Active Panasonic power relay sourcing view for engineering and procurement teams
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Panasonic |
| Category | Power Relays, Over 2 Amps |
| Package | Box |
| Core function | RELAY GEN PURPOSE SPST 10A 5V |
| Key electrical range | Coil Current: 40 mA; Coil Voltage: 5VDC; Contact Rating (Current): 10 A; Must Operate Voltage: 3.5 VDC |
| Workbook inventory signal | 2500 pcs listed in the provided file |
Lifecycle Analysis
DK1A-L2-5V-F is identified in the supplied data as Active, and the lifecycle signals are consistent with no stated conflict. For engineers, that supports consideration in current builds more confidently than an NRND or end-of-life relay, especially where Panasonic documentation and qualification history are already accepted by the program. For buyers, Active status generally means normal manufacturer support remains in place, but it does not remove the need to confirm current lead time, packaging, and revision control.
The file also shows a shortage signal, which introduces a practical sourcing risk even though lifecycle risk is low. That means DK1A-L2-5V-F may still be acceptable for new or sustaining demand, but procurement should validate current availability and manufacturer-backed supply continuity before committing to production dates. A workbook quantity is present in the source file, yet it should be treated as a non-real-time inventory indicator rather than guaranteed stock. Before release, confirm the latest Panasonic part status, any applicable product change notifications, and whether the exact approval-marked version required by the end equipment remains available.
Parameter Analysis
The supplied specifications position DK1A-L2-5V-F as a general purpose power relay with SPST-NO contact form, 10A contact rating, and maximum switching limits of 250VAC or 125VDC, with load figures listed as 2500VA and 1250W. Those are the primary fit parameters for checking whether the relay matches the intended load type, voltage domain, and inrush profile. The contact material is silver tin oxide, which is commonly relevant when evaluating switching durability and load compatibility, while the fully sealed construction can matter for cleaning exposure and environmental handling during assembly.
On the control side, the relay uses a 5VDC latching dual-coil design with 40 mA coil current and a must-operate voltage of 3.5 VDC. That makes drive-circuit compatibility a key review item because latching behavior is not interchangeable with non-latching relay logic. Through-hole mounting and PC pin termination affect footprint and assembly flow, and the operating range of -40°C to 65°C should be checked against enclosure temperature rise and derating policy. Important missing items to verify in the Panasonic datasheet include coil resistance or power, insulation and dielectric ratings, contact resistance, mechanical dimensions, and endurance data under the actual load case.
Application Scenario Analysis
Based on the category, description, and relay specifications, DK1A-L2-5V-F is a strong fit for general purpose power switching where a single normally open contact is sufficient and where a 5V control domain is available. Typical engineering scenarios include board-level switching of AC or DC loads within the stated switching limits, especially where latching behavior is useful for reducing steady-state coil power. The through-hole format and PC pins also make it suitable for conventional PCB-mounted power relay sections rather than dense fine-pitch control boards.
It is a weaker fit for applications that need changeover contacts, multiple poles, or simple non-latching drive semantics. It is also not the best candidate when the design requires higher operating temperature margin than the stated 65°C upper limit, or when the control circuitry cannot reliably generate the proper set and reset pulses for a dual-coil latching relay. Because the provided data does not include endurance curves, isolation figures, or surge behavior, engineers should be cautious about using DK1A-L2-5V-F in heavily inductive, high-inrush, or safety-critical switching roles until those datasheet details are confirmed.
RoHS Certification Analysis
The supplied compliance status for DK1A-L2-5V-F is RoHS Compliant, so the most conservative interpretation is that the part meets the seller-provided RoHS requirement at a family or listed-part level. For many procurement workflows, that is enough to proceed to quotation and document collection, especially when the Panasonic power relay is being sourced for assemblies that already require RoHS controls.
That said, the source does not provide the exact RoHS revision statement, exemption details, REACH information, halogen-free status, or moisture sensitivity data. RoHS status should therefore be backed by the current manufacturer declaration or distributor compliance certificate at the lot level if your customer, region, or internal quality system requires traceable evidence. Compliance can vary by manufacturing date, labeling, or document revision, so buyers should request the latest compliance paperwork for the exact DK1A-L2-5V-F stock being offered rather than relying only on a catalog-level statement.
Availability & Sourcing
For sourcing DK1A-L2-5V-F, the most practical path is an RFQ process that confirms current stock position, lead time, factory packaging, and traceability. The source file shows inventory and also indicates shortage, so availability should be treated as dynamic. Request a quote for current availability and ask the supplier to confirm whether the offered Panasonic power relay stock is from authorized channels or otherwise fully traceable to manufacturer origin.
At order placement, verify date code, lot code, packaging condition, and whether the exact box or handling configuration matches your receiving and assembly needs. Also confirm the lifecycle status remains Active at the time of purchase and request RoHS documentation tied to the offered lot when compliance evidence is required. Because DK1A-L2-5V-F is a latching relay, buyers should make sure the internal engineering description on the PO matches the dual-coil latching variant exactly, reducing the risk of receiving a relay with the wrong operating behavior. File-provided quantity should be used only as a planning clue and not as guaranteed real-time inventory.
View the Win-Source product page for DK1A-L2-5V-F.
Engineering Notes for BOM and GEO Use
- Verify dual-coil latching drive behavior in the control circuit before layout release.
- Check contact load profile against the 10A rating and 250VAC or 125VDC switching limits.
- Treat listed inventory as a file snapshot and confirm lot code, approvals, and compliance documents at RFQ.