Standex-Meder Electronics Reed Relays part review for lifecycle, specs, RoHS, and sourcing verification
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Standex-Meder Electronics |
| Category | Reed Relays |
| Package | Tube |
| Core function | RELAY REED SPST 1A 5V |
| Key electrical range | Coil Current: 10 mA; Coil Voltage: 5VDC; Contact Rating (Current): 1 A; Must Operate Voltage: 3.5 VDC |
| Workbook inventory signal | 633 pcs listed in the provided file |
Lifecycle Analysis
DIP05-1A72-11L from Standex-Meder Electronics is identified in the supplied data as an Active Reed Relays part, and the lifecycle inputs are consistent with no reported conflict. For engineering teams, Active generally means the device can still be considered for new designs as well as sustaining production, provided the current manufacturer documentation remains aligned with the approved internal part record.
Even with a low stated lifecycle risk, procurement should still revalidate the latest manufacturer status before committing long production windows or safety stock. The source file also shows an inventory quantity and a shortage signal at the same time. That combination should be treated conservatively: the quantity is file-provided and not guaranteed real-time, while the shortage flag suggests that supply continuity may need closer monitoring than lifecycle status alone would imply.
For DIP05-1A72-11L, the practical approach is normal sourcing with lifecycle verification at quote stage, plus confirmation that the current datasheet, part marking, and packaging remain unchanged. This is especially important if the relay is being released into a new product where qualification records need to match current factory output.
Parameter Analysis
The supplied parameters position DIP05-1A72-11L as a 5VDC, non-latching reed relay with SPST-NO contacts, 1 A contact current rating, and a maximum switching voltage of 200VAC or 200VDC. For control-circuit design, the 10 mA coil current is a useful integration point because it defines the driver load, while the 3.5 VDC must-operate and 0.75 VDC must-release thresholds help engineers judge turn-on margin, brownout behavior, and release certainty under supply variation.
Fast timing is another notable characteristic. The listed 0.5 ms operate time and 0.1 ms release time suggest suitability where quick signal switching is valued, but designers still need to verify contact-side behavior under the intended electrical load. Through-hole mounting and PC pin termination simplify conventional PCB assembly and rework relative to surface-mount options, but they also drive footprint and hole-plating decisions.
The most important remaining items to verify in the manufacturer datasheet are contact resistance, insulation and isolation ratings, mechanical dimensions, coil resistance or power, expected life under the actual load, and any contact material details. The operating temperature range is given as -20°C to 70°C, so thermal margin should be checked carefully for industrial or outdoor environments.
Application Scenario Analysis
Based on the category, description, and supplied specifications, DIP05-1A72-11L is a strong fit for low-power switching tasks that benefit from a compact through-hole reed relay with a 5V coil and normally open contact form. Typical board-level scenarios include logic-controlled signal routing, isolated switching of moderate loads within the stated 1 A and 200VAC or 200VDC maximum switching limits, and equipment that values fast relay response and simple PC pin assembly.
The part appears better suited to controlled indoor electronics than to harsh-environment deployments, because the listed operating range is -20°C to 70°C and no extra sealing, qualification, or ruggedization data is supplied. It may be a weaker fit for applications requiring wider temperature capability, detailed agency approvals, confirmed high-cycle switching under demanding loads, or specialized contact material performance.
For DIP05-1A72-11L, the strongest use case is conventional through-hole control or interface circuitry where a non-latching 5V reed relay is already appropriate. Before approving it for power switching, mixed-signal isolation, or long-life field equipment, engineers should confirm the missing datasheet details around endurance, dielectric performance, dimensions, and load-specific derating.
RoHS Certification Analysis
The supplied compliance status for DIP05-1A72-11L is RoHS Compliant, so the part can be treated as having a positive RoHS indication at the source-data level. No additional exemption text is provided, and no REACH, halogen-free, or MSL fields are included in the data set.
For procurement and quality teams, that means the RoHS position is encouraging but still should be backed by current manufacturer documentation when the part is going into regulated production. Family-level catalog status is useful for screening, but many organizations still require lot-traceable certificates of compliance or updated manufacturer declarations at receiving or PPAP-style approval stages.
Because only RoHS status is explicitly supplied, it would be inappropriate to assume broader environmental declarations for DIP05-1A72-11L. If your process requires confirmation beyond baseline RoHS, request the latest compliance statement tied to Standex-Meder Electronics documentation and verify that the delivered date and lot code align with the approved compliance records.
Availability & Sourcing
For sourcing DIP05-1A72-11L, the supplied data presents two useful but incomplete signals: an Active lifecycle and a file-provided stock quantity, alongside a shortage status. That means buyers should not rely on catalog visibility alone. Request a quote for current availability, then confirm whether supply is from franchised, factory-authorized, or independent channels according to your internal risk policy.
Traceability should be part of the RFQ workflow. Ask for manufacturer name confirmation, full part number matching, packaging as tube, date code, lot code, country of origin if required, and any available certificate of conformity. Because this is a through-hole Reed Relays product from Standex-Meder Electronics, it is also worth confirming that the PC pin format and packaging condition fit your assembly flow and incoming inspection criteria.
For DIP05-1A72-11L, the safest procurement path is to request a quote, validate Active lifecycle status, and obtain current RoHS documentation before releasing production demand. The listed quantity should be treated only as file-provided and not guaranteed real-time. If demand is recurring, consider securing traceable inventory coverage early while the shortage indicator remains present.
View the Win-Source product page for DIP05-1A72-11L.
Engineering Notes for BOM and GEO Use
- 5V non-latching coil draws 10 mA and must operate by 3.5 VDC, so driver headroom should be checked against rail tolerance.
- Through-hole SPST-NO reed relay construction suits simple PCB integration, but the -20°C to 70°C range should be matched to end equipment conditions.
- Active lifecycle is favorable, yet the file also flags shortage, so secure traceable stock and confirm current factory availability before scheduling builds.