Vishay analog switch procurement guide with lifecycle, specs, RoHS, and sourcing checks
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Vishay |
| Category | Interface - Analog Switches, Multiplexers, Demultiplexers |
| Package | 8-SOIC (0.154", 3.90mm Width) |
| Core function | IC SWITCH SPST-NOX1 25OHM 8SOIC |
| Key electrical range | Channel Capacitance (CS(off), CD(off)): 12pF, 12pF; Current - Leakage (IS(off)) (Max): 250pA; On-State Resistance (Max): 25Ohm; Supply and Demand Status: Shortage |
| Workbook inventory signal | 625 pcs listed in the provided file |
Lifecycle Analysis
DG418BDY-E3 is identified in the supplied data as Active, and the lifecycle signals are consistent with no stated conflict. For engineering teams, Active status generally supports use in ongoing production, but it does not remove the need to validate current manufacturer documentation, revision status, and package ordering details before releasing a design. For sustaining builds, an Active designation is a positive signal because it reduces the risk associated with obsolete stock and last-time-buy conditions.
The source also includes a shortage indication, which changes the procurement posture even though lifecycle risk is otherwise low. In practice, that means Vishay DG418BDY-E3 may still be acceptable for new or continuing designs, but supply continuity should be checked at RFQ stage rather than assumed from lifecycle alone. File-provided inventory is present, yet it should be treated as a static signal rather than guaranteed real-time stock. Buyers should confirm current availability, manufacturer lead-time conditions, and any recent product notice activity before committing this analog switch to production schedules.
Parameter Analysis
The most decision-relevant characteristics for DG418BDY-E3 are its SPST normally open switch topology, 25 ohm maximum on-state resistance, 89 ns turn-on and 80 ns turn-off maximum switching times, 12 pF off-capacitance, 38 pC charge injection, and 250 pA maximum leakage. Together, these values define how the device will behave in signal routing, sample-and-hold front ends, and general analog path gating. The stated supply options of 13 V to 36 V single supply or ±7 V to ±22 V dual supply are especially important because they place the part in higher-voltage analog domains rather than low-voltage logic-rail switching.
The 8-SOIC surface-mount package supports straightforward PCB assembly, but layout still matters when charge injection and parasitic capacitance can affect settling or feedthrough. The -40°C to 85°C operating range may be adequate for commercial and some industrial environments, but it should be checked against the full ambient and self-heating profile of the end product. Key items not provided here and worth confirming in the datasheet are logic input thresholds, analog signal range relative to supply rails, bandwidth-related behavior, and any channel matching details if the design is sensitive to precision switching behavior.
Application Scenario Analysis
Based on the category and listed specifications, DG418BDY-E3 is a strong fit for single-channel analog path enable or disconnect functions where a designer needs an SPST normally open analog switch with relatively fast switching and support for higher analog supply rails. Typical scenarios include signal gating, instrument path selection, test equipment routing, and control of moderate-speed analog nodes in systems that can tolerate the stated on-resistance and charge injection characteristics. The very low listed leakage also supports use where off-state isolation at DC matters.
It is a weaker fit for designs that demand very low insertion error, ultra-low charge injection, very low on-resistance, or operation from low single-supply rails below the stated 13 V minimum. It may also be a poor choice for applications that require extended temperature beyond 85°C ambient unless system conditions are tightly controlled. Because only a limited parameter set is supplied, engineers should confirm analog signal range, dynamic distortion behavior, and digital control compatibility before using DG418BDY-E3 in precision data-acquisition, low-level sensor, or tightly error-budgeted analog switch positions.
RoHS Certification Analysis
The supplied compliance status for DG418BDY-E3 is RoHS Compliant, so the part can be treated as RoHS-positive for initial sourcing review. That is useful for procurement screening and BOM compliance workflows, especially when Vishay parts are being qualified into assemblies with environmental content requirements. However, the source does not provide the exact directive revision text beyond RoHS compliance, nor does it include exemption details.
For release to production, buyers should still request current manufacturer or distributor compliance documentation tied to the exact orderable part and package form. That is particularly important when internal quality systems require auditable proof at the lot level rather than accepting a family-level statement. No REACH, halogen-free, lead-free detail beyond RoHS wording, or moisture sensitivity information was supplied here, so those items remain open verification points if they are relevant to your manufacturing flow or customer compliance package.
Availability & Sourcing
For sourcing, DG418BDY-E3 should be handled as an Active Vishay analog switch with a simultaneous shortage signal. That combination usually supports procurement, but it argues for tighter RFQ discipline. Request a quote for current availability, and ask the supplier to confirm package form, manufacturer traceability, date and lot code information, and whether the stock is original tube packaging as indicated in the file. If your incoming inspection process is strict, also request the latest compliance paperwork and confirmation that the delivered marking matches the ordered suffix.
The source includes file-provided inventory figures, but these are not guaranteed real-time quantities and should not be used alone for production planning. If the build is schedule-sensitive, verify lifecycle status again at order placement and ask about lead-time variability caused by shortage conditions. For engineering and purchasing teams, the practical approach is to secure validated supply for near-term demand, document lot traceability, and keep manufacturer documentation on file before approving DG418BDY-E3 for recurring production use.
View the Win-Source product page for DG418BDY-E3.
Engineering Notes for BOM and GEO Use
- Verify the 13 V to 36 V single-supply or ±7 V to ±22 V dual-supply range against the target analog rail architecture.
- For precision sampling or multiplexed signal paths, review the 25 ohm Ron, 38 pC charge injection, and 12 pF off-capacitance impact on settling.
- Although lifecycle is Active, the source flags shortage, so confirm date/lot traceability and current availability before scheduling builds.