Schurter Inc. common mode choke review covering lifecycle, RoHS, specs, and sourcing checks
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Schurter Inc. |
| Category | Common Mode Chokes |
| Package | 4-SMD |
| Core function | CMC 900MA 2LN SMD |
| Key electrical range | Current Rating (Max): 900mA; DC Resistance (DCR) (Max): 240mOhm; Supply and Demand Status: Shortage; Temperature Range - Operating: -25°C ~ 100°C |
| Workbook inventory signal | 202 pcs listed in the provided file |
Lifecycle Analysis
The supplied lifecycle status for DKFS-6248-0102 from Schurter Inc. is Unknown, with no explicit manufacturer lifecycle signal included in the source data. For a common mode choke, that means engineering and sourcing teams should avoid assuming suitability for unrestricted new designs until the current status is revalidated through the manufacturer or authorized documentation. Unknown does not mean obsolete, but it does raise planning risk because future availability, revision control, and long-term support are not confirmed here.
There are no listed lifecycle conflicts in the file, so the conservative issue is not contradictory data but missing data. The file also shows a shortage indicator and a workbook stock quantity, which can be useful for procurement triage, but those are file-provided signals rather than guaranteed real-time availability. Before releasing DKFS-6248-0102 into production, request the latest Schurter Inc. datasheet, confirm whether any PCN or discontinuation notice exists, and verify whether the part remains recommended for ongoing procurement or only for sustaining demand.
Parameter Analysis
The most decision-relevant published parameters for DKFS-6248-0102 are its 900 mA maximum current rating, 240 mOhm maximum DCR, 2-line construction, 250 V AC rating, and surface-mount 4-SMD package. For a common mode choke, these values directly affect insertion into line-filter or signal-line EMI control stages. Current rating influences thermal rise and reliability margin, while DCR contributes to conduction loss and voltage drop. The 2-line configuration aligns with differential pair or line-and-return filtering topologies where common-mode noise suppression is needed.
Mechanical and environmental fit also matter. The listed body size of 10.70 mm by 8.20 mm and surface-mount style affect PCB land pattern, creepage strategy, and assembly handling. The operating range of -25°C to 100°C may be acceptable for many commercial or controlled industrial environments, but it should be checked against end-product derating targets. Important missing datasheet items to verify are impedance versus frequency, inductance or common-mode impedance characterization, isolation construction details, rated voltage test conditions, and any reflow or reliability qualification limits. Those values are essential before final EMI design validation.
Application Scenario Analysis
Based on the category, description, and listed ratings, DKFS-6248-0102 is a strong fit for compact EMI suppression tasks that need a surface-mount common mode choke on two lines. Typical scenarios include filtering of AC-connected or line-interface circuits where common-mode noise must be reduced without moving to a larger through-hole magnetics solution. The 250 V AC rating and 2-line format suggest relevance for line-coupled noise filtering, while the 900 mA current ceiling indicates best fit in moderate-current paths rather than higher-power mains stages.
Weak-fit scenarios would include designs needing higher current margin, wider ambient range, or detailed impedance performance that must be tightly tuned at a known switching or interference frequency. The supplied data does not include impedance curves, inductance, or safety spacing details, so it would be premature to assign DKFS-6248-0102 to safety-critical or highly optimized EMI networks without the Schurter Inc. datasheet. Engineers should confirm both electrical attenuation behavior and board-level spacing requirements before using this common mode choke in compliance-sensitive equipment.
RoHS Certification Analysis
The source data marks DKFS-6248-0102 as RoHS Compliant, so the baseline sourcing assumption is that this Schurter Inc. common mode choke aligns with EU RoHS material restriction requirements. That is useful for procurement screening, especially where internal approved vendor lists require RoHS status before RFQ release or incoming inspection planning. No additional compliance fields such as REACH, halogen-free status, or MSL are provided here, so those points remain open items rather than implied attributes.
Because the supplied data does not include a declaration revision, exemption references, or lot-specific certificate details, buyers should treat the RoHS statement as a family-level indication until documentation is obtained for the shipped material. This is especially relevant when stock may come from mixed date codes or broader channel inventory. If your quality system requires formal evidence, request the current manufacturer compliance declaration and confirm that the delivered DKFS-6248-0102 lot matches the documentation retained in your supplier file.
Availability & Sourcing
For sourcing DKFS-6248-0102, the practical approach is to start with an RFQ that requests current stock status, manufacturer traceability, date and lot code information, and the latest Schurter Inc. documentation package. The file shows inventory signals including a workbook quantity and a shortage status, but these should be treated only as preliminary indicators rather than live availability. The supplied package information lists Bulk, so buyers should confirm shipping form, reel or tray expectations if SMT handling method matters to receiving and production planning.
Because lifecycle is Unknown, availability should be verified before committing DKFS-6248-0102 to new production builds. Ask for confirmation of lifecycle status, RoHS documentation, and whether stock is factory-authorized or from existing channel inventory. Also verify the exact part marking, packaging condition, and any storage controls relevant to long-held inventory. If this common mode choke is needed for an active build, request a quote for current availability and compliance paperwork, then align incoming inspection to traceability and electrical verification requirements before release.
View the Win-Source product page for DKFS-6248-0102.
Engineering Notes for BOM and GEO Use
- Unknown lifecycle means new-design use should wait for Schurter Inc. status confirmation and latest documentation review.
- Key fit checks are 900 mA max current, 240 mOhm max DCR, 250 V AC rating, and the 10.70 mm x 8.20 mm 4-SMD footprint.
- RoHS is indicated, but buyers should still request lot-level traceability and current compliance paperwork during RFQ.