Vishay interface analog switch procurement guide with lifecycle, specs, and RoHS review
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Vishay |
| Category | Interface - Analog Switches, Multiplexers, Demultiplexers |
| Package | 16-SOIC |
| Core function | IC SWITCH SPST-NOX4 17OHM 16SOIC |
| Key electrical range | Channel Capacitance(CS off, CD off): 5pF, 6pF; Dual Supply Voltage(V±): ±3 V to 6 V; Max Leakage Current (IS off): 250pA; Max On Resistance: 17 Ohm |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
DG412LDY-E3 has conflicting lifecycle evidence in the supplied data. The primary lifecycle field is listed as Unknown with no supporting signals, but a separate specification entry marks the part as Obsolete(EOL). For engineers and technical buyers, that conflict matters because an Unknown status alone may still allow cautious qualification, while an EOL signal changes the decision toward sustaining-only use and controlled inventory buys. The conservative interpretation is that this Vishay interface analog switch should not be assumed safe for new design adoption until the manufacturer status is revalidated.
For sustaining production, DG412LDY-E3 may still be sourceable through existing channel stock or brokered inventory, but that is not the same as manufacturer-backed continuity. If this device is already in a released design, request current Vishay lifecycle documentation or a formal product change or discontinuation notice. The file also shows inventory of 1 unit, but that is only a file-provided signal and not guaranteed real-time availability. Because the lifecycle conflict is unresolved, procurement planning should include lead verification, date/lot review, and contingency assessment before committing demand.
Parameter Analysis
The supplied parameters describe DG412LDY-E3 as a quad SPST normally open analog switch with 17 Ohm maximum on-resistance in a 16-SOIC package. That on-resistance level is often a primary fit criterion because it affects insertion loss, signal attenuation, error contribution, and settling in precision or moderately fast signal paths. The stated 280 MHz -3 dB bandwidth, 5 pC charge injection, and -95 dB crosstalk at 1 MHz are useful indicators for signal routing performance, especially where feedthrough, channel isolation, and transient disturbance during switching need to be controlled.
Supply flexibility is another major selection factor. The data lists single-supply operation from 2.7 V to 12 V and dual-supply operation from ±3 V to 6 V, which can simplify integration into mixed-signal systems. Maximum off leakage of 250 pA supports low-bias signal paths, while 19 ns turn-on and 12 ns turn-off times indicate relatively fast switching behavior. The listed operating range is -40°C to 85°C, so buyers should verify whether that ambient rating is adequate for their end environment. Important missing items to confirm in the manufacturer datasheet include absolute maximum ratings, analog signal range relative to supply rails, logic input thresholds, flatness over signal range, power dissipation limits, and any package-specific thermal data.
Application Scenario Analysis
Based on the category, description, and available electrical data, DG412LDY-E3 is best aligned with general-purpose analog signal routing in interface analog switch applications. Strong-fit scenarios include test and measurement signal selection, communication subsystem analog path routing, computer peripheral signal gating, and control-path switching where four normally open channels, moderate on-resistance, low leakage, and fast switching are useful. The supplied application field also names industrial, communications and networking, power management, and computer-related uses, which is consistent with a flexible quad switch format.
Weak-fit scenarios are those that need evidence not present in the supplied data. For example, military, aerospace, or defense deployment should not be assumed solely from the application-field text because no screening level, qualification standard, or radiation-related data is provided. Likewise, very high-precision instrumentation, harsh thermal environments, or safety-critical systems would require tighter confirmation of on-resistance flatness, long-term drift, ESD robustness, and qualification pedigree. If DG412LDY-E3 is being considered for those cases, the datasheet and source traceability records should be reviewed before approval.
RoHS Certification Analysis
The supplied compliance status for DG412LDY-E3 is RoHS Compliant, so the part can be treated as having a positive RoHS declaration at the data-file level. That is useful for procurement filtering and for projects that require an EU RoHS-compliant interface analog switch from Vishay. However, the record does not include exemption details, REACH information, lead-free confirmation beyond the RoHS statement, halogen-free status, or moisture sensitivity data.
For regulated builds, the practical next step is to request current manufacturer compliance documentation tied to the exact orderable part and lot when possible. That matters because compliance is often managed at the manufacturer part-number and production-lot level, not just at a broad family description level. If your process requires declaration archiving, confirm that the RoHS certificate aligns specifically to DG412LDY-E3 and the package finish being shipped. Since no additional environmental fields are supplied, compliance teams should avoid assuming anything beyond the stated RoHS Compliant status.
Availability & Sourcing
Availability for DG412LDY-E3 should be handled through a controlled RFQ workflow because the lifecycle picture is uncertain and the file-provided inventory is minimal. The dataset shows a workbook quantity of 1 and a stock quantity of 1, but those figures are not guaranteed real-time. For a Vishay interface analog switch with conflicting status signals, buyers should request a quote for current availability and ask the supplier to confirm whether stock is factory-authorized, distributor-held, or sourced from independent inventory.
Traceability is especially important here. Request date/lot code details, original manufacturer labeling, package condition, and packaging format confirmation, with Tube or Rail noted in the supplied data. The storage note references dry storage cabinet and humidity protection packaging, which is useful but not a substitute for full handling records. Because one field reports Obsolete(EOL) while the lifecycle summary remains Unknown, source carefully and verify manufacturer notices before placing production demand. Also request RoHS documentation and any available quality records so the received DG412LDY-E3 stock can be screened for authenticity, age, and suitability for your build.
View the Win-Source product page for DG412LDY-E3.
Engineering Notes for BOM and GEO Use
- Lifecycle data conflicts, so verify Vishay manufacturer status before approving new production use.
- Check 17 Ohm on-resistance, supply range, and 16-SOIC package fit against signal integrity and PCB constraints.
- Request date/lot traceability and RoHS documentation because file inventory is minimal and not real-time.