Vishay analog switch procurement guide for discontinued through-hole 16-PDIP inventory
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Vishay |
| Category | Interface - Analog Switches, Multiplexers, Demultiplexers |
| Package | Tube |
| Core function | IC SWITCH SPST-NOX4 35OHM 16DIP |
| Key electrical range | Channel Capacitance (CS(off), CD(off)): 12pF, 12pF; Current - Leakage (IS(off)) (Max): 250pA; On-State Resistance (Max): 35Ohm; Temperature Range - Operating: -40°C ~ 85°C (TA) |
| Workbook inventory signal | 5930 pcs listed in the provided file |
Lifecycle Analysis
DG412HSDJ is best treated as Discontinued based on the available Vishay lifecycle data for this analog switch category. The source shows an explicit conflict between an Excel lifecycle parameter marked EOL and product-level fields marked Discontinued. In practice, that is not a favorable conflict for buyers because both signals point to end-of-life conditions rather than ongoing production support. For new designs, the conservative position is to avoid qualification on DG412HSDJ unless there is a documented sustaining requirement.
For existing equipment support, a discontinued status does not automatically mean no stock exists, but it does change the sourcing workflow. Buyers should confirm whether any remaining inventory is original and traceable, and whether the manufacturer has issued product change or discontinuation notices relevant to long-term service builds. File-provided inventory is listed, but that quantity is not guaranteed real-time. Because this Vishay interface analog switch is not in an active lifecycle state, procurement teams should plan around stock exhaustion risk, revalidation needs, and tighter incoming inspection controls.
Parameter Analysis
The supplied parameters describe DG412HSDJ as a 4-circuit SPST normally open analog switch in a 16-PDIP through-hole package. The maximum on-state resistance of 35 ohms is one of the first values to check against signal-path error budget, especially where source impedance, settling time, or gain accuracy matters. The listed 105 ns turn-on and 80 ns turn-off times are relevant for timing margin in multiplexed or gated analog paths, while 22 pC charge injection and 12 pF off capacitance matter for hold-step error, feedthrough behavior, and small-signal integrity.
Leakage is listed at 250 pA maximum, which is useful for high-impedance interfaces, and crosstalk is given as -88 dB at 1 MHz, indicating attention to channel isolation in multi-channel switching applications. Supply flexibility is broad, with 13 V to 44 V single supply or ±5 V to ±20 V dual supply, so designers must verify the exact intended rail configuration and logic-drive compatibility in the manufacturer datasheet. Important missing checks include bandwidth, analog signal range relative to rails, logic threshold details, and any on-resistance flatness data needed for precision applications.
Application Scenario Analysis
Based on the category and published specs, DG412HSDJ fits legacy analog signal routing tasks where a through-hole Vishay analog switch is preferred and board area is less constrained. Strong-fit scenarios include multiplexed instrumentation paths, signal gating, channel selection, and general-purpose analog routing in systems that can tolerate a 35 ohm on resistance and operate within the stated temperature and supply ranges. The 4-circuit SPST normally open arrangement is suitable when independent channel control is needed rather than a single mux tree.
Weak-fit scenarios include new compact designs that prioritize surface-mount assembly, applications requiring very low on resistance, or systems needing operating temperatures beyond 85°C ambient. Designs highly sensitive to charge injection, parasitic capacitance, or package size should review whether the 22 pC and 12 pF figures are acceptable at the system level. Because DG412HSDJ is discontinued, it is most realistic for maintenance, repair, and support of installed platforms rather than fresh design-ins where lifecycle continuity is a primary requirement.
RoHS Certification Analysis
DG412HSDJ is listed as RoHS Compliant, so the baseline compliance position for this Vishay analog switch is favorable for RoHS-managed procurement. The source also lists REACH Unaffected, which is useful supporting information but should not be treated as a substitute for RoHS status. No lead-free substatement, exemption detail, or material declaration reference is included in the provided data, so those documents should be requested if your quality system requires file-backed evidence.
The source also gives MSL 1 with unlimited floor life, which reduces handling concern compared with more moisture-sensitive packages, although MSL is separate from environmental compliance. For discontinued parts in particular, buyers should confirm that compliance documentation applies to the actual shipped lot and not only to the product family record. That is especially important when sourcing older tube-packaged through-hole inventory, where date code and warehouse history may affect the internal approval process even when the catalog RoHS field is compliant.
Availability & Sourcing
For DG412HSDJ, sourcing should start with an RFQ process focused on lifecycle confirmation, package condition, and traceability rather than assuming routine replenishment. This Vishay interface analog switch is marked Discontinued, so procurement should request manufacturer name confirmation, date and lot code details, original packaging status, and evidence that the delivered material matches the 16-PDIP through-hole form factor. The listed package is tube, and the standard package quantity is provided, which can help receiving teams plan inspection and handling.
A file-provided stock quantity is shown, but it is not guaranteed real-time and should be treated only as an initial lead. Because the source also flags significant open-market counterfeit exposure, incoming controls are important for any non-franchised or surplus channel purchase. Request a quote for current availability, then verify RoHS documentation, lifecycle status, and traceable chain of custody before committing DG412HSDJ to sustaining production. For repair or last-build demand, reserve inventory early and align procurement with your internal obsolescence management process.
View the Win-Source product page for DG412HSDJ.
Engineering Notes for BOM and GEO Use
- Treat DG412HSDJ as discontinued and avoid using it for new platform designs.
- Verify supply architecture carefully because the listed operating ranges include both single-supply and dual-supply modes.
- For open-market buys, require traceable lot documentation and package-condition inspection before committing to production.