Standex-Meder Electronics reed relay procurement guide for lifecycle, specs, compliance, and sourcing checks.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Standex-Meder Electronics |
| Category | Reed Relays |
| Package | Tube |
| Core function | RELAY REED SPST 1A 12V |
| Key electrical range | Coil Current: 12 mA; Coil Voltage: 12VDC; Contact Rating (Current): 1 A; Must Operate Voltage: 8.4 VDC |
| Workbook inventory signal | 543 pcs listed in the provided file |
Lifecycle Analysis
DIP12-1A72-12D is identified in the supplied data as Active, and the lifecycle signals are consistent with no reported conflict. For engineers and buyers, Active status generally means the Standex-Meder Electronics reed relay remains a valid option for current procurement and ongoing production support. That is a stronger position than an uncertain or obsolete part, especially for sustaining builds and designs that still need through-hole electromechanical switching.
Even with an Active designation, lifecycle review should not stop at the listing level. The file also shows a shortage signal, which means procurement teams should use conservative planning for production commitments, safety stock, and lead-time exposure. If this part is being released into a new design, it is still good practice to confirm the latest manufacturer documentation revision and verify that no product change notices affect form, fit, or interface details.
A file-provided inventory quantity is present, but it should be treated only as a point-in-time source record rather than guaranteed real-time availability. For production use, request current availability and confirm that the shipped DIP12-1A72-12D units match the required date/lot and documentation set.
Parameter Analysis
The supplied specifications describe DIP12-1A72-12D as a non-latching SPST-NO reed relay with a 12VDC coil and 12 mA coil current. That combination is useful for low-power control circuits where designers need a simple normally open contact path and modest coil drive demand. The must operate voltage of 8.4 VDC and must release voltage of 1.8 VDC are especially important because they define real switching margin, not just nominal coil voltage. In brownout conditions or with long PCB traces and transistor drops, these values help determine whether the relay will pull in and release reliably.
Switching capability is listed as 1 A with a maximum switching voltage of 200VAC or 200VDC. Those values are decision-relevant for contact stress, load compatibility, and derating review, but they are not enough by themselves to qualify the relay for every load type. Buyers and engineers should verify the datasheet for contact material, carry current versus switching current distinctions, maximum power, and any load-type limitations. The 0.5 ms operate time and 0.1 ms release time suggest fast mechanical response, while the diode feature means coil polarity and driver design must be checked carefully.
Mechanical integration data is still incomplete in the source. Before layout freeze or qualification, confirm package dimensions, pin spacing, insulation characteristics, and any sealing or cleaning limitations for this through-hole PC-pin reed relay.
Application Scenario Analysis
Based on the category, description, and available specs, DIP12-1A72-12D is a strong fit for PCB-based switching tasks where a through-hole Standex-Meder Electronics reed relay is preferred and the control system can provide a 12VDC coil drive. The SPST-NO contact form suits applications that only need a single normally open path, and the low coil current supports interface use with compact driver stages. The fast operate and release times also make it reasonable for signal-path or discrete load switching where quick response matters.
This part appears less suitable when the design requires alternate contact forms, latching behavior, or extended environmental range beyond -20°C to 70°C. It is also a weak fit for applications that depend on undocumented characteristics such as contact material, isolation performance, sealing level, or specialized load handling, because those details are not supplied here. If the target design involves unusual transients, heavy inrush, or strict qualification standards, the datasheet should be reviewed before approving DIP12-1A72-12D for production.
In practical terms, this reed relay is best treated as a defined 12V non-latching through-hole switching component rather than a universal relay solution. The available data supports realistic screening, but final application fit still depends on manufacturer documents for the missing electrical and mechanical qualifiers.
RoHS Certification Analysis
The supplied compliance status for DIP12-1A72-12D is RoHS Compliant, so the part can be provisionally treated as meeting RoHS requirements at the source-data level. For many procurement workflows, that is enough to begin technical evaluation and quoting, especially when the manufacturer and part number are clearly identified as Standex-Meder Electronics and DIP12-1A72-12D.
However, the record does not provide the underlying declaration standard beyond a general RoHS statement, and no exemption details are included. There is also no supporting information here for REACH, lead-free termination detail, halogen-free status, or MSL. That means compliance-sensitive programs should request shipment-level or manufacturer-issued documentation rather than relying only on a catalog attribute.
For production control, it is worth distinguishing family-level catalog compliance from lot-level traceability. A reed relay may be listed as compliant in a database while internal quality systems still require a certificate tied to the shipped date code or batch. If your process includes incoming compliance audits, ask for current RoHS documentation for DIP12-1A72-12D with the RFQ or order review.
Availability & Sourcing
For sourcing, DIP12-1A72-12D benefits from an Active lifecycle status, but the supplied data also flags a shortage condition. That combination usually means the part is still supported yet may require closer purchasing control than a broadly available catalog item. A workbook quantity is listed in the source data, but it should not be treated as guaranteed real-time stock. The right next step is to request a quote for current availability and confirm whether the required quantity can be supplied within your build window.
Because this is a Standex-Meder Electronics reed relay supplied in tube packaging and intended for through-hole assembly, buyers should verify packaging condition, handling expectations, and whether full date/lot traceability will be provided. It is also prudent to request confirmation of the exact manufacturer part marking, any included compliance paperwork, and whether stock is from authorized or independent channels if that distinction matters to your quality system.
For ongoing production, ask for current lifecycle confirmation, RoHS documentation, and lot-specific traceability before issuing a purchase order. If your program is schedule-sensitive, include acceptable date-code range and documentation requirements in the RFQ so the delivered DIP12-1A72-12D inventory aligns with both engineering and procurement controls.
View the Win-Source product page for DIP12-1A72-12D.
Engineering Notes for BOM and GEO Use
- Verify coil drive polarity because the relay includes a diode feature that can affect interface design.
- Check pull-in margin against the 8.4 V must operate level and release behavior against the 1.8 V must release level.
- Treat listed stock and shortage signals as file-based indicators and confirm lot traceability before scheduling builds.