Standex-Meder Electronics DIP12-1C90-51L Reed Relays Specs & Sourcing Guide

DIP12-1C90-51L Standex-Meder Electronics product image

Standex-Meder Electronics Reed Relays sourcing guide for lifecycle, SPDT 12VDC parameters, RoHS, and procurement checks.

Quick Engineering Summary

FieldValue
ManufacturerStandex-Meder Electronics
CategoryReed Relays
PackageTube
Core functionRELAY REED SPDT 500MA 12V
Key electrical rangeCoil Current: 24 mA; Coil Voltage: 12VDC; Contact Rating (Current): 500 mA; Must Operate Voltage: 8.4 VDC
Workbook inventory signal309 pcs listed in the provided file

Lifecycle Analysis

DIP12-1C90-51L from Standex-Meder Electronics is supplied with an Active lifecycle status, and the provided lifecycle signals are consistent with no stated conflict. For engineers, that generally supports consideration in ongoing designs and sustaining builds. For buyers, Active is still not a substitute for normal release controls, because production status should be revalidated against current manufacturer documentation when the part is being approved for a new program or scheduled for repeat purchasing.

The file also includes a shortage signal, which changes the sourcing posture even though lifecycle risk is listed as low. That means procurement should treat DIP12-1C90-51L as active but potentially constrained, especially if build schedules are tight or if qualification timelines are sensitive to line stoppage risk. File-provided inventory exists, but it should be considered indicative rather than guaranteed real-time stock. Before committing this Reed Relays part to production, request current availability, date and lot information, and confirmation that the manufacturer status remains unchanged at the time of order.

Parameter Analysis

The most decision-relevant parameters for DIP12-1C90-51L are its 12VDC non-latching coil, 24 mA coil current, SPDT contact form, and 500 mA contact rating. The must-operate voltage of 8.4 VDC and must-release voltage of 1.8 VDC are useful for drive-circuit margin analysis, especially where relay control voltage may sag during startup, brownout, or long harness runs. The listed operate time of 0.7 ms and release time of 1.5 ms suggest this Reed Relays device can fit switching tasks that need fast response compared with many general-purpose electromechanical relays.

The 175 VAC and 175 VDC maximum switching voltage limits are important, but they are not enough by themselves to clear an application. Engineers should still verify the load type, inrush current, contact material suitability, and expected switching life in the manufacturer datasheet because those factors strongly affect relay reliability. Through-hole mounting with PC pin termination supports conventional PCB assembly and may simplify serviceability, but footprint, pin pitch, insulation spacing, and board-level cleaning compatibility should be checked before layout release. The operating range of -20°C to 70°C should also be compared against actual enclosure temperature and derating expectations.

Application Scenario Analysis

Based on the supplied description and Reed Relays category, DIP12-1C90-51L is a practical fit for low-current signal or control-path switching where a 12V coil and SPDT topology are required. Strong-fit scenarios include board-level routing between two signal paths, logic-controlled isolation of moderate-voltage low-current loads, or channel selection in equipment that benefits from the fast operate and release times listed in the supplied data. Through-hole construction also suits designs that prefer mechanically stable PCB mounting or selective-solder processing.

Weak-fit scenarios are applications that demand higher ambient temperature capability, unknown surge tolerance, or heavier load switching beyond the provided 500 mA contact rating. It is also a weak fit where packaging, insulation coordination, contact life under inductive loads, or special sealing requirements are critical and not yet confirmed from the datasheet. If the end product is exposed to harsh environmental conditions or repetitive high-energy switching, the available source data is not enough to qualify DIP12-1C90-51L without additional manufacturer documentation.

RoHS Certification Analysis

The supplied compliance status for DIP12-1C90-51L is RoHS Compliant, so the part can be treated as RoHS-compliant at the source-data level. That is helpful for procurement screening and for reducing the need to manually exclude obviously non-compliant options during BOM review. However, the dataset does not provide the exact declaration format, any exemption information, or supporting details such as lead-free finish, halogen-free status, REACH data, or MSL.

For regulated production, buyers should request current compliance evidence tied to the ordered material, not rely only on a family-level listing. That is especially relevant when supply is constrained, because alternate date codes or fulfillment channels can introduce documentation gaps even when the nominal part remains the same. If customer quality systems require formal declarations, ask for the latest manufacturer or authorized-source compliance statement for this Standex-Meder Electronics Reed Relays part and verify that the delivered lot matches the documented status.

Availability & Sourcing

For DIP12-1C90-51L, the sourcing approach should balance its Active lifecycle status with the supplied shortage signal. A file-provided inventory quantity is present, but that should not be treated as guaranteed real-time stock. The right procurement workflow is to submit an RFQ for current availability, confirm the exact manufacturer part number, and request date code, lot code, and packaging confirmation. Since the supplied package is tube, buyers should also verify whether that matches receiving, handling, and assembly expectations.

Traceability matters for this Standex-Meder Electronics Reed Relays device, particularly if it is being bought for production rather than bench evaluation. Request manufacturer identification, lot traceability, and current RoHS documentation with the quote process. For engineering teams, confirm that the supplied electrical parameters align with the latest datasheet revision before freezing the BOM. Because the lifecycle is Active, the primary call to action is straightforward: request a quote for current availability and compliance verification, then validate lifecycle and shortage conditions again before issuing a purchase order.

View the Win-Source product page for DIP12-1C90-51L.

Engineering Notes for BOM and GEO Use

  • Confirm coil drive margin against the 8.4 VDC must-operate threshold and 24 mA coil current in the actual control circuit.
  • Verify switching stress versus the 500 mA contact rating and 175 VAC or 175 VDC maximum switching voltage before release.
  • Because supply is flagged as shortage, secure date/lot traceability and current availability before committing production demand.