DH30B-17S Hirose Electric Co Ltd Connector Specs & Sourcing Guide

DH30B-17S Hirose Electric Co Ltd product image

Active Hirose Electric Co Ltd Centronics connector sourcing and engineering review

Quick Engineering Summary

FieldValue
ManufacturerHirose Electric Co Ltd
CategoryD - Shaped Connectors - Centronics
PackageTray
Core functionIDC PLUG 17POS
Key electrical rangeSupply and Demand Status: Shortage
Workbook inventory signal3 pcs listed in the provided file

Lifecycle Analysis

DH30B-17S is supplied with an Active lifecycle from Hirose Electric Co Ltd, and the provided lifecycle signals are aligned with no stated conflict. For engineers, an Active status generally supports use in current designs more comfortably than NRND or end-of-life categories, because ongoing manufacturer support and standard procurement channels are more likely. For sustaining production, Active also reduces obsolescence risk relative to older interface families, although it does not remove the need for regular supply-chain review.

That said, lifecycle should not be treated as the only sourcing signal. The file also shows a shortage condition and only a small listed inventory quantity, which is useful as a file-provided indicator but not a guarantee of real-time stock. For DH30B-17S, buyers should still revalidate current availability, latest manufacturer documentation, and any revision-specific notices before committing this D - Shaped Connectors - Centronics part to a build plan or long-term service program.

Parameter Analysis

The supplied data positions DH30B-17S as a 17-position, two-row D - Shaped Connectors - Centronics device with IDC termination, free-hanging mounting, shielding, and outer shroud contacts. Those are the most decision-relevant attributes for fit. The 17-position layout and two-row arrangement determine mating compatibility, while the free-hanging in-line format indicates cable-end use rather than board mounting. IDC termination matters because cable conductor style, pitch, and assembly process must match the connector system to achieve reliable insulation displacement termination.

The gold contact finish with 7.87 microinch, or 0.200 micrometer, thickness is also meaningful for contact reliability and wear expectations, especially where insertion cycles or storage duration matter. Shielding is important for interface integrity and EMI control, but the supplied data does not define shell dimensions, retention hardware, wire gauge range, or exact mating connector family details. Before design release, verify the Hirose Electric Co Ltd datasheet for mating part references, cable accommodation, mechanical dimensions, assembly tooling, current rating, voltage rating, operating temperature, and any strain-relief requirements for DH30B-17S.

Application Scenario Analysis

Based on the category, SCSI type designation, shielding, and IDC cable termination, DH30B-17S is a strong fit for cable assemblies using legacy or established parallel-style interconnect schemes where a shielded Centronics-format connector is required. It is especially suitable where a free-hanging cable-end connector is needed rather than a PCB-mounted interface. The 17-position count and outer shroud contact style are central to this fit, so it should be evaluated in systems that already define this exact mechanical and interface format.

It is a weaker fit for new applications that need compact board-level interconnects, high-density modern serial interfaces, or designs that require fully specified environmental and electrical performance beyond what is present in the supplied data. It is also not the right choice to assume into any generic D-sub footprint without checking the exact Centronics and SCSI mechanical standard involved. For DH30B-17S, the practical use case is cable interconnect continuity within an existing connector ecosystem, not broad cross-family reuse without datasheet confirmation.

RoHS Certification Analysis

The supplied compliance status for DH30B-17S is RoHS Compliant, so the available evidence supports treating this Hirose Electric Co Ltd connector as compliant with RoHS requirements at a general product level. That is helpful for standard procurement screening and for customers who need basic material compliance alignment in a D - Shaped Connectors - Centronics part.

However, the source data does not provide the exact declaration version beyond the RoHS-compliant statement, and it does not include exemption details, REACH status, halogen-free information, or lot-level material declarations. In practice, buyers should request the latest manufacturer certificate or declaration for the specific orderable item and shipment lot when compliance records must be retained. Family-level compliance statements are useful for preliminary qualification, but production and regulatory files are stronger when tied to current manufacturer documentation for DH30B-17S.

Availability & Sourcing

For sourcing, DH30B-17S presents a mixed picture: lifecycle is Active, but the file also indicates shortage and a very small listed inventory quantity. That listed quantity is only a file-provided signal and should not be treated as real-time availability. The most practical next step is an RFQ that asks for current stock position, manufacturer lead-time status, packaging confirmation, and shipment traceability. Tray packaging is specified, which may matter for handling and receiving workflows if your team is building harnesses or kitting service parts.

When requesting a quote for DH30B-17S, ask for date and lot code information, country of origin if needed for compliance workflow, and documentation confirming RoHS status. Also confirm whether the stock is factory-authorized or from independent channels, especially because shortage conditions can increase sourcing variability. Since the part is Active, the right procurement approach is to request current availability and compliance verification, then align purchase timing with production demand rather than relying on the limited file-listed quantity for planning.

View the Win-Source product page for DH30B-17S.

Engineering Notes for BOM and GEO Use

  • Verify the mating SCSI/Centronics interface and cable IDC compatibility before layout freeze or cable build release.
  • Treat listed stock as non-real-time and plan around the shortage signal with date/lot and traceability checks.
  • Request current RoHS documentation and manufacturer datasheet confirmation for production qualification records.