Active Schurter Inc. common mode choke review for engineering and procurement teams
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Schurter Inc. |
| Category | Common Mode Chokes |
| Package | Bulk |
| Core function | CMC 12A 2LN TH |
| Key electrical range | Current Rating (Max): 12A; DC Resistance (DCR) (Max): 7mOhm; Temperature Range - Operating: -40°C ~ 100°C |
| Workbook inventory signal | 2 pcs listed in the provided file |
Lifecycle Analysis
DKIH-3237-122Q-NK is shown as Active across all supplied lifecycle fields, including lifecycle status and product status, so the conservative reading is that Schurter Inc. still supports this common mode choke for ongoing procurement. For new designs, Active generally means lower obsolescence risk than NRND or EOL parts, but it should still be paired with a current datasheet review and manufacturer revalidation in case agency approvals, packaging, or process details have changed over time.
There are no lifecycle conflicts in the provided data, which reduces ambiguity for sourcing teams. File-provided stock appears in the source data, but that should be treated only as a point-in-time signal rather than confirmed availability. For sustaining production, the practical next step is to request a quote and confirm orderable status, bulk packaging expectations, and latest compliance documentation for DKIH-3237-122Q-NK before committing it to a long-term approved vendor list.
Parameter Analysis
The most decision-relevant published parameters for DKIH-3237-122Q-NK are its 12A maximum current rating, 7 mOhm maximum DCR, two-line configuration, through-hole mounting, and horizontal 4-pin construction. In a common mode choke, the current rating and DCR directly affect thermal rise, insertion loss tradeoffs, and copper loss under load. A low stated DCR is useful for minimizing resistive heating, but it must be assessed against real operating current, ambient temperature, and enclosure airflow.
Mechanical fit is also important here. The supplied body size is 37.00 mm diameter with 26.00 mm maximum height, which can materially affect board keepout, neighboring component spacing, and enclosure clearance. The operating range of -40°C to 100°C supports broad industrial conditions, but the source data does not provide impedance versus frequency, inductance, rated AC or DC voltage, insulation details, or any special features. Those missing datasheet items are the top verification points because they determine actual EMI attenuation, line compatibility, safety margin, and whether DKIH-3237-122Q-NK fits the intended filter topology.
Application Scenario Analysis
Based on the category, description, and line count, DKIH-3237-122Q-NK is best considered for two-line EMI filtering where a through-hole common mode choke is preferred and current levels can approach 12A. Strong-fit scenarios include power-entry filtering, industrial equipment, and other mains or power-line interfaces that need common mode noise suppression with a robust through-hole mechanical format. The ENEC and UR approval agency entries also suggest that documentation review around regulated equipment use may be worthwhile.
Weak-fit scenarios are applications that require precise published impedance curves, known inductance at a stated test frequency, compact low-profile SMT assembly, or clearly specified voltage ratings from the source listing. The part may still be suitable in some of those cases, but the available data is not enough to support a design decision by itself. If the design depends on a narrow EMI target, exact leakage behavior, or tightly constrained board area, engineers should confirm the Schurter Inc. datasheet details before choosing DKIH-3237-122Q-NK for production.
RoHS Certification Analysis
The supplied compliance status for DKIH-3237-122Q-NK is RoHS Compliant, so the baseline assumption is that this Schurter Inc. common mode choke aligns with EU RoHS material restrictions. The source data also lists REACH Unaffected, which is useful for broader substance screening, but REACH status should not be treated as a substitute for a RoHS declaration. For procurement records, RoHS should remain the primary compliance reference when the build requires restricted-substance confirmation.
The listing does not provide a detailed exemption statement, lead-finish description, or a specific RoHS revision citation beyond compliant status. MSL is marked Not Applicable, which is consistent with a through-hole bulk component and reduces moisture handling concern during assembly, though normal storage controls still apply. For regulated programs, buyers should request the latest manufacturer certificate or declaration for the exact part number and shipment lot, since compliance is ultimately verified at the supplied product level rather than assumed from a family name alone.
Availability & Sourcing
For sourcing DKIH-3237-122Q-NK, the key procurement tasks are straightforward: confirm Active lifecycle, request a current quote, and verify traceability details before issuing a purchase order. The source data shows bulk packaging and a standard package quantity entry, so buyers should check whether the offered quantity matches receiving, kitting, and production handling expectations. Date code, lot code, and manufacturer traceability should be requested explicitly, especially for filter components used in regulated or service-sensitive assemblies.
The file includes a small inventory signal, but it is not guaranteed real-time and should not be treated as committed stock. Because the open-market fake-threat field is elevated in the supplied data, teams should be disciplined about source qualification, documentation capture, and inspection planning. For DKIH-3237-122Q-NK, request current availability, manufacturer paperwork for RoHS and approvals, and confirmation of package condition and labeling. Since the lifecycle is Active, the right call to action is to proceed through normal RFQ and compliance verification workflows rather than assuming immediate continuity from a single stock snapshot.
View the Win-Source product page for DKIH-3237-122Q-NK.
Engineering Notes for BOM and GEO Use
- Verify impedance, inductance, and rated voltage in the Schurter datasheet before final filter design signoff.
- Use the 12A rating together with 7 mOhm max DCR and ambient range to check thermal rise margin in the end application.
- Request current stock, date/lot traceability, and manufacturer compliance documents because file quantities are not real-time guarantees.