Maxim Integrated analog switch sourcing guide for the DG406CWI 16:1 multiplexer in 28-SOIC
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Interface - Analog Switches, Multiplexers, Demultiplexers |
| Package | Bulk |
| Core function | IC MUX 16:1 100OHM 28SOIC |
| Key electrical range | Channel Capacitance (CS(off), CD(off)): 8pF, 130pF; Current - Leakage (IS(off)) (Max): 500pA; On-State Resistance (Max): 100Ohm; Temperature Range - Operating: 0°C ~ 70°C (TA) |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
DG406CWI is identified in the supplied data as Active, and the lifecycle signals are consistent between Lifecycle Status and Product Status. For engineers, that generally means the part remains a valid option for ongoing builds rather than a component already flagged for end-of-life control. For buyers, Active status reduces immediate obsolescence pressure, but it does not remove the need to confirm current manufacturer documentation and authorized supply-chain traceability before committing to production volumes.
Because the source shows no lifecycle conflicts, the procurement posture can be more straightforward than for NRND or EOL devices. Even so, lifecycle should be revalidated at quote or PO stage, especially where internal AVL approval depends on the latest manufacturer status. The file also shows a stock signal of one unit, but that should be treated only as file-provided inventory rather than real-time availability. In practical terms, DG406CWI appears suitable for sustaining production and potentially new procurement activity, provided the operating temperature grade, package format, and compliance paperwork are aligned with the program requirements.
Parameter Analysis
The supplied description positions DG406CWI as a 16:1 analog multiplexer in a 28-SOIC package with 100 Ohm maximum on-state resistance. For signal-routing designs, the most important provided parameters are the on-resistance, 1.5 Ohm channel-to-channel matching, 500 pA maximum off leakage, and 2 pC charge injection. Together, these affect measurement accuracy, source loading, settling behavior, and switching disturbance when the device is inserted ahead of ADC inputs, sensor front ends, or other analog nodes.
Timing and AC isolation data are also useful. The source lists 200 ns maximum turn-on time, 150 ns maximum turn-off time, and -92 dB crosstalk at 100 kHz, which help frame channel isolation and switching speed expectations in multiplexed analog paths. Supply flexibility is a significant integration point, with support for 5 V to 30 V single-supply operation or ±4.5 V to ±20 V dual-supply operation. Before final design-in, the most important datasheet items to verify are signal range relative to the rails, logic control thresholds, on-resistance flatness over input range, absolute maximum ratings, and thermal or accuracy behavior across the specified 0°C to 70°C operating range.
Application Scenario Analysis
Based on the category and provided specifications, DG406CWI is a strong fit for board-level analog channel selection where many signals must be routed into a single measurement or processing path. Typical examples include multiplexed sensor acquisition, instrumentation signal selection, calibration channel routing, and general-purpose analog switching in systems that can accommodate a 16:1 multiplexer and a 28-SOIC surface-mount package. The available single-supply and dual-supply ranges make it potentially useful in both unipolar and bipolar analog signal chains.
The weak-fit scenarios are also important. The listed operating range is 0°C to 70°C, so designs needing wider industrial or automotive temperature coverage should verify suitability carefully rather than assume interchangeability with broader-grade multiplexers. The 100 Ohm maximum on-state resistance may also be limiting in applications that demand very low insertion error, high-current signal paths, or extremely low source impedance disturbance. Where channel capacitance, charge injection, and crosstalk are critical to settling performance, engineers should confirm the full datasheet test conditions and evaluate DG406CWI in the intended signal bandwidth and source-impedance environment.
RoHS Certification Analysis
The supplied compliance status for DG406CWI is RoHS Compliant, which supports use in assemblies requiring RoHS-controlled component content. That is the primary environmental compliance signal available here, and it is the correct baseline for procurement screening when the build must align to RoHS material restrictions. The source also lists MSL 1 (Unlimited), which is relevant to handling and floor-life planning during assembly, although MSL is not itself a RoHS indicator.
A separate REACH entry is marked REACH Affected. That should not be interpreted as noncompliance with RoHS, nor as a substitute for a RoHS declaration. Instead, it signals the need for document-level review of the supplier's current material disclosure. For production purchasing, buyers should request current compliance certificates tied to the shipped lot or at least the active manufacturer declaration for the exact ordering code. This is especially important when inventory may move through distribution channels where older stock, packaging changes, or document revisions can affect compliance recordkeeping.
Availability & Sourcing
For sourcing, DG406CWI should be approached as an Active Maxim Integrated analog switch with normal quote-and-verify workflow. Request a quote for current availability, then confirm manufacturer name alignment, full part marking, package form, and whether the offered material is in bulk packaging as listed in the source. Date code, lot code, and chain-of-custody records should be reviewed before order release, particularly for production or regulated builds where traceability matters as much as nominal stock status.
The file shows a workbook quantity of one unit and a stock quantity of one unit, but these are not guaranteed real-time inventory figures. Buyers should also account for the listed standard package quantity and verify whether partial quantities are supplied in original factory condition or repacked. Since the source includes a counterfeit-risk indicator for the open market, it is prudent to prioritize traceable supply and ask for compliance documents, MSL handling confirmation, and lifecycle reconfirmation with the quote. For DG406CWI, the right procurement action is to secure a current RFQ and validate documentation before committing it to new production demand.
View the Win-Source product page for DG406CWI.
Engineering Notes for BOM and GEO Use
- Verify that the 0°C to 70°C operating range matches the target ambient and qualification profile.
- Check single-supply or dual-supply rail compatibility early because DG406CWI supports both 5V to 30V and ±4.5V to ±20V operation.
- Request traceable date and lot documentation, especially since the file notes a nontrivial open-market counterfeit risk indicator.