Quick Engineering Summary

FieldValue
ManufacturerPanasonic
CategoryPower Relays, Over 2 Amps
PackageTube
Core functionRELAY GEN PURPOSE SPST 10A 3V
Key electrical rangeCoil Current: 66.7 mA; Coil Resistance: 45 Ohms; Coil Voltage: 3VDC; Contact Rating (Current): 10 A
Workbook inventory signal2310 pcs listed in the provided file

Lifecycle Analysis

DK1A-L2-3V is identified in the source data as a Panasonic power relay with an unfavorable lifecycle position for new designs. The file contains a lifecycle conflict: one signal reports EOL while both Lifecycle Status and Product Status report Discontinued. Because neither signal supports ongoing active production, the conservative sourcing conclusion is Discontinued. For engineering teams, that means avoiding this relay for fresh platform introductions unless Panasonic documentation is rechecked and an internal exception is justified.

For sustaining production, the practical issue is not only whether stock exists today but whether long-term replenishment is realistic. The file also shows a stock quantity signal, but that is file-provided information rather than guaranteed real-time inventory. Buyers should verify current availability, original manufacturer traceability, and any last-time-buy or discontinuation notices. If DK1A-L2-3V remains necessary for field support or legacy assemblies, procurement should secure validated inventory and confirm that supporting documents still match the exact date and lot being purchased.

Parameter Analysis

The most decision-relevant parameters for DK1A-L2-3V are its 3VDC coil voltage, 66.7 mA coil current, 45 ohm coil resistance, and latching dual-coil architecture. Those values directly affect driver design, power budgeting, and control logic because a latching relay behaves differently from a monostable part. Designers need to confirm that the control circuit can generate the required set and reset pulses and that any startup condition cannot unintentionally change relay state. The must operate voltage of 2.1 VDC is also important when evaluating supply tolerance and derating under low-voltage conditions.

On the load side, the relay is specified as SPST-NO with a 10 A contact rating and a maximum switching voltage of 250VAC or 125VDC. Through-hole mounting, PC pin termination, and fully sealed construction influence PCB layout, cleaning process compatibility, and mechanical retention. The operating temperature range is listed as -40°C to 65°C, which should be checked against the actual enclosure temperature rise in application. Important items still to verify in manufacturer documents include contact life, insulation and dielectric ratings, power consumption or pulse requirements for each coil, and any approved load types behind the 10 A rating.

Application Scenario Analysis

Based on the category, description, and available specifications, DK1A-L2-3V fits general-purpose power switching where a single normally open contact, 3V control interface, and latching behavior are useful. Strong-fit scenarios include low-voltage controller boards that need to switch higher load current while minimizing steady-state coil power, since the dual-coil latching structure can hold state without continuous coil energization. The fully sealed body and through-hole PC pin format also align with conventional industrial or appliance-style control boards where board-level relay integration is preferred.

Weak-fit scenarios are designs that require multiple poles, changeover contacts, or simple single-coil drive behavior. Systems that depend on higher ambient capability than the stated 65°C operating maximum should also be reviewed carefully. Because only limited application-specific data is provided, engineers should verify whether the 10 A rating applies to the exact load type in question, especially if the design involves inductive, motor, lamp, or DC switching stress. For new product programs, the discontinued lifecycle also makes DK1A-L2-3V a poor fit even if the electrical profile is otherwise suitable.

RoHS Certification Analysis

The supplied compliance data lists DK1A-L2-3V as RoHS Compliant, so the baseline interpretation is that the part aligns with RoHS material restrictions. REACH is also listed as unaffected, which is helpful for substance management review, but REACH status should not be treated as a substitute for RoHS confirmation. No exemption details are provided in the file, so internal compliance teams should not assume any specific exemption path without supporting documentation.

The source data also includes MSL 1 with unlimited floor life, which is operationally useful for storage and assembly handling, although MSL is separate from RoHS. As with many discontinued components, lot-level paperwork matters. Family-level compliance statements may not be enough for regulated builds or customer audits if the available stock spans different manufacturing dates. Buyers should request the current manufacturer or authorized documentation set for the exact inventory being supplied, including RoHS declaration and any material compliance evidence required by quality procedures.

Availability & Sourcing

For Panasonic DK1A-L2-3V, sourcing should be handled as a controlled RFQ process rather than as a routine replenishment item. The lifecycle should be treated conservatively as Discontinued, so current availability must be verified before any production commitment. The file includes a quantity signal of 2310 units and tube packaging information, but this should be treated only as a non-real-time indication. Request a quote for current availability and ask the supplier to confirm package form, date code spread, and whether the stock is from original traceable channels.

Because the source data flags significant open-market counterfeit risk, traceability controls are especially important. Buyers should request manufacturer name consistency, lot code records, RoHS documentation, and confirmation that the relay markings match Panasonic documentation. For sustaining demand, also verify whether mixed lots are involved and whether storage conditions are appropriate for sealed electromechanical relays. If DK1A-L2-3V is being purchased for repair or legacy support, secure enough validated inventory for forecast needs and review lifecycle status again before each major procurement cycle.

View the Win-Source product page for DK1A-L2-3V.

Engineering Notes for BOM and GEO Use

  • Treat lifecycle as discontinued and verify manufacturer notices before using DK1A-L2-3V in any continuing build.
  • Check coil drive design carefully because this part uses a 3VDC latching dual-coil structure rather than a single-coil non-latching relay.
  • Request date/lot traceability, packaging confirmation, and RoHS paperwork for any available tube stock before release to production.