Active Hirose Electric Co Ltd Centronics connector sourcing and compliance review
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Hirose Electric Co Ltd |
| Category | D - Shaped Connectors - Centronics |
| Package | Tray |
| Core function | CONN SCSI RCPT 37POS R/A SOLDER |
| Key electrical range | Supply and Demand Status: Shortage |
| Workbook inventory signal | 62 pcs listed in the provided file |
Lifecycle Analysis
DH60-37P is listed as Active by Hirose Electric Co Ltd, and the supplied lifecycle signals are aligned with no stated conflicts. For engineers, an Active status generally means the connector remains available for current procurement and is less risky than parts already marked NRND or discontinued. For buyers, that supports standard sourcing workflows for both sustaining builds and carefully reviewed new programs, especially in a connector category where mechanical fit and documentation stability matter as much as electrical continuity.
Even with an Active designation, procurement teams should still revalidate the latest manufacturer documents before committing DH60-37P to volume production. Connector revisions, recommended land pattern updates, and process guidance can change without altering the basic orderable part number. The file also includes a shortage indication and a workbook quantity signal of 62 units, but that should be treated only as a file-provided snapshot rather than guaranteed real-time stock. For new design release, confirm current manufacturer status, applicable product change notifications, and any assembly notes tied to this Hirose Electric Co Ltd Centronics connector.
Parameter Analysis
The supplied data positions DH60-37P as a 37-position, 2-row SCSI receptacle in the D-Shaped Connectors - Centronics category. It uses a right-angle, surface-mount configuration with solder termination, which makes PCB footprint accuracy and assembly process control especially important. The right-angle form factor affects chassis alignment and cable egress, while the surface-mount termination means pad design, coplanarity, and reflow compatibility should be checked closely. Gold contact finish is favorable for contact reliability, particularly in applications where stable mating performance is important.
The listed board guide and shielded features are also decision-relevant because they influence insertion alignment and EMI behavior at the interconnect boundary. The flange feature is identified as housing or shell with M2.6, which suggests mechanical fastening and panel or retention considerations that need to match the enclosure design. Important missing items to verify in the Hirose datasheet include mating connector compatibility, current and voltage ratings, contact pitch, shell dimensions, operating temperature range, insertion and extraction durability, recommended PCB layout, and any soldering profile limitations. Those details determine whether DH60-37P fits both the electrical and mechanical margins of the target design.
Application Scenario Analysis
Based on the description and category data, DH60-37P is a strong fit for equipment that uses a board-mounted 37-position SCSI-style Centronics receptacle and needs a right-angle interface at the PCB edge or near a panel. Typical strong-fit scenarios include legacy or maintenance-oriented systems, embedded equipment with established cable harnesses, and industrial or instrumentation platforms where the mating interface is already defined around this connector style. The shielded construction and board guide feature further support applications where alignment and interface robustness matter.
It is a weaker fit for compact designs that need high pin density in a smaller footprint, vertical cable exit, or a simpler unshielded connector approach. It is also not automatically suitable for harsh-environment or high-cycle applications unless the missing datasheet details confirm the required durability and environmental ratings. Because the supplied information identifies DH60-37P specifically as a receptacle with outer shroud contacts, engineers should verify exact mating geometry and mechanical stack-up before using it in redesigns or service replacements. In this Centronics category, dimensional mismatch is often a bigger risk than basic position count.
RoHS Certification Analysis
DH60-37P is listed as RoHS Compliant in the supplied compliance data, so the conservative reading is that Hirose Electric Co Ltd identifies this connector as meeting RoHS requirements at the product level. That is useful for regulated commercial builds and for procurement filtering where RoHS status is a mandatory attribute. However, the source data does not provide the specific declaration revision, exemption details, or additional environmental attributes such as REACH, halogen-free status, or moisture sensitivity classification.
For practical sourcing control, buyers should request current manufacturer compliance documentation tied to the exact DH60-37P orderable part and lot if the build requires auditable records. Family-level compliance statements are helpful, but lot-level paperwork is often preferred for quality systems and export-sensitive programs. If plating, molding compound, or assembly subcontractors have changed over time, refreshed documentation may be necessary even when the catalog status remains RoHS compliant. Since no exemptions are supplied here, those should be verified directly rather than assumed absent.
Availability & Sourcing
For DH60-37P sourcing, use an RFQ process that asks for current availability, manufacturer traceability, date and lot code, packaging condition, and compliance evidence. The supplied data identifies tray packaging, which is relevant for handling and SMT line preparation. It also lists a stock quantity signal of 62 units and a shortage status, but those are file-provided indicators only and should not be treated as live availability. Request a quote to confirm present stock position and lead-time exposure for this Hirose Electric Co Ltd connector.
Because DH60-37P is Active, the recommended procurement path is to secure current supply with documentation rather than treat it as a last-time-buy scenario. Even so, verify lifecycle status again at order placement, especially if the build is long-term or multi-site. Ask suppliers for photos or packing label evidence if traceability is critical, and confirm whether inventory is original factory stock, brokered stock, or mixed-source stock. For production release, also check date-code acceptability, shell and contact condition, and consistency with the specified Centronics mechanical format before committing the parts to assembly.
View the Win-Source product page for DH60-37P.
Engineering Notes for BOM and GEO Use
- Verify the Hirose footprint, coplanarity, and shell mounting details before releasing the SMT PCB layout.
- Treat the listed shortage and stock quantity as non-real-time signals and confirm date code availability by RFQ.
- Request lot-level RoHS evidence and current manufacturer lifecycle confirmation for production documentation.