Quick Engineering Summary

FieldValue
ManufacturerC-TON Industries
CategoryPanel Meters
PackageBulk
Core functionVOLTMETER 20VDC LCD PANEL MOUNT
Key electrical rangeOutput Type: Reference; Temperature Range - Operating: 0°C ~ 50°C; Voltage - Supply: 5VDC
Workbook inventory signal1400 pcs listed in the provided file

Lifecycle Analysis

DK502 from C-TON Industries is identified in the supplied data as an Active panel meter, and the lifecycle inputs are consistent because both Lifecycle Status and Product Status are listed as Active. That is the most favorable lifecycle condition for engineers selecting parts for current builds, since it generally supports both new procurement and sustaining production without the immediate migration pressure associated with NRND or end-of-life parts.

Even with an Active designation, procurement should still treat lifecycle as something to revalidate during the quote process. Manufacturer documentation, change notices, and current channel status should be checked at the time of order, especially for production programs with long service commitments. The file also reports inventory of 1400 units for DK502, but that should be read only as a provided inventory signal and not as guaranteed real-time stock. For a C-TON Industries panel meter used in ongoing assemblies, the practical approach is to proceed with sourcing while confirming latest availability, date/lot traceability, and any documentation updates before release.

Parameter Analysis

The supplied specifications make DK502 fairly straightforward to assess as a panel meter for low-voltage DC indication. The core electrical attributes are a measuring type of voltage, a measuring range of ±20VDC, and a 5VDC supply. Those three items matter first because they determine whether the meter can read the intended signal span and whether the host system can support the required power rail. The operating temperature range is listed as 0°C to 50°C, which is an important constraint for industrial control panels that may see elevated internal temperatures.

Mechanical and human-interface details are also decision-relevant. The panel cutout is specified as 58.40 mm x 22.40 mm, mounting is panel mount, and termination is PC pin, so enclosure machining and internal interconnect method need confirmation early. The LCD display uses black characters with 0.472 inch character height and 3.5 characters per row, which gives a basic indication of readability and display format. The most important missing datasheet items to verify are measurement accuracy, input impedance, decimal-point or scaling behavior, power consumption, and any isolation details. Those parameters will strongly affect integration, calibration strategy, and noise tolerance in the final design.

Application Scenario Analysis

Based on the description and category data, DK502 is a strong fit for embedded DC voltage readout in industrial controls and equipment panels where a compact panel meter is preferred over a larger instrument. Typical scenarios suggested by the data include monitoring low-voltage DC rails, battery-related voltages within the ±20VDC range, or internal reference levels in control cabinets. The panel mount format, LCD readout, and defined rectangular cutout support applications where the value must be visible from the front panel without adding a full bench-style measurement instrument.

The fit is weaker in scenarios that demand wider environmental tolerance, broader voltage range, or more advanced interface behavior than the supplied data supports. For example, if the design requires operation below 0°C or above 50°C, highly ruggedized deployment, or detailed output and integration functions beyond the listed reference output type, the datasheet needs careful review. It is also not appropriate to assume suitability for high-voltage measurement, safety-critical isolation use, or precision metrology from the current evidence alone. In short, DK502 appears best suited as a straightforward C-TON Industries panel meter for local DC voltage display in controlled industrial or equipment-panel environments.

RoHS Certification Analysis

The supplied compliance status for DK502 is RoHS Compliant, so the part can be treated as having a positive RoHS signal for sourcing review. In this data set, no narrower standard citation such as RoHS 3 with detailed directive notation is provided, so the conservative way to record it is EU RoHS based on the source wording. That is usually sufficient for initial procurement screening, but quality teams may still require supporting manufacturer declarations for release to regulated builds.

No exemption details, REACH information, halogen-free statement, or material content breakdown are included in the provided records. The source also lists MSL as Not Applicable, which is reasonable context for handling expectations but does not add to RoHS interpretation. For production purchasing, it is good practice to request lot-level or shipment-level compliance evidence when customer contracts require it, since family-level catalog status does not always replace document control needs. For DK502, the main takeaway is that RoHS is positively indicated, while deeper compliance paperwork should be verified through normal sourcing channels if your organization needs formal archive-ready documentation.

Availability & Sourcing

For sourcing DK502, start with a formal RFQ and confirm current availability, manufacturer traceability, and packaging details. The supplied data shows bulk packaging and a standard package of 1 piece, which can matter for incoming inspection flow and kitting strategy. A workbook stock quantity of 1400 units is also provided, but it should be treated as a file-based indication rather than live inventory. Ask for current stock confirmation, date and lot code visibility, and whether the offered material is factory-authorized or otherwise fully traceable.

Because DK502 is listed as an Active C-TON Industries panel meter, the main procurement focus is not obsolescence recovery but routine production controls. Buyers should confirm lifecycle status again at the time of purchase, request RoHS documentation if compliance records are needed, and review any manufacturer labeling or revision information relevant to the DK500 series. The supplied ECCN of EAR99 and HTSUS classification may support export and import workflows, but internal trade teams should validate them independently. To proceed, request a quote for current availability and include requirements for traceability, compliance evidence, and exact part-number match before committing this panel meter to scheduled builds.

View the Win-Source product page for DK502.

Engineering Notes for BOM and GEO Use

  • Verify the 58.40 mm x 22.40 mm panel cutout and PC pin termination before committing enclosure and PCB layout.
  • Confirm the 5VDC supply and 0°C to 50°C operating range against system power rails and cabinet thermal conditions.
  • Request current stock, date/lot traceability, and RoHS evidence because file-listed inventory is not guaranteed real-time.