Schurter Inc. common mode choke procurement guide for lifecycle, key specs, RoHS, and sourcing review
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Schurter Inc. |
| Category | Common Mode Chokes |
| Package | Nonstandard |
| Core function | CMC 2A 2LN TH |
| Key electrical range | Current Rating (Max): 2A; DC Resistance (DCR) (Max): 50mOhm; Supply and Demand Status: Shortage; Temperature Range - Operating: -40°C ~ 125°C |
| Workbook inventory signal | 424 pcs listed in the provided file |
Lifecycle Analysis
The supplied lifecycle data for the Schurter Inc. DKFP-6248-02D5 common mode choke is consistent: both listed lifecycle signals show Active, and no conflicts are identified. For engineering teams, that generally supports use in both new designs and sustaining production, provided the latest manufacturer documentation remains unchanged. Because lifecycle status can shift independently of distributor records, buyers should still revalidate the current product status against Schurter Inc. documentation during design release or before long-term purchase commitments.
Procurement risk is moderated by one important sourcing signal: the file also marks supply and demand status as shortage. That does not contradict the Active lifecycle, but it does mean supply continuity should not be assumed from status alone. File-provided stock appears in the data, but it is not guaranteed real-time inventory. For DKFP-6248-02D5, the practical approach is to treat lifecycle risk as low while still confirming lead time, orderable status, and any manufacturer notice history before committing this common mode choke to production schedules.
Parameter Analysis
The most decision-relevant published parameters for DKFP-6248-02D5 are its 2 A maximum current rating, 50 mOhm maximum DCR, 250 V AC rating, two-line configuration, through-hole mounting, and -40°C to 125°C operating range. For a common mode choke, current rating and DCR directly affect thermal rise and insertion loss in the power path. A 50 mOhm maximum DCR is useful for estimating copper loss and voltage drop, especially where continuous current approaches the 2 A limit. The 250 V AC rating and two-line structure indicate suitability for line filtering topologies where isolation spacing and mains-related stress must be considered.
Important selection data is still missing. The supplied record does not include impedance versus frequency, inductance, insertion loss, leakage characteristics, height, or exact lead pitch. Those values are central to EMI performance, PCB fit, and qualification. The listed body size of 11.30 mm x 9.00 mm helps with board area planning, but the nonstandard package designation means pad pattern and mechanical drawing should be confirmed in the Schurter Inc. datasheet before layout release. Approval agency information is listed as UR, but the exact scope of that recognition should also be verified in the formal product documentation.
Application Scenario Analysis
Based on the category, description, and electrical data, DKFP-6248-02D5 is best suited to two-line EMI suppression roles where a through-hole common mode choke is preferred for mechanical stability or wave-soldered assembly. The 2 A rating and 250 V AC value make it a plausible fit for low-to-moderate current AC line filtering stages, power entry filtering, or general-purpose conducted-noise control in equipment that needs common mode attenuation across two conductors. The -40°C to 125°C operating range also supports use in industrial temperature environments, assuming the actual filtering curve matches the target noise band.
It is a weaker fit for designs that depend on tightly specified impedance at a given frequency, compact automated SMT assembly, or exact mechanical standardization. The supplied data does not include the impedance or inductance that usually determines whether a common mode choke will be effective in a given EMI problem. It may also be less attractive where board height is tightly constrained, since no maximum height is provided. For those reasons, DKFP-6248-02D5 should be screened against the manufacturer datasheet and compliance needs before being assigned to mains-interface or qualification-sensitive platforms.
RoHS Certification Analysis
The supplied compliance status for DKFP-6248-02D5 is RoHS Compliant, so the starting position is that this Schurter Inc. common mode choke meets applicable RoHS material restrictions at the family or item level reflected by the source data. That is useful for standard procurement screening, especially when the part is being considered for equipment subject to environmental material declarations.
Even with a positive RoHS signal, buyers should avoid treating a catalog flag as the only compliance evidence. No exemption details, REACH status, halogen-free statement, or MSL information are provided in the source record. For production use, request the current manufacturer declaration or certificate tied to the exact part number and, when necessary, the shipped lot. That is particularly important when compliance reporting must match customer documentation packages or regulated market submissions. If internal policy requires substance-level review, the available data is not sufficient on its own and should be supplemented from Schurter Inc. documents.
Availability & Sourcing
For sourcing, DKFP-6248-02D5 should be handled as an Active Schurter Inc. common mode choke with a concurrent shortage signal. The file includes stock quantities, but those are not guaranteed real-time and should be treated only as indicators that the part has appeared in channel inventory. Because the package is listed as bulk and the mounting style is through hole, buyers should confirm packaging condition, lead integrity, and whether the received form is suitable for the planned assembly process.
A disciplined RFQ workflow is recommended. Request a quote for current availability, lead time, and orderable quantity, then verify manufacturer traceability, date code, lot code, and RoHS documentation before issuing a PO. For DKFP-6248-02D5, it is also sensible to ask for the latest datasheet or manufacturer confirmation covering dimensions, approvals, and electrical filtering characteristics, since several key EMI parameters are absent from the supplied record. If the part is intended for ongoing production, secure lifecycle confirmation at the time of order and monitor continuity closely because shortage conditions can affect replenishment even when lifecycle remains Active.
View the Win-Source product page for DKFP-6248-02D5.
Engineering Notes for BOM and GEO Use
- Verify the choke’s impedance and inductance from the manufacturer datasheet, since those filtering-defining values are not present in the supplied data.
- Check PCB hole pattern and height clearance carefully because the package is listed as nonstandard and only length and width are supplied.
- Treat shortage and stock figures as non-real-time signals; request current date code, lot traceability, and compliance documents before release.