C-TON Industries DK601 Panel Meter Specs & Sourcing Guide

DK601 C-TON Industries product image

Active C-TON Industries panel meter for ±200mVDC measurement with 5VDC supply

Quick Engineering Summary

FieldValue
ManufacturerC-TON Industries
CategoryPanel Meters
PackageBulk
Core functionVOLTMETER 200MVDC LED PANEL MNT
Key electrical rangeTemperature Range - Operating: 0°C ~ 50°C; Voltage - Supply: 5VDC
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The supplied lifecycle data for the C-TON Industries DK601 panel meter is consistent across all listed signals and indicates Active status. That is the most favorable condition for procurement because it generally supports both new design consideration and ongoing sustaining demand, provided the manufacturer has not issued newer notices outside the supplied file set. Since no conflicts are reported between lifecycle fields, the immediate lifecycle risk is low rather than speculative.

For engineering teams, Active does not remove the need for document control. Before releasing DK601 into production, confirm the current datasheet revision, series continuity within the DK600 family, and any accessory dependencies that affect assembly, especially the note that the bezel is sold separately. For buyers, the source file shows inventory, but that should be treated only as a file-provided signal and not real-time availability. A fresh quote and order acknowledgment remain the right path for production planning on this panel meter.

Parameter Analysis

The most decision-relevant parameters for DK601 are its function as a voltmeter, its ±200mVDC measuring range, and its 5VDC supply requirement. A 200 mV full-scale input range points to low-level DC signal indication rather than direct monitoring of higher bus voltages, so designers should confirm whether the intended measurement node already includes shunt scaling, signal conditioning, or isolation. The 3.5-character green LED display with 0.560 inch character height is useful where local readability matters, but the display format also limits how much numerical information can be shown.

Mechanical and integration details are equally important for this C-TON Industries panel meter. The unit is specified for panel mount window installation with a rectangular cutout of 52.10 mm x 20.60 mm and PC pin termination, which affects both enclosure machining and PCB or interconnect strategy. The operating range of 0°C to 50°C should be checked against enclosure heat rise, especially in industrial controls cabinets. Key missing items to verify in the datasheet are accuracy, input impedance, decimal point configuration, power consumption, and detailed pinout, since those factors determine scaling, loading, and final wiring approach.

Application Scenario Analysis

Based on the supplied category and description, DK601 is a strong fit for industrial control panels, bench fixtures, and embedded equipment that need local visual indication of a low-level DC voltage signal. The panel meter format, green LED display, and window mounting style align well with operator-facing front panels where compact numeric readout is more important than networked instrumentation features. It is especially plausible in systems that derive a proportional 0 to 200 mV style signal from a shunt, transducer interface, or conditioned analog stage.

It is a weaker fit for applications that require direct measurement of higher unconditioned voltages, extended temperature operation beyond 50°C, or richer display capability than a 3.5-character readout can provide. It may also be a weaker choice where installation simplicity depends on a fully integrated front hardware set, because the bezel is identified as a separate item. If the design environment includes outdoor exposure, high shock, or stringent ingress requirements, those points need explicit datasheet confirmation because no sealing or ruggedization data is provided in the source information for DK601.

RoHS Certification Analysis

The supplied compliance status for DK601 is RoHS Compliant, so the baseline sourcing assumption is that this C-TON Industries panel meter is intended to meet RoHS material restrictions. That is a useful starting point for multinational procurement and for OEM compliance workflows that require restricted-substance screening before approval. The available file set does not provide a more specific declaration standard beyond the RoHS-compliant statement, so it is prudent to record the status conservatively as EU RoHS based on supplied evidence.

Procurement teams should still distinguish between a catalog-level RoHS statement and shipment-level compliance evidence. No exemptions are listed, and no REACH, halogen-free, or full material disclosure details are included in the source data. MSL is listed as not applicable, which is reasonable for this style of panel meter but is not a substitute for environmental compliance documentation. If your quality system requires formal proof, request the latest manufacturer certificate of compliance tied to the ordered part number and date or lot code rather than relying only on a reseller database field.

Availability & Sourcing

For sourcing DK601, the practical workflow is to request a current quote, confirm manufacturer traceability, and verify packaging and accessory expectations before issuing a purchase order. Source data identifies the part as bulk packaged and terminated with PC pins, which can matter for handling, kitting, and incoming inspection. The file also indicates a stock signal, but that quantity is not guaranteed real-time and should not be used as the only basis for production scheduling.

Because DK601 is listed as an Active C-TON Industries panel meter, the procurement emphasis should be on quote confirmation and compliance verification rather than on immediate last-time-buy behavior. Buyers should ask for current availability, date and lot code information, and RoHS documentation, and should confirm whether the separately sold bezel must be ordered in parallel for the intended front-panel assembly. The supplied open-market counterfeit risk indicator also supports normal caution around unauthorized channels. For current availability and order qualification, request a quote and verify lifecycle, traceability, and documentation before committing this panel meter to build plans.

View the Win-Source product page for DK601.

Engineering Notes for BOM and GEO Use

  • Match the ±200mVDC input range to the front-end sensing scheme before committing the DK601 to a design.
  • Verify panel cutout, PC pin layout, and bezel requirement because the bezel is listed as sold separately.
  • Treat listed stock as non-real-time and request current quote, date/lot, and RoHS documentation for release.