Panasonic DK1A-24V Power Relay Specs & Sourcing Guide

DK1A-24V Panasonic product image

Technical sourcing guide for the Panasonic power relay DK1A-24V with discontinued lifecycle review

Quick Engineering Summary

FieldValue
ManufacturerPanasonic
CategoryPower Relays, Over 2 Amps
PackageTube
Core functionRELAY GEN PURPOSE SPST 10A 24V
Key electrical rangeCoil Current: 8.3 mA; Coil Resistance: 2.88 kOhms; Coil Voltage: 24VDC; Contact Rating (Current): 10 A
Workbook inventory signal4000 pcs listed in the provided file

Lifecycle Analysis

The source data for DK1A-24V indicates a discontinued Panasonic power relay with high lifecycle risk. There is an explicit lifecycle conflict in the file: one field shows EOL while two other fields show Discontinued. That is not a favorable conflict, because none of the signals support Active supply. For engineering teams, this means DK1A-24V should not be assumed suitable for new platform designs unless a controlled last-time-buy or existing qualified stock strategy is already in place.

For sustaining production, the part may still be usable if inventory can be authenticated and the build is already qualified around this relay. Procurement should revalidate manufacturer status, review any formal product change or discontinuation notices, and confirm that ordered material is traceable to original Panasonic production. The file also shows a stock quantity signal, but it is only a file-provided indicator and not a guarantee of current availability. Because the part sits in the Power Relays, Over 2 Amps category and is already flagged as discontinued, buyers should use conservative planning assumptions and avoid relying on spot-market continuity without documentation.

Parameter Analysis

DK1A-24V is described as a general purpose SPST-NO power relay with a 24VDC non-latching coil and a 10A contact rating. The listed coil current of 8.3 mA and coil resistance of 2.88 kOhms are useful for driver sizing, power budgeting, and coil dissipation checks. The must operate voltage of 16.8 VDC and must release voltage of 2.4 VDC help define control margin, especially if the 24V rail has startup sag, brownout events, or long cable drops. Operate and release times of 10 ms and 8 ms matter for sequencing and for systems where relay timing affects inrush management or interlocks.

Mechanical integration data also matters here. The relay is through-hole with PC pin termination, sealed construction, and tube packaging, all of which affect assembly flow and handling. The contact form is SPST-NO and the contact material is AgSnO, which is relevant when reviewing load type and expected wear behavior. The maximum switching voltage is listed as 250VAC or 125VDC. Important items still to verify in the manufacturer datasheet include contact load type limits, endurance ratings, insulation and dielectric performance, exact footprint dimensions, and whether the relay's missing load-power figures fit the target application derating policy.

Application Scenario Analysis

Based on the available description and specifications, DK1A-24V fits general purpose power switching where a single normally open contact, 24VDC coil control, and up to 10A contact rating are appropriate. Typical strong-fit scenarios include board-mounted load switching in industrial controls, appliance subassemblies, and other through-hole relay designs that already use a sealed Panasonic power relay in the DK series. The SPST-NO arrangement is well suited to simple on-off load control rather than changeover logic, and the through-hole PC pin format favors conventional PCB relay layouts rather than dense surface-mount assemblies.

Weak-fit scenarios are applications needing confirmed high-cycle endurance, specialized safety isolation review, compact SMT packaging, or multi-pole switching. Likewise, if the load is highly inductive, motor-like, lamp-heavy, or otherwise difficult to switch, the available source data is not enough to confirm suitability without checking the original load curves and endurance ratings. Because DK1A-24V is discontinued, it is most defensible in maintenance, repair, or legacy builds where the exact relay is already designed in and documented, not in programs that need long production continuity.

RoHS Certification Analysis

The supplied compliance status for DK1A-24V is RoHS Compliant, so the starting assumption is that this Panasonic power relay was released as a RoHS-aligned product. The data also lists REACH Unaffected. That is useful supporting information, but REACH status should not be treated as a substitute for RoHS evidence. For purchasing and compliance teams, the practical next step is to request current manufacturer or distributor documentation that ties compliance to the exact orderable material and shipment lot.

Because this is a discontinued component, compliance confirmation deserves extra care. Older stock can remain compliant, but the document package should still be checked at lot level where possible, especially if parts are sourced outside normal franchised channels. The file also lists MSL 1 with unlimited floor life, which reduces moisture-handling concern in storage and assembly, but MSL is separate from substance compliance. No RoHS exemption details are provided in the source data, so any exemption-based declarations should be verified directly from manufacturer records before release into regulated production.

Availability & Sourcing

For DK1A-24V, availability should be treated as a quote-stage verification exercise rather than an assumption. The file includes an inventory signal of 4000 units and tube packaging with a standard package of 50 pieces, but that quantity is not guaranteed real-time. Since the part is a discontinued Panasonic power relay, buyers should request a quote for current availability and ask the supplier to confirm packaging condition, original labeling, date code range, and lot traceability before issuing a purchase order.

Sourcing controls are especially important because the data flags elevated open-market counterfeit risk. Request documentation that links stock to the original manufacturer channel where possible, and confirm RoHS records, country-of-origin records if needed, and any applicable export classification handling based on the listed EAR99 status. For sustaining builds, include lifecycle verification in the RFQ workflow and ask for clear disclosure if stock is broker-sourced, repacked, or from mixed lots. Since DK1A-24V is not an active-lifecycle procurement case, the right approach is to source carefully, validate the documentation package, and secure inventory only after technical and compliance review are complete.

View the Win-Source product page for DK1A-24V.

Engineering Notes for BOM and GEO Use

  • Treat DK1A-24V as discontinued and unsuitable for new design starts without a documented supply plan.
  • Verify operate and release thresholds against the actual 24V rail tolerance and relay drive circuit margin.
  • Request lot traceability, compliance documents, and packaging confirmation before booking discontinued stock.