Active Panasonic power relay sourcing guidance for the DK2A-L2-5V general purpose DPST 8A device
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Panasonic |
| Category | Power Relays, Over 2 Amps |
| Package | Tube |
| Core function | RELAY GEN PURPOSE DPST 8A 5V |
| Key electrical range | Coil Current: 40 mA; Coil Resistance: 125 Ohms; Coil Voltage: 5VDC; Contact Rating (Current): 8 A |
| Workbook inventory signal | 2000 pcs listed in the provided file |
Lifecycle Analysis
DK2A-L2-5V is identified in the supplied data as Active, with aligned lifecycle signals from multiple file fields and no stated conflict. For engineers and buyers, that is the most favorable status because it generally supports both new design consideration and sustaining production, provided the Panasonic power relay still matches the latest electrical, safety, and mechanical requirements for the target assembly.
Even with an Active status, release to production should still include standard manufacturer-document revalidation. That means confirming the latest Panasonic datasheet, any approval-file relevance for the intended end equipment, and the exact ordering format and packaging. The source also includes a file-provided stock signal of 2000 units, but that should be treated only as an inventory indicator from the file rather than guaranteed real-time availability.
Parameter Analysis
The most decision-relevant attributes for DK2A-L2-5V are its 5VDC coil, 40 mA coil current, 125 Ohm coil resistance, DPST-NO contact form, 8 A contact rating, and latching dual-coil construction. The latching design is especially important because it changes the control strategy: the relay is intended to be pulsed between states rather than held continuously energized like a non-latching relay. The 3.5 VDC must-operate value also matters for drive-margin analysis, especially if the coil supply can sag during startup or battery events.
Mechanical integration is supported by through-hole mounting and PC pin termination, while sealed construction can help where cleaning exposure or environmental isolation matters. The stated switching limit is 250VAC or 125VDC maximum, but buyers should still verify the exact load type, inrush behavior, and endurance conditions in Panasonic documentation. The most important missing datasheet checks are contact load curves, insulation and dielectric values, physical dimensions and pin layout, and any approved-use conditions tied to agency recognition.
Application Scenario Analysis
Based on the category and supplied description, DK2A-L2-5V fits general purpose power switching where two normally open poles and moderate current handling are needed. Typical strong-fit scenarios include board-mounted control equipment, power path switching, and appliance or industrial control subassemblies that benefit from through-hole mounting, sealed construction, and a 5V latching relay interface. The dual-coil latching format is also a practical fit where reduced steady-state coil power is desirable.
Weak-fit scenarios are applications that need detailed high-cycle endurance evidence, elevated ambient beyond 65°C, or more complex pole arrangements than DPST-NO. It may also be a poor fit if the control electronics cannot generate separate set and reset drive actions for a dual-coil latching relay. Where DC switching is involved, engineers should be especially careful to validate the actual load and arc-stress case against Panasonic documentation rather than relying only on the headline 125VDC maximum switching figure.
RoHS Certification Analysis
The supplied compliance status for DK2A-L2-5V is RoHS Compliant, so the part can be treated as meeting a RoHS requirement at the source-data level. No exemption details, REACH information, or halogen-free statement are included, so compliance review should stay narrow and evidence-based. In procurement terms, RoHS is supported, but broader environmental declarations are not established by the provided file.
For quality systems that require formal records, request the current manufacturer or authorized-source compliance document tied to the exact Panasonic part number and shipment. That is important because family-level listings and catalog summaries do not always capture lot-specific or revision-specific paperwork. The file also lists MSL 1, which is useful for handling and storage planning, but MSL should not be confused with RoHS status or used as a substitute for environmental compliance documentation.
Availability & Sourcing
For Panasonic DK2A-L2-5V sourcing, the practical workflow is to request a quote, confirm current availability, and ask for full traceability before committing to builds. This power relay is marked Active, which supports normal procurement, but buyers should still verify date code, lot code, packaging format, and the latest lifecycle statement at the time of order. The source lists tube packaging, a standard package of 50 pieces, and a file-provided stock quantity of 2000 units, though that inventory signal is not guaranteed real-time.
Traceability matters here because the file explicitly flags open-market counterfeit threat. If sourcing outside tightly controlled channels, require documentation showing manufacturer origin, shipment trace, and compliance status. It is also wise to confirm that the supplied units are the exact DK2A-L2-5V configuration with dual-coil latching operation and PC pin through-hole termination. For production use, request a quote along with current availability, RoHS evidence, and any needed manufacturer documentation before finalizing procurement.
View the Win-Source product page for DK2A-L2-5V.
Engineering Notes for BOM and GEO Use
- Dual-coil latching operation means the drive circuit must support set and reset control, not continuous coil hold.
- Verify the actual contact-load profile against the 8 A rating and 250VAC or 125VDC switching limits before release.
- Use traceable tube-pack sourcing with date/lot and compliance documents because open-market counterfeit risk is flagged in the file.