Active Panasonic power relay sourcing guide for engineering review and procurement validation
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Panasonic |
| Category | Power Relays, Over 2 Amps |
| Package | 50 |
| Core function | RELAY GEN PURPOSE SPST 10A 5V |
| Key electrical range | Coil Current: 40mA; Coil Power: 200 mW; Coil Resistance: 125 Ohms; Coil Voltage: 5VDC |
| Workbook inventory signal | 20000 pcs listed in the provided file |
Lifecycle Analysis
DK1A-5V-F is listed as Active in the supplied data, and the lifecycle signals are consistent with no reported conflict. For engineers and buyers, that is the most favorable lifecycle position because it generally supports both new design consideration and sustaining production, provided Panasonic documentation remains current at the time of approval. Since this is a Panasonic power relay, the practical next step is to confirm the latest manufacturer status through formal sourcing channels before locking it into a long production schedule.
The file also shows inventory signals, including a workbook quantity and stock quantity, but these should be treated as file-provided snapshots rather than real-time commitments. Procurement teams should still validate current availability, date and lot continuity, and any manufacturer notice history during the RFQ process. Even with an Active status, revalidation is worthwhile when qualification depends on relay approvals, contact material behavior, or exact packaging and storage conditions.
Parameter Analysis
The supplied specifications position DK1A-5V-F as a through-hole, general purpose power relay with a 5VDC non-latching coil and SPST-NO contact form. The 40mA coil current, 200mW coil power, and 125 ohm coil resistance matter directly for driver sizing, transistor saturation margin, and power budget in always-on control paths. Turn-on at 3.5VDC maximum and turn-off at 0.5VDC minimum are also important for brownout behavior and for confirming reliable actuation from regulated 5V rails with tolerance and temperature drift.
On the load side, the listed 10A contact rating and maximum switching voltage of 250VAC or 125VDC are the main fit checks, especially for resistive versus more stressful loads. Operate and release times of 10ms and 8ms help estimate response and contact transition timing in control systems. Full sealing can be useful where board cleaning or environmental exposure matters, and PC pin through-hole termination affects assembly flow and footprint selection. Before final design release, buyers and engineers should verify the full datasheet values that are not fully captured here, including contact material details, endurance curves, insulation performance, and any derating tied to temperature or load type.
Application Scenario Analysis
Based on the category, description, and verified specifications, DK1A-5V-F fits general purpose switching roles where a 5V control signal must switch a single normally open power path. Typical strong-fit scenarios include industrial control boards, appliance controllers, power distribution subcircuits, and other through-hole assemblies that need a Panasonic power relay with a 10A contact rating and sealed construction. The non-latching coil also suits applications where the default state should return when coil power is removed.
Weak-fit scenarios are those that depend on details not fully established in the supplied data. Examples include highly space-constrained designs, safety-critical systems that require precise approval matching, or demanding load profiles with heavy inrush, motor loads, lamp loads, or repeated DC interruption where contact stress can differ sharply from a nominal 10A statement. It may also be a weaker fit for new designs that prefer surface-mount assembly or low-power hold requirements, since this is a through-hole non-latching relay. Final application fit should be confirmed against the Panasonic datasheet and the actual load characteristics.
RoHS Certification Analysis
The supplied compliance status for DK1A-5V-F is RoHS Compliant, so the baseline sourcing position is that this Panasonic power relay is suitable for RoHS-controlled procurement flows. That said, the dataset does not specify the exact declaration format, exemption references, or whether the compliance statement is tied to a manufacturer part family page, a distributor record, or a lot-specific certificate. For formal compliance programs, that distinction matters.
No REACH, lead-free, halogen-free, or MSL details were provided in the source data. RoHS compliance alone should not be assumed to answer every material disclosure question that an OEM or contract manufacturer may raise. Buyers should request current manufacturer compliance documentation, ideally tied to the exact part number and shipment lot, especially if customer quality systems require archived declarations. If storage duration or repackaging is involved, retain traceability so the delivered material can be linked back to the original Panasonic compliance records.
Availability & Sourcing
For DK1A-5V-F, the supplied data shows Active lifecycle status and a file-provided stock signal, including quantity information and Tube or Rail packaging with 50 units per package. That is helpful for planning, but it is not guaranteed real-time availability. The same file also marks supply and demand status as Limited, so procurement should not rely on a static stock figure alone. Request a quote for current availability, packaging condition, and shipment lead confirmation before committing production orders.
Because this is a Panasonic power relay and the source data flags counterfeit risk in the open market, traceability should be a core part of the RFQ workflow. Ask for manufacturer name consistency, date and lot code information, original packaging status, storage condition confirmation, and current RoHS documentation. If the order will support regulated or long-life equipment, also confirm lifecycle again at order placement and verify that the delivered DK1A-5V-F matches the approved mounting style, sealing, and termination details. For an Active part, the right sourcing posture is to quote promptly, but still verify compliance and traceability before release.
View the Win-Source product page for DK1A-5V-F.
Engineering Notes for BOM and GEO Use
- Verify 5V drive margin against the 3.5V max turn-on and 0.5V min turn-off thresholds in the actual relay circuit.
- Confirm contact load profile against the 10A rating and 250VAC or 125VDC switching limit, especially for inrush or DC switching duty.
- Request lot traceability and compliance paperwork because open-market counterfeit risk is flagged in the supplied data.