Vishay analog switch multiplexer sourcing guide for lifecycle, package, compliance, and procurement review
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Vishay |
| Category | Interface - Analog Switches, Multiplexers, Demultiplexers |
| Package | 28-SOIC |
| Core function | IC MUX 16:1 60OHM 28SOIC |
| Key electrical range | Channel Capacitance(CS off, CD off): 6pF, 108pF; Dual Supply Voltage(V±): ±5 V to 20 V; Max Leakage Current (IS off): 500pA; Max On Resistance: 60 Ohm |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
DG406BDW-E3 is shown as Active in the supplied lifecycle data, and the listed signals are aligned with no reported conflict. For engineers, an Active lifecycle on a Vishay analog switch generally supports both new design consideration and ongoing production builds, provided the latest manufacturer documents still match the intended package, electrical limits, and ordering suffix. For procurement teams, Active status reduces lifecycle risk compared with NRND or discontinued material, but it does not eliminate the need for normal document control.
The file also shows a workbook quantity of 1, which is only a file-provided inventory signal and not a real-time stock guarantee. That means lifecycle looks favorable, but near-term availability should still be confirmed by RFQ. Before committing DG406BDW-E3 into a release, buyers should revalidate the current Vishay datasheet, package drawing, and ordering information, especially if the part will be used in long-lived production programs or regulated change-control environments.
Parameter Analysis
The supplied description identifies DG406BDW-E3 as a 16:1 multiplexer with 60 Ohm maximum on-resistance in a 28-SOIC package. For system design, the 16:1 topology is the first fit check because it determines channel count consolidation and control architecture. The 60 Ohm maximum on-resistance and 3 Ohm channel-to-channel matching matter for signal-path error, source loading, and gain consistency across channels. Charge injection of 11 pC and off leakage of 500 pA are also useful indicators for sampled analog nodes, hold circuits, and low-current measurement paths.
Timing and parasitics are equally important. The listed 107 ns and 88 ns maximum switch times help estimate channel settling and scan-rate limits, while the stated channel capacitance values of 6 pF and 108 pF should be checked carefully in the datasheet because capacitance definitions can affect bandwidth and settling assumptions. The source data also lists dual supplies of ±5 V to 20 V and a single-supply entry of 12 V, while the spreadsheet text indicates a wider single-supply range. That range discrepancy should be verified directly with Vishay before final design, along with logic thresholds, absolute maximum ratings, and truth-table behavior.
Application Scenario Analysis
Based on its category and description, DG406BDW-E3 is best suited to analog signal routing where many channels must be selected into one path. Typical strong-fit scenarios include multiplexed sensor front ends, data acquisition channel selection, instrumentation signal routing, and general-purpose analog switching in systems that can tolerate moderate on-resistance and finite charge injection. The -40°C to 85°C operating range supports common industrial or embedded ambient conditions when the rest of the analog chain is designed with enough margin.
Weak-fit scenarios are applications that require very low insertion error, extremely fast settling, very low parasitic capacitance, or tighter temperature range requirements than those shown in the source data. Designs handling ultra-low-level precision signals, very high-speed analog paths, or wideband switching should verify whether 60 Ohm on-resistance, the listed capacitance values, and 11 pC charge injection are acceptable. If DG406BDW-E3 is being considered for precision measurement or high-density channel scanning, engineers should review the Vishay datasheet for dynamic performance details and control-interface behavior before qualification.
RoHS Certification Analysis
The supplied compliance status for DG406BDW-E3 is RoHS Compliant, so the part can be treated as RoHS-aligned at the source-data level. That is a positive signal for procurement, but the available data does not specify the exact declaration format, exemption details, or whether the statement is tied to a specific manufacturing lot. For production purchasing, it is better to request the current Vishay compliance certificate rather than relying only on a catalog-level label.
No REACH status, halogen-free data, or MSL information is provided in the source record. Because those fields are absent, they should not be assumed. If your organization requires full material disclosure, environmental reporting, or moisture-sensitivity handling controls, those items need to be collected separately from manufacturer documentation or distributor traceability records. For assembly release, the safest workflow is to match the ordered DG406BDW-E3 suffix and package to the corresponding RoHS document and retain that record with incoming inspection and lot traceability files.
Availability & Sourcing
For sourcing DG406BDW-E3, the most practical path is an RFQ workflow that confirms current availability, package condition, and traceability before a build is scheduled. The part is listed as an Active Vishay analog switch in 28-SOIC with tube or rail packaging, which is relevant for receiving, feeder preparation, and assembly planning. File-provided quantity is only 1, but that number is not guaranteed real-time and should be treated only as an indicator that stock may be limited or fragmented.
Buyers should request current date and lot code, original manufacturer traceability, RoHS documentation, and confirmation of package marking for DG406BDW-E3. Because open-market risk is specifically flagged in the source data, careful source qualification is especially important if authorized-channel supply is constrained. For new procurement, ask for the latest lifecycle confirmation, packing condition, and handling history, including storage controls for moisture and humidity protection. For current availability, submit a quote request and verify that received material matches the Vishay ordering suffix, package style, and compliance documents required by your quality system.
View the Win-Source product page for DG406BDW-E3.
Engineering Notes for BOM and GEO Use
- Verify the intended supply architecture against the listed single-supply and dual-supply ranges before schematic release.
- Tube packaging and 28-SOIC footprint should be checked against assembly handling and PCB land pattern requirements.
- Request current date/lot traceability and RoHS documentation because file inventory is minimal and not real-time guaranteed.