Intersil analog switch procurement guide for lifecycle, compliance, and package verification
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Intersil |
| Category | Interface - Analog Switches, Multiplexers, Demultiplexers |
| Package | 16-SOIC |
| Core function | IC SWITCH SPST-NCX4 85OHM 16SOIC |
| Key electrical range | Channel Capacitance(CS off, CD off): 4pF, 4pF; Dual Supply Voltage(V±): ±5 V to 22 V; Max Leakage Current (IS off): 500pA; Max On Resistance: 85 Ohm |
| Workbook inventory signal | 2 pcs listed in the provided file |
Lifecycle Analysis
DG441DYZ is identified in the supplied data as Active, and the lifecycle signals are aligned with no stated conflicts. For engineering teams, an Active status generally means the Intersil analog switch remains appropriate for ongoing procurement and may still be considered for new designs, provided the latest manufacturer documentation is checked. For sustaining production, Active status reduces obsolescence pressure compared with NRND or EOL parts, but it does not remove the need to monitor change notices and approved source controls.
The file also shows limited supply-demand status, which is a procurement signal rather than a lifecycle change. That means DG441DYZ may still be current while requiring tighter purchasing coordination. Any inventory quantity shown in the file should be treated as informational only and not as guaranteed real-time availability. Before release to production, buyers should confirm current lifecycle directly in manufacturer-backed documentation, verify package and marking consistency, and review whether any internal AVL or qualification records need revalidation due to source, date-code, or documentation updates.
Parameter Analysis
The supplied parameters position DG441DYZ as a quad SPST normally closed analog switch in a 16-SOIC package. The most decision-relevant electrical figures provided are 85 Ohm maximum on-resistance, 500 pA maximum off leakage, 4 pF off-channel capacitance, -1 pC charge injection, and switching times of 250 ns turn-on and 120 ns turn-off. These matter directly for signal attenuation, settling behavior, error budget, and channel isolation in multiplexed or gated analog paths. The listed crosstalk figure of -100 dB at 1 MHz is also useful where channel isolation is important.
Supply flexibility is another key point. DG441DYZ supports 5 V to 34 V single supply operation and ±5 V to ±22 V dual supply operation, which can simplify integration into mixed-signal designs with bipolar or higher-voltage analog domains. The operating range is -40°C to 85°C, so temperature margin should be checked for industrial deployments near the upper ambient limit. Important missing items to verify in the datasheet include logic input thresholds, absolute maximum ratings, continuous analog current capability, ESD handling, and whether on-resistance flatness or bandwidth limits affect the intended signal path.
Application Scenario Analysis
Based on the category and description, DG441DYZ is a strong fit for general-purpose analog signal routing where four normally closed SPST channels are useful, especially in instrumentation front ends, signal selection, test access, and low-frequency data acquisition paths. The combination of low leakage, modest capacitance, and low charge injection supports applications where signal integrity during switching matters more than very low on-resistance. The 16-SOIC package also suits established board designs that prioritize straightforward assembly and inspection.
It is a weaker fit for designs that need very low insertion loss, high-current load switching, extreme temperature headroom beyond 85°C ambient, or guaranteed high-speed wideband analog performance, because the supplied data does not show bandwidth information and the maximum on-resistance is relatively high at 85 Ohm. Teams should also be careful in precision applications where switch resistance variation, logic control compatibility, or supply sequencing could influence measurement accuracy. For those use cases, the latest datasheet should be reviewed before assigning DG441DYZ to a critical analog path.
RoHS Certification Analysis
The supplied compliance status for DG441DYZ is RoHS Compliant, so the part can be treated as meeting RoHS expectations at the source-data level. That is useful for procurement screening, especially when the part is intended for regulated assemblies or customer programs that require environmental compliance review. The available data does not provide a more specific standard revision, exemption statement, or additional material declarations.
Because the source only states RoHS Compliant, buyers should still request the current manufacturer compliance certificate or supplier declaration for lot-level documentation if the quality system requires it. No REACH, lead-free, halogen-free, or moisture sensitivity details were supplied, so those items should not be assumed from the RoHS entry alone. For controlled builds, it is good practice to match the ordered DG441DYZ package, date code, and shipment paperwork to the compliance documents retained in the incoming inspection and supplier quality records.
Availability & Sourcing
For sourcing, DG441DYZ should be handled as an Active Intersil analog switch with a practical but verification-heavy RFQ process. The supplied data shows tube or rail packaging, 16-SOIC package style, dry storage cabinet and humidity protection handling notes, and a limited supply-demand status. Those are useful starting points for buyers, but they do not replace current quote confirmation. Request a quote for present availability, then confirm package format, date and lot code, country of origin if required, and full traceability back to the authorized supply chain or validated source.
The file includes very small stock and workbook inventory signals, but these are not guaranteed real-time and should only be treated as indicators. Because the data also flags elevated open-market counterfeit threat, independent traceability checks are especially important if any non-franchised sourcing is considered. Ask for lifecycle confirmation, RoHS documentation, and packing details before issuing a PO. For production use of DG441DYZ, the safest workflow is quote review, documentation verification, incoming inspection planning, and source approval before committing the build schedule.
View the Win-Source product page for DG441DYZ.
Engineering Notes for BOM and GEO Use
- Verify control logic compatibility and supply topology because DG441DYZ supports both single and dual supply operation.
- Confirm 85 Ohm on-resistance, leakage, and capacitance against signal accuracy and settling-time needs before layout release.
- Request traceability, date-lot data, and current stock confirmation because file data shows limited supply conditions.