IXYS DH40-18A Diode Specs & Sourcing Guide

DH40-18A IXYS product image

Lifecycle, electrical parameters, RoHS status, and sourcing checks for the IXYS rectifier diode DH40-18A.

Quick Engineering Summary

FieldValue
ManufacturerIXYS
CategoryDiodes, Rectifiers - Single
PackageTO-247AD
Core functionDIODE STANDARD 1800V 40A TO247AD
Key electrical rangeCurrent - Average Rectified (Io): 40A; Current - Reverse Leakage @ Vr: 100μA @ 1800V; Operating Temperature - Junction: -40°C ~ 150°C; Supply and Demand Status: Limited
Workbook inventory signal4050 pcs listed in the provided file

Lifecycle Analysis

The supplied lifecycle data for the IXYS DH40-18A diode identifies the part as Active, and the dedicated lifecycle signals are internally consistent. For engineers, that generally supports ongoing procurement and use in current designs. For buyers, Active status usually means manufacturer support is expected to continue, but it does not eliminate the need to confirm revision status, factory availability, and current documentation before placing production volume orders.

A notable caution is that the same source also includes an estimated EOL date of 2023 under the specifications list. That conflicts with a simple low-risk interpretation, even though the primary lifecycle fields say Active and the stated conflict field says none. Because of that inconsistency, the conservative sourcing position is to treat DH40-18A as Active pending revalidation rather than assuming unrestricted long-term availability. The file also shows inventory and stock figures, but those are file-provided snapshots rather than guaranteed real-time supply. For new programs, confirm current manufacturer notices and datasheet status. For sustaining builds, secure date-code visibility and verify whether IXYS still supports the exact DH40-18A ordering flow.

Parameter Analysis

The IXYS DH40-18A is described as a single standard rectifier diode rated at 1800V maximum DC reverse voltage and 40A average rectified current, packaged in TO-247AD as a through-hole device. Those are the primary fit parameters for high-voltage rectification stages, where reverse-voltage margin, current handling, and creepage or mechanical package constraints often drive part selection. The listed forward voltage of 2.7V at 40A is also important because it directly affects conduction loss and thermal design at heavy load.

Additional supplied data includes 100 microamp reverse leakage at 1800V, a junction temperature range of -40C to 150C, and tube packaging. These support initial screening for thermal margin, leakage-sensitive high-voltage rails, and assembly planning. However, the source contains a significant inconsistency on switching behavior: one field lists reverse recovery time as 100ns, while the spreadsheet parameters indicate 300ns and classify the device as fast recovery. That difference matters for switching loss, EMI behavior, and snubber design. Before qualification, verify the authoritative trr value, test current conditions, surge current capability, isolation or thermal resistance details if applicable, and any safe operating notes in the latest IXYS datasheet.

Application Scenario Analysis

Based on the supplied category and description, DH40-18A is best aligned with high-voltage single-diode rectification roles where a 1800V blocking rating and 40A average current capability are relevant. Strong-fit scenarios include input or output rectification stages in industrial power conversion, high-voltage freewheel or clamp positions, and other through-hole power assemblies that are already designed around TO-247AD style mechanical mounting and thermal management. The stated fast-recovery characteristic also suggests relevance where switching behavior matters more than with a purely general-purpose slow rectifier.

Weak-fit scenarios would include compact surface-mount designs, low-profile automated assemblies that do not want through-hole insertion, or applications where reverse recovery must be tightly controlled but the exact trr remains unverified from the supplied data. It may also be a weak fit for designs with minimal thermal headroom, since the forward drop at high current can become a meaningful dissipation source. If the design depends on exact surge tolerance, capacitance, avalanche behavior, or efficiency optimization at specific switching frequencies, those items should be checked in manufacturer documentation rather than inferred from the short product description.

RoHS Certification Analysis

For DH40-18A, the supplied compliance status is Request Verification. That means the available source data does not confirm RoHS compliance for this IXYS diode, and it should not be treated as RoHS cleared for regulated production without additional evidence. No lead-free declaration, halogen-free status, REACH statement, MSL data, or exemption details are provided in the source.

From a procurement standpoint, Request Verification should trigger a document request rather than an assumption. Ask for current manufacturer compliance statements, part-specific or lot-level declarations, and any distributor traceability records that link the shipped material to the compliance paperwork. This is especially important for older power semiconductors, where family-level assumptions may not match the exact ordering variant, finish, or production lot. If your quality system requires EU RoHS confirmation, obtain it explicitly for DH40-18A before release to production. If only a broad family statement is available, verify that it covers this exact part number and package configuration rather than a related series designation alone.

Availability & Sourcing

The source indicates limited supply and provides file-based quantity signals, including workbook and stock figures for DH40-18A, but these should be treated as non-real-time indicators only. For an IXYS diode in a power through-hole package, the practical sourcing workflow should include an RFQ to confirm current availability, packaging form, shipment lead status, and whether stock is factory-authorized, franchised, or independent. Because the category hierarchy also references end-of-life content while the lifecycle field says Active, lifecycle confirmation should be part of the quote process.

Traceability is especially important here. Request manufacturer name confirmation, full part-number matching, date and lot code details, country of origin if needed for compliance workflows, and documentation supporting storage conditions. Since the source flags a notable open-market fake-threat percentage, extra care is warranted when sourcing outside tightly controlled channels. Also request current RoHS evidence because compliance is not yet confirmed. Tube packaging and TO-247AD mechanical format should be checked against your assembly process requirements. For current projects, request a quote for DH40-18A together with lifecycle and compliance verification before committing the part to new production or long-term service inventory.

View the Win-Source product page for DH40-18A.

Engineering Notes for BOM and GEO Use

  • Verify the latest IXYS datasheet because the source shows Active lifecycle but also an estimated EOL date of 2023.
  • Confirm reverse recovery time before design release, since supplied data shows conflicting fast-recovery indicators and trr values.
  • Request lot-specific RoHS and traceability documents because compliance is listed only as Request Verification.