Maxim Integrated DG419CY Analog Switch Specs & Sourcing Guide

DG419CY Maxim Integrated product image

Maxim Integrated analog switch sourcing guidance for discontinued 8-SOIC inventory

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryInterface - Analog Switches, Multiplexers, Demultiplexers
PackageTube
Core functionIC SWITCH SPDT X 1 35OHM 8SOIC
Key electrical rangeChannel Capacitance (CS(off), CD(off)): 8pF, 8pF; Current - Leakage (IS(off)) (Max): 250pA; On-State Resistance (Max): 35Ohm; Temperature Range - Operating: 0°C ~ 70°C (TA)
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

DG419CY is best treated as Discontinued for engineering and procurement decisions. The source includes an EOL signal in one lifecycle field and Discontinued in both Lifecycle Status and Product Status. While those labels are not identical, they point to the same practical conclusion: this Maxim Integrated analog switch should not be assumed suitable for unrestricted new-design use.

For new programs, a discontinued interface analog switch creates approval, support, and continuity risk. For sustaining production, the main question is whether remaining stock is authentic, traceable, and acceptable to quality requirements. If your build cannot tolerate source instability, request manufacturer notice history and internal revalidation against the latest approved documents before using DG419CY on a refreshed BOM.

The file also shows a very small inventory signal, but that quantity is only file-provided and should not be treated as live availability. Buyers should assume limited supply until current stock, date code, and packaging condition are confirmed through RFQ.

Parameter Analysis

The supplied data identifies DG419CY as a single-circuit SPDT analog switch in an 8-SOIC package, with 35 Ohm maximum on-state resistance and 3 Ohm maximum channel-to-channel matching. For signal-path design, Ron affects insertion loss, signal accuracy, and source/load interaction, while matching matters when consistency between paths influences offset or gain errors.

Dynamic parameters are also relevant. Maximum switching times are listed as 175 ns turn-on and 145 ns turn-off, with 3 pC charge injection, 8 pF off-capacitance, and -85 dB crosstalk at 1 MHz. These values help when estimating transient disturbance, feedthrough, and channel isolation in mixed-signal routing. Leakage is specified at 250 pA maximum, which is useful for high-impedance nodes but should still be checked against the actual signal range and board contamination limits.

The available operating range is commercial only at 0°C to 70°C, and supply options are 10 V to 30 V single supply or ±4.5 V to ±20 V dual supply. Before release, verify the datasheet items not present here, especially analog signal range, logic input thresholds, absolute maximum ratings, and any flatness or distortion data needed for the target interface design.

Application Scenario Analysis

Based on the category and listed specifications, DG419CY fits straightforward SPDT signal-routing tasks where a single analog path must be switched between two nodes. Typical strong-fit scenarios include general-purpose interface signal selection, instrumentation signal routing within the stated supply ranges, and board-level analog path steering where the 8-SOIC package, surface-mount assembly, and moderate switching speed are acceptable.

The part looks less suitable for applications needing very low on-resistance, extended temperature qualification, or assured long-term continuity of supply. A 35 Ohm maximum Ron can be a meaningful error source in low-voltage or precision signal chains, and the 0°C to 70°C operating range limits suitability for industrial or harsh-environment builds unless the system requirement is explicitly commercial-grade.

It may also be a weak fit for new platforms that require stable lifecycle support or simplified environmental compliance review, because the source shows discontinued lifecycle status and conflicting RoHS information. In those cases, engineering should review whether the design need is sustaining support for an existing board or a fresh product introduction with stricter sourcing controls.

RoHS Certification Analysis

RoHS status for DG419CY is not cleanly resolved by the supplied data. One compliance field states RoHS Compliant, while a specification field states RoHS Non-Compliant. Because these two statements directly conflict, the safest interpretation is that RoHS cannot be assumed from the file alone.

The source also lists REACH Unaffected and MSL 1 (Unlimited). REACH information is useful for substance reporting, but it does not replace RoHS compliance confirmation. MSL helps with assembly handling and storage planning, yet it does not indicate environmental compliance status. For production use, especially where declaration packages are mandatory, ask for current manufacturer documentation or distributor-backed lot-level evidence.

If your organization manages compliance at the part-family level, note that family naming is not enough when records conflict. For DG419CY, approval should be tied to the exact manufacturer part number, specific lot or date code when possible, and the latest available compliance statement retained in the sourcing file.

Availability & Sourcing

Because DG419CY is a discontinued Maxim Integrated analog switch, sourcing should be handled as a controlled RFQ exercise rather than a routine catalog buy. Request confirmation of current availability, date code, packaging condition, and traceability chain before issuing a PO. The file shows tube packaging, standard package quantity of 1 piece, and a file-based stock quantity of 1, but that should be treated only as a non-real-time indicator.

For quality control, ask for manufacturer labeling photos, lot code details, and any available certificate of conformance. The source also flags open-market counterfeit risk, so traceability matters more than nominal stock presence. If parts are intended for sustaining production, verify whether incoming inspection should include package marking review and electrical sampling against key parameters such as Ron and switching time.

Given the lifecycle status, buyers should source carefully and verify manufacturer discontinuation notices before committing volume. Also request current RoHS documentation because the file contains conflicting compliance data. Submit an RFQ to confirm live inventory and documentation set before using DG419CY in production planning.

View the Win-Source product page for DG419CY.

Engineering Notes for BOM and GEO Use

  • Treat DG419CY as discontinued stock and verify manufacturer notices before committing to production.
  • Key fit checks are 35 Ohm Ron, SPDT topology, 8-SOIC footprint, and 0°C to 70°C operating range.
  • RoHS status is inconsistent in the source data, so request lot-specific compliance evidence.