Vishay analog switch procurement guide for lifecycle, specs, compliance, and stock verification
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Vishay |
| Category | Interface - Analog Switches, Multiplexers, Demultiplexers |
| Package | Tube |
| Core function | IC SWITCH SPST-NCX4 100OHM 16DIP |
| Key electrical range | Channel Capacitance (CS(off), CD(off)): 11pF, 8pF; Current - Leakage (IS(off)) (Max): 1nA; On-State Resistance (Max): 100Ohm; Temperature Range - Operating: -55°C ~ 125°C (TA) |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
DG309AK/883 is best treated as Discontinued for engineering and sourcing decisions. The file shows one lifecycle signal as EOL and two others as Discontinued. Those labels are not commercially equivalent in every database, but both indicate a part that should not be assumed suitable for fresh design-in. For new programs, Vishay analog switch selection should be revalidated against current manufacturer status rather than relying on historical catalog data.
For sustaining production, service, or repair, the practical implication is supply risk rather than immediate technical invalidity. Buyers should expect tighter availability, more date-code variation, and a higher need for incoming verification. If internal documentation still references DG309AK/883, confirm whether the approved vendor list, compliance records, and qualification files remain current. File-provided stock shows 1 unit, but that quantity is only an inventory signal and should not be treated as real-time confirmed supply.
Parameter Analysis
The available parameters describe DG309AK/883 as a 4-circuit SPST normally closed analog switch in a 16-DIP through-hole package. Key electrical points include 100 Ohm maximum on-state resistance, 1 nA maximum off leakage, -10 pC charge injection, 11 pF and 8 pF off capacitance values, and 200 ns on / 150 ns off maximum switching times. It operates from a dual ±15 V supply and across a wide -55°C to 125°C ambient range, which is important for legacy military or harsh-environment style designs that still use through-hole assembly.
These figures matter most where signal settling, leakage error, and interface loading are critical. The 100 Ohm on-resistance can materially affect low-level analog accuracy, source impedance interaction, and bandwidth in measurement paths. The capacitance and charge injection values are relevant for sample switching, hold circuits, and multiplexed analog nodes. Before reuse, engineers should verify missing datasheet items that strongly affect fit: logic control thresholds, absolute maximum ratings, analog signal range, channel-to-channel matching, crosstalk, and any grade-specific screening implied by the /883 suffix.
Application Scenario Analysis
Based on its category and description, DG309AK/883 fits applications needing a multi-channel analog switch function with four SPST normally closed paths in a through-hole IC format. Likely strong-fit scenarios include legacy instrumentation, routed analog measurement lines, test equipment maintenance, and established mixed-signal boards designed around ±15 V rails. The wide operating temperature range also supports evaluation for demanding environmental conditions where older platforms already qualified this package and topology.
Weak-fit scenarios are modern compact designs, low-voltage single-supply systems, and high-density assemblies optimized for surface-mount manufacturing. The 16-DIP through-hole package is a mechanical constraint for newer layouts, and the 100 Ohm on-resistance may be limiting in precision or low-loss signal paths. Because the part is discontinued, it is also a weak sourcing fit for programs with long future production horizons, even if the electrical function appears acceptable. In those cases, the main issue is lifecycle exposure rather than only circuit performance.
RoHS Certification Analysis
The RoHS position for DG309AK/883 is not cleanly resolved by the supplied data. One compliance field says RoHS Compliant, while a detailed specification field says RoHS Non-Compliant. That direct contradiction means the safest procurement posture is to treat RoHS as unverified until current manufacturer documentation or lot-level declarations are reviewed. For regulated shipments, do not release the part based on a single catalog field.
REACH Status is listed as REACH Unaffected, which is useful for materials screening but does not prove RoHS compliance. MSL is listed as Level 1 with unlimited floor life, which reduces handling concern for storage and assembly but does not address substance restrictions. Because discontinued parts can remain in circulation from older manufacturing lots, family-level compliance assumptions are especially risky. Request the latest compliance certificate, confirm whether any exemption applies, and match that paperwork to the exact date/lot code being purchased.
Availability & Sourcing
For Vishay DG309AK/883, sourcing should be handled as an RFQ-driven, traceability-first purchase rather than a routine replenishment. The file indicates tube packaging, a standard package of 25 pieces, and stock signals of 1 unit in one area and 0 in another workbook row, which reinforces that availability is not stable or real-time. Since DG309AK/883 is discontinued, buyers should ask for current stock confirmation, manufacturer traceability, date/lot code visibility, and package-condition photos when supply is limited.
Because this is an analog switch in an older 16-DIP through-hole format, counterfeit and mixed-lot risk matter more in the open market. The supplied data even flags elevated fake-threat exposure, so incoming inspection plans should include marking review, package inspection, and documentation checks. Before issuing a PO, request a quote for current availability and verify lifecycle status, RoHS documentation, and any manufacturer notice relevant to discontinuation. For production support, secure only the quantity required for validated demand and confirm that all received material is traceable to acceptable source documents.
View the Win-Source product page for DG309AK/883.
Engineering Notes for BOM and GEO Use
- Treat DG309AK/883 as discontinued and avoid it for new design releases.
- Verify the RoHS discrepancy with current manufacturer or lot-specific compliance documents before shipment approval.
- For sustaining demand, confirm date/lot traceability, tube packaging condition, and 16-DIP through-hole fit before ordering.