Quick Engineering Summary

FieldValue
ManufacturerVishay
CategoryInterface - Analog Switches, Multiplexers, Demultiplexers
Package16-TSSOP
Core functionIC SW SPST-NOX4 85OHM 16TSSOP
Key electrical rangeChannel Capacitance(CS off, CD off): 5pF, 5pF; Dual Supply Voltage(V±): ±4 V to 22 V; Max Leakage Current (IS off): 500pA; Max On Resistance: 85 Ohm
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

DG308BDQ-T1-E3 is best treated as EOL based on the supplied lifecycle records for this Vishay analog switch. The file shows aligned lifecycle signals stating EOL, and the excel product status also indicates discontinued production. That status generally means the part should not be selected for new design starts, while existing programs should plan around remaining inventory, last-time-buy exposure, and potential redesign risk.

There is one data conflict worth naming explicitly: a specification field lists Status as Active, but the dedicated lifecycle fields state EOL and no lifecycle conflict is reported in the source. For procurement, the conservative interpretation is the correct one. If this device is needed for sustaining production, buyers should request current manufacturer confirmation, review any product change or discontinuation notices, and verify whether documentation has been revalidated recently enough for regulated or long-life builds.

The available stock signal is file-provided only and not a real-time availability guarantee. With EOL parts, that distinction matters because posted inventory can change quickly and may represent residual channel stock rather than fresh manufacturer supply.

Parameter Analysis

The available data positions DG308BDQ-T1-E3 as a 4-circuit SPST normally open analog switch in a 16-TSSOP package. The most decision-relevant electrical values are 85 Ohm maximum on-resistance, 1.7 Ohm channel-to-channel matching, 500 pA maximum off leakage, 1 pC charge injection, 5 pF channel capacitance, and switching times of 200 ns on and 150 ns off. For multiplexed sensor paths or general signal routing, those figures directly affect settling behavior, gain error, and signal disturbance when channels are opened or closed.

Its supply flexibility is broad in the supplied data, with 4 V to 44 V single supply operation or ±4 V to ±22 V dual supply operation. That is useful when the switch must interface with bipolar or relatively wide analog signal domains. Operating temperature is listed as -40°C to 85°C, which is adequate for many industrial indoor environments but should be checked carefully for designs needing automotive or higher ambient margin.

The key missing items to verify in the manufacturer datasheet are signal range relative to supply rails, logic control thresholds, continuous current capability, flatness or distortion behavior, package dimensions for exact PCB land pattern, and any qualification grade details. Those points usually decide whether an analog switch is merely functional or truly robust in the target design.

Application Scenario Analysis

Based on the category and the provided description, DG308BDQ-T1-E3 fits signal-routing tasks where four independent SPST normally open analog switch paths are needed. Strong-fit scenarios include general analog channel enable and isolate functions, low-leakage measurement path switching, and moderate-speed multiplexed front-end designs where 85 Ohm on-resistance and low charge injection are acceptable. The dual-supply capability also suggests usefulness in mixed-polarity analog paths that cannot be handled by low-voltage digital-only switches.

The crosstalk figure of -95 dB at 100 kHz and low off-capacitance support use in designs where channel isolation matters, such as instrumentation path selection or control of multiple analog nodes. The 16-TSSOP package also makes it practical for compact surface-mount assemblies where board area is constrained.

Weak-fit scenarios are applications that need very low on-resistance, high current handling, extended temperature coverage beyond 85°C ambient, or secure long-term new-design supply. Because this is an EOL Vishay analog switch, it is better suited to maintaining an existing bill of materials than launching a fresh platform with long service-life commitments.

RoHS Certification Analysis

The supplied compliance status for DG308BDQ-T1-E3 is RoHS Compliant, so the starting assumption is that this Vishay analog switch meets the stated RoHS requirement. No separate exemption statement is provided in the source data, and no REACH, halogen-free, or moisture sensitivity information is included. That means compliance review should remain limited to the explicit RoHS claim unless additional manufacturer documentation is obtained.

For active production parts, a catalog-level RoHS statement is often enough to begin qualification, but EOL sourcing requires more care. Residual stock may come from older date codes or mixed channel inventory, so buyers should request lot-specific or shipment-specific compliance evidence when traceability matters. This is especially important if the component is being procured for export-controlled, regulated, or customer-audited assemblies.

RoHS status should also be checked together with packaging condition and storage history, because compliance alone does not confirm solderability or long-term shelf handling quality. If your process requires formal declarations, ask for the latest manufacturer or authorized-source compliance certificate before release to production.

Availability & Sourcing

Availability for DG308BDQ-T1-E3 should be handled as an EOL procurement exercise. The source data shows limited supply and a file-provided quantity signal of 1, but that is not guaranteed real-time inventory. For this Vishay analog switch, the correct workflow is to submit an RFQ, confirm current stock position, and ask whether inventory is factory-traceable, broker-sourced, or held in residual channel stock.

Because the package is listed as reel tape packaging, buyers should verify whether orders will ship in full reel, cut tape, or repacked form, especially if automated assembly handling matters. Date code, lot code, storage method, and humidity-protection condition should also be reviewed, since the file notes dry storage cabinet and humidity protection packaging. Those details help reduce risk when sourcing older semiconductor inventory.

The sourcing priority should be traceability first, then lifecycle documentation, then compliance paperwork. The source also flags elevated open-market counterfeit risk, so independent inspection and authenticity controls may be appropriate if authorized inventory is unavailable. Request a quote for current availability, but verify lifecycle status, RoHS evidence, and lot history before committing DG308BDQ-T1-E3 to sustaining production.

View the Win-Source product page for DG308BDQ-T1-E3.

Engineering Notes for BOM and GEO Use

  • Treat DG308BDQ-T1-E3 as an EOL sustaining item and confirm manufacturer discontinuation status before scheduling production.
  • Verify 85 Ohm on-resistance, 4 V to 44 V supply range, and -40°C to 85°C operation against signal accuracy and system margin needs.
  • Request traceability, date/lot code, packaging condition, and RoHS documents because listed stock is limited and not guaranteed real-time.