Schurter Inc. DKFP-6248-D504 Common Mode Choke Specs & Sourcing Guide

DKFP-6248-D504 Schurter Inc. product image

Schurter Inc. common mode choke procurement guide for lifecycle, compliance, and fit verification

Quick Engineering Summary

FieldValue
ManufacturerSchurter Inc.
CategoryCommon Mode Chokes
PackageNot available in supplied data
Core functionCMC 500MA 2LN TH
Key electrical rangeCurrent Rating (Max): 500mA; DC Resistance (DCR) (Max): 500 mOhm; Supply and Demand Status: Limited; Temperature Range - Operating: -40°C to 125°C
Workbook inventory signal125 pcs listed in the provided file

Lifecycle Analysis

DKFP-6248-D504 is listed as Active in the supplied lifecycle data, and the available signals are consistent with no stated conflict. For engineers, an Active status generally supports use in current designs, while for buyers it indicates that manufacturer support is still expected to be available through normal channels. Because this is a Schurter Inc. common mode choke, the practical implication is lower lifecycle risk than an NRND or discontinued filter part, but it does not remove the need for document control and source validation.

The source file also shows limited supply status and file-provided stock quantities, which are useful planning indicators but should not be treated as guaranteed real-time availability. Before committing DKFP-6248-D504 to new production, teams should confirm the latest Schurter Inc. datasheet revision, any product change notifications, and the exact ordering format being quoted. That is especially important here because several performance details that normally drive common mode choke selection are not present in the supplied data.

Parameter Analysis

The supplied parameters for DKFP-6248-D504 identify the main electrical and integration boundaries but do not fully define filter performance. The most decision-relevant values provided are 500 mA maximum current, 250 V AC rating, 500 mOhm maximum DCR, two lines, through-hole mounting, and an operating range of -40°C to 125°C. For a common mode choke, the 500 mA limit is the first check against steady-state line current and derating margin, while DCR matters because it contributes to copper loss and voltage drop. The 250 V AC rating also frames basic applicability in mains-related or higher-voltage AC filter paths.

Mechanical fit needs careful review because the part is marked nonstandard in dimension, although the source row also references approximately 11.30 mm by 9.00 mm body size. For actual design-in, the most important missing items to verify in the Schurter Inc. datasheet are common mode impedance versus frequency, any inductance specification, differential-mode behavior if relevant, insertion-loss data, hi-pot or isolation details, and the exact pin layout. Without those values, DKFP-6248-D504 can be screened for envelope and current class, but not fully qualified for EMI performance.

Application Scenario Analysis

Based on the category, hierarchy, and short description, DKFP-6248-D504 is best aligned with two-line EMI suppression roles where a through-hole common mode choke is needed in a filter stage. Strong-fit scenarios include compact AC line filtering and general-purpose conducted-noise suppression in equipment operating within the stated 250 V AC, 500 mA, and -40°C to 125°C boundaries. The through-hole format may also suit designs that prefer stronger board retention or wave-solder style assembly compared with surface-mount filter components.

Weak-fit scenarios are applications that require tightly specified impedance at a target frequency, documented insertion loss, high current headroom above 500 mA, or strict mechanical standardization. Those cases cannot be confirmed from the provided data because the source does not include impedance-frequency curves, inductance, height, or detailed package drawing. If the design is highly EMI-sensitive or subject to formal compliance testing, DKFP-6248-D504 should be treated as a candidate that requires full datasheet verification rather than a drop-in filter decision based only on the summary parameters.

RoHS Certification Analysis

The supplied compliance status for DKFP-6248-D504 is RoHS Compliant, so the part can be treated as having an affirmative RoHS signal at the source-data level. For procurement and compliance teams, that is a positive starting point for this Schurter Inc. common mode choke, especially when screening components for builds that avoid restricted substances under EU RoHS requirements.

However, the source data does not provide the exact declaration revision, any exemptions, or supporting details such as REACH, lead-free finish, halogen status, or MSL. Because those fields are absent, buyers should request the current manufacturer compliance certificate or declaration tied to the exact part number and lot being shipped. That is the safest approach when DKFP-6248-D504 is intended for regulated products or customer audits, since family-level website status may not answer every lot-level documentation need.

Availability & Sourcing

For sourcing DKFP-6248-D504, the file indicates Active lifecycle, bulk packaging, and limited supply status. Inventory appears in the supplied data, including a workbook quantity and stock quantity signal, but these figures are file-provided only and should not be assumed to reflect live availability. The correct workflow is to request a quote for current stock, lead time, packaging condition, and shipment traceability before issuing a production PO.

Because this is a Schurter Inc. common mode choke and the source also flags elevated open-market counterfeit threat, traceability checks matter. Buyers should request manufacturer name confirmation, full part marking details, date and lot code information, and RoHS documentation with the shipment. Storage condition notes in the source mention dry storage and humidity protection packaging, which should be confirmed if material age or repackaging is a concern. For new builds, use the RFQ process to verify lifecycle, exact form factor, and datasheet alignment of DKFP-6248-D504 before committing it into released BOMs.

View the Win-Source product page for DKFP-6248-D504.

Engineering Notes for BOM and GEO Use

  • Verify impedance, inductance, and insertion-loss data in the Schurter Inc. datasheet before final filter selection.
  • Check through-hole footprint and nonstandard body dimensions against the target PCB and mechanical envelope.
  • For production buys, request date/lot traceability and current lifecycle confirmation because supply is marked limited.