Harris Corporation analog switch procurement guide for lifecycle, specs, compliance, and sourcing checks
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Harris Corporation |
| Category | Interface - Analog Switches, Multiplexers, Demultiplexers |
| Package | Bulk |
| Core function | IC SW SPST-NCX2 45OHM 16CERDIP |
| Key electrical range | Channel Capacitance (CS(off), CD(off)): 12pF, 12pF; Current - Leakage (IS(off)) (Max): 500pA; On-State Resistance (Max): 45Ohm; Temperature Range - Operating: -55°C ~ 125°C |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
DG401AK/883 is shown as Active in all supplied lifecycle fields, including the lifecycle status and product status entries. For engineers and buyers, an Active status generally means the Harris Corporation analog switch remains a viable procurement target for current production and maintenance demand, rather than being restricted to aftermarket recovery. Since the signals are aligned and no lifecycle conflict is listed, the immediate lifecycle risk is comparatively low.
Even with an Active status, good sourcing practice is to confirm current manufacturer documentation before placing this part into a long-duration design. That is especially relevant here because DG401AK/883 is a ceramic packaged interface device with an /883 suffix, where users may care about screening flow, documentation continuity, and exact ordering identity. The file also shows inventory signals, but those are file-provided only and should not be treated as guaranteed real-time availability. For new builds, request a quote and confirm latest lifecycle status, while for sustaining programs, validate that the shipped lot matches required documentation and handling expectations.
Parameter Analysis
The supplied data describes DG401AK/883 as a dual SPST normally closed analog switch in a 16-CERDIP through-hole package. The most decision-relevant electrical points are 45 Ohm maximum on-state resistance, 3 Ohm channel-to-channel Ron matching, 150 ns maximum turn-on time, 100 ns maximum turn-off time, 12 pF off capacitance, 60 pC charge injection, and 500 pA maximum off leakage. These values matter in signal-path designs because Ron affects insertion loss and DC error, charge injection can disturb sampled or high-impedance nodes, and off capacitance influences feedthrough and bandwidth behavior.
Supply flexibility is also significant. The part supports 5 V to 34 V single-supply operation or ±5 V to ±17 V dual supplies, and the operating temperature range is -55°C to 125°C. That combination can be useful where analog rails vary across platforms or where environmental margin matters. Before release, the most important missing items to verify in the datasheet are logic control thresholds, absolute maximum ratings, analog signal range relative to supply rails, current handling, and any package-specific thermal or screening notes. Buyers should also confirm whether the exact DG401AK/883 ordering version carries any additional qualification requirements beyond the basic analog switch specifications.
Application Scenario Analysis
Based on the category, description, and available electrical data, DG401AK/883 is best suited to general analog signal routing where a dual SPST normally closed topology is desired and through-hole ceramic packaging is acceptable. The wide supply range and extended temperature capability suggest fit for instrumentation interfaces, legacy mixed-signal control assemblies, and maintenance-driven hardware that needs an analog switch rather than a digital bus component. Low leakage and defined channel matching can also be relevant in precision paths where predictable off-state behavior matters.
The part is a weaker fit for space-constrained modern boards, high-density surface-mount layouts, or applications that require very low Ron, very low charge injection, or explicitly documented high-bandwidth switching performance. Its 45 Ohm maximum on-resistance and 12 pF off capacitance may be acceptable in many control and signal selection functions, but could be limiting in lower-loss or higher-frequency analog paths. Because only a limited set of parameters is supplied, engineers should verify the intended signal amplitude, source impedance, and control interface requirements before selecting DG401AK/883 for sensitive acquisition or precision switching tasks.
RoHS Certification Analysis
The supplied compliance record for DG401AK/883 is inconsistent. One top-level field states RoHS Compliant, but a detailed specification entry states RoHS Non-Compliant. Because these statements conflict, the prudent interpretation is that RoHS status is not yet verified for the exact Harris Corporation analog switch being sourced. In addition, REACH status is listed as Vendor Undefined, so there is no secondary environmental declaration in the file that resolves the conflict.
For procurement, this means compliance should be confirmed at the lot or manufacturer-document level rather than assumed from a family-level database flag. If your build requires formal environmental documentation, request the current RoHS declaration, material statement if available, and confirmation that the shipped finish and package construction match the declaration. The file also lists MSL 3 with a 168-hour floor life, which is a handling consideration but not a substitute for RoHS evidence. Until documentation is reviewed, treat the compliance state of DG401AK/883 conservatively.
Availability & Sourcing
For sourcing DG401AK/883, start with an RFQ process that asks for current availability, manufacturer traceability, date code, lot code, and packaging confirmation. The supplied record shows bulk packaging, a standard package of 38 pieces, and file-provided quantity signals including stock quantity 1 and a workbook quantity entry. These numbers are useful as sourcing indicators only and should not be treated as real-time inventory without supplier confirmation.
Because this Harris Corporation analog switch is listed as Active, the right procurement approach is to request a quote, verify lifecycle status, and confirm compliance documents before booking production demand. For higher-assurance programs, also request documentation that ties the shipped lot to the exact part marking and package style, especially for the 16-CERDIP form factor. The record also flags elevated open-market counterfeit exposure, so if supply extends beyond authorized or well-controlled channels, strengthen incoming inspection and traceability requirements. Before shipment release, confirm RoHS status, MSL handling expectations, and whether the delivered DG401AK/883 matches all program-specific documentation needs.
View the Win-Source product page for DG401AK/883.
Engineering Notes for BOM and GEO Use
- Verify RoHS status at lot level because the supplied record contains conflicting compliance fields.
- Check control logic thresholds and signal range limits in the datasheet before using DG401AK/883 in new designs.
- Treat listed stock as non-real-time and request date, lot, and traceability documents with the RFQ.