Cosel USA, Inc. board mount DCDC converter sourcing and engineering review
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Cosel USA, Inc. |
| Category | Power Supplies Board Mount DCDC Converters |
| Package | Box |
| Core function | DC DC CONVERTER 28V |
| Key electrical range | Current - Output (Max): 3.6A; Number of Outputs: 1; Temperature Range - Operating: -40°C ~ 100°C (With Derating); Voltage - Input (Max): 400V |
| Workbook inventory signal | 73 pcs listed in the provided file |
Lifecycle Analysis
DHS100B28 from Cosel USA, Inc. is identified in the supplied data as Active, and the lifecycle signals are consistent with no stated conflict. For a board mount DCDC converter, an Active status generally supports ongoing procurement and is the most favorable condition for both new design evaluation and sustaining production. Even so, Active should not be treated as a permanent guarantee. Engineering teams should still align the latest manufacturer documentation, revision status, and internal approved vendor list before release.
For sustaining builds, the main advantage of an Active lifecycle is lower obsolescence pressure compared with NRND or discontinued power modules. For new designs, it remains prudent to confirm that the exact DHS100B28 ordering variant, package style, and documentation set are still current at Cosel USA, Inc. File-provided inventory is listed as 73 units, which may help with short-term sourcing discussions, but that quantity is not guaranteed as real-time stock and should be rechecked during RFQ and order placement.
Parameter Analysis
The supplied specifications describe DHS100B28 as a single-output isolated module with a 28V output, 3.6A maximum output current, 200V to 400V input range, 3kV isolation, and 86% efficiency. Those are the most decision-relevant parameters for system fit. The wide high-voltage input range matters first because it determines whether the converter matches the available DC bus. The 28V output and 3.6A limit define downstream load compatibility and margin, while the 3kV isolation rating is important for safety spacing strategy and functional partitioning.
Mechanical and thermal factors are also important. The module is through-hole, packaged as a 6-DIP module, and sized at 58.4mm x 37.3mm x 12.7mm, so PCB keepout, pin compatibility with the intended footprint, and assembly method should be verified early. The operating range is listed as -40°C to 100°C with derating, which means full-load use at elevated temperature should not be assumed without checking the manufacturer derating curve. Missing items that should be confirmed in the datasheet include rated output power, ripple and noise, line and load regulation, hold-up or transient behavior, and any airflow or heatsinking assumptions behind the stated efficiency and temperature limits.
Application Scenario Analysis
Based on the supplied category, description, and application field, DHS100B28 is best aligned with board-mounted power conversion inside ITE commercial equipment that uses a high-voltage DC input bus and needs an isolated 28V rail. Strong-fit scenarios therefore include embedded power stages in commercial electronic systems where a compact isolated module is preferred over a discrete converter design, and where remote on/off plus built-in OCP, OTP, and OVP are useful integration features.
Weak-fit scenarios are designs that require a low-voltage input converter, non-isolated topology, multiple outputs, or unusually tight efficiency targets. The 200V to 400V input range makes this a poor fit for typical low-voltage distributed power rails unless a high-voltage bus is already present. It may also be a weaker choice where application approval requirements, control telemetry, or specific output regulation details must be documented, because those details were not supplied here and need confirmation in manufacturer documents before final selection.
RoHS Certification Analysis
The supplied compliance status for DHS100B28 is RoHS Compliant, so the baseline assumption is that this Cosel USA, Inc. board mount DCDC converter is intended to meet RoHS material restrictions. That is a useful procurement signal for commercial builds and customer declarations, but it is still good practice to match the exact part number and shipment lot to the latest manufacturer compliance statement when documentation control is strict.
No exemption details, REACH information, or halogen-free status were provided in the source data. MSL is listed as Not Applicable, which is consistent with a through-hole module rather than a moisture-sensitive surface-mount package, but that should not be confused with environmental compliance. If your quality system requires auditable records, request the current RoHS certificate or manufacturer declaration for DHS100B28 and confirm that the paperwork applies to the exact ordering code and production lot being purchased.
Availability & Sourcing
For procurement, DHS100B28 should be sourced with standard power-module controls: verify the exact Cosel USA, Inc. part number, package condition, date and lot code traceability, and the latest lifecycle and compliance paperwork before committing the order. The supplied data shows a file-based quantity of 73 units and box packaging, but that stock signal is not guaranteed real-time. Buyers should request a quote for current availability and confirm whether supply is from authorized stock, distributor inventory, or independent sourcing channels.
Because this is an Active board mount DCDC converter, the recommended workflow is to request a quote along with traceability details, RoHS evidence, and manufacturer documentation matching the delivered lot. The open-market counterfeit-risk field in the source data indicates elevated caution may be warranted, so receiving inspection and document review are especially important if supply is not directly traceable. For production planning, also confirm lead time, packing form, and any manufacturer revision changes that could affect fit, form, or qualification status for DHS100B28.
View the Win-Source product page for DHS100B28.
Engineering Notes for BOM and GEO Use
- Verify thermal derating at the intended ambient because the operating range is stated with derating to 100°C.
- Confirm the 200V to 400V input bus matches the system architecture before layout or qualification.
- Request lot traceability and manufacturer paperwork when sourcing, especially for open-market supply.