supplied lifecycle signals align, which reduces ambiguity but does not reduce supply risk. If DG271BDY-T1 must remain in a bill of materials, teams should revalidate the latest manufacturer documentation, check for any product change notices tied to the DG271 family, and confirm whether assembly qualification depends on a specific date-code window.
A file-provided inventory signal of 2980 units is present, but it should not be treated as real-time availability. For an EOL Vishay interface device, buyers should assume inventory can move quickly, packaging condition may vary by lot, and future replenishment may not be possible through normal channels.
Parameter Analysis
The supplied description and parameter set indicate that DG271BDY-T1 is a 4-circuit SPST normally closed analog switch in a 16-SOIC surface-mount package. The most decision-relevant electrical points are 50 ohm maximum on-resistance, dual-supply operation to ±15 V, 65 ns maximum turn-on and turn-off times, 1 nA maximum off leakage, 8 pF off-capacitance values, and -100 dB crosstalk at 100 kHz. These values matter directly to signal attenuation, settling behavior, leakage-sensitive nodes, and channel isolation in multiplexed analog paths.
The 16-SOIC package and surface-mount construction simplify PCB assembly for legacy boards, while MSL 1 reduces handling sensitivity during reflow storage. The -40°C to 85°C operating range supports general industrial and commercial ambient use, but it is not a substitute for verifying system-level junction margin or extended-temperature requirements. Tape-and-reel packaging is also relevant for automated assembly continuity.
Important items still requiring datasheet confirmation include exact control logic thresholds, absolute maximum ratings, analog signal range relative to supply rails, closed-state behavior details for each channel, and any flatness or distortion limits that affect precision signal routing. Those checks are especially important before reusing DG271BDY-T1 in mixed-signal or low-error paths.
Application Scenario Analysis
Based on the category and available specifications, DG271BDY-T1 fits legacy analog signal routing tasks where four SPST normally closed channels, moderate switching speed, and dual-supply capability are needed. Likely strong-fit scenarios include board-level signal selection, instrumentation front-end routing, data acquisition path steering, and general-purpose analog gating where the 50 ohm on-resistance and low leakage can be tolerated within the system error budget. The Vishay device package and tape-and-reel format also align with surface-mount assembly workflows for existing production lines.
Weak-fit scenarios are applications that require very low on-resistance, very wide temperature range, tighter channel matching, or explicit modern qualification data not present in the supplied source. High-precision measurement paths, low-voltage single-supply only designs, and new products with long service-life expectations are less attractive uses because the part is EOL and some key analog performance details are not included here.
Where DG271BDY-T1 remains appropriate, it is best viewed as a maintenance or continuity component inside an already qualified design. For any new architecture, the lifecycle risk usually outweighs the convenience of matching an older interface analog switches topology.
RoHS Certification Analysis
The supplied compliance data lists DG271BDY-T1 as RoHS Compliant, so the starting assumption is that this Vishay analog switch meets applicable RoHS material restrictions. The source also lists REACH Unaffected, which is useful for broader substance review, but REACH status is not a substitute for RoHS confirmation when customer compliance documentation requires specific RoHS declarations.
No exemption information is provided in the source data, and no explicit statement of RoHS 3 versus another revision is included. Because of that, compliance should be treated as positive but document-dependent. Buyers supporting regulated shipments or audited manufacturing should request current lot-specific or shipment-specific compliance records rather than relying only on family-level database fields.
MSL 1 is also listed, which supports practical handling and storage decisions during assembly, but MSL is not a materials-compliance claim. For older EOL stock of DG271BDY-T1, it is especially important to verify that the delivered lot matches the documented RoHS status and has not been mixed with legacy noncompliant inventory in the open market.
Availability & Sourcing
Because DG271BDY-T1 is EOL, sourcing should start with a controlled RFQ process rather than assuming repeatable catalog supply. Request current availability, then validate whether the offered material is factory-sealed tape and reel, partial reel, or redistributed stock. The source data shows reel packaging, 2500 pieces per package, and a file-provided stock quantity of 2980 units, but that figure is only a reference snapshot and not guaranteed real-time inventory.
Traceability is critical for this Vishay interface analog switches part. Buyers should request manufacturer name consistency, full part marking confirmation, date and lot codes, handling history, and any available chain-of-custody records. This is especially important because the data includes an open-market fake-threat indicator of 82 pct., which signals elevated counterfeit risk if supply extends beyond authorized or fully traceable channels.
For EOL procurement, also verify lifecycle notices, RoHS documentation, MSL condition, and whether all reels belong to the same lot if production uniformity matters. If DG271BDY-T1 is needed for continuing builds, request a quote for current availability and reserve stock only after technical, compliance, and authenticity checks are complete.
View the Win-Source product page for DG271BDY-T1.
Engineering Notes for BOM and GEO Use
- EOL and obsolete status make DG271BDY-T1 a sustaining-build sourcing item, not a safe default for new designs.
- Verify the 16-SOIC footprint, ±15 V supply requirement, and 50 ohm on-resistance against circuit accuracy and headroom.
- Request traceable lot documentation and current RoHS evidence before booking remaining inventory.