Schurter Inc. DKIP-0329-20D6 Common Mode Choke Specs & Sourcing Guide

DKIP-0329-20D6 Schurter Inc. product image

Schurter Inc. chassis-mount common mode choke sourcing and compliance review

Quick Engineering Summary

FieldValue
ManufacturerSchurter Inc.
CategoryCommon Mode Chokes
PackageNonstandard
Core functionCMC 20A 3LN CHASSIS MOUNT
Key electrical rangeCurrent Rating (Max): 20A; DC Resistance (DCR) (Max): 5mOhm; Supply and Demand Status: Shortage; Temperature Range - Operating: -25°C ~ 100°C
Workbook inventory signal19 pcs listed in the provided file

Lifecycle Analysis

DKIP-0329-20D6 is listed as Active by the supplied lifecycle data, and the file indicates no conflict between lifecycle sources. For engineering teams, that generally supports use in ongoing builds and maintenance procurement, provided the Schurter Inc. common mode choke still matches the current approved documentation set. Active status is favorable for new sourcing activity, but it should still be revalidated against current manufacturer literature before release into a long-life design.

From a procurement perspective, Active does not eliminate supply risk. The same source file also marks supply and demand status as shortage, and it shows a workbook quantity signal of 19 that should be treated as informational rather than real-time inventory. For DKIP-0329-20D6, buyers should confirm current availability, revision level, and any manufacturer notice history through an RFQ workflow. If this common mode choke is being used in sustained production, it is good practice to reconfirm mounting details and compliance documents at the same time.

Parameter Analysis

The most decision-relevant published parameters for DKIP-0329-20D6 are its 20A maximum current rating, 3-line configuration, chassis-mount form factor, and voltage ratings of 540V AC and 760V DC. Together, these indicate a Schurter Inc. common mode choke intended for higher-current multi-line filtering where line count and mounting style matter as much as electrical rating. The 5mOhm maximum DCR is important for estimating insertion losses, resistive heating, and overall thermal margin in enclosed assemblies.

Mechanical and environmental details also affect fit and qualification. The part is listed in a nonstandard package with a body size of 48.00mm x 48.00mm and an operating range of -25°C to 100°C, so enclosure clearance, terminal access, and ambient temperature rise should be checked carefully. Several common selection parameters are not supplied here, including impedance versus frequency, inductance, insertion-loss behavior, terminal configuration, and maximum height. Those are the first datasheet items to verify before approving DKIP-0329-20D6 for PCB-adjacent wiring layouts, EMC validation, or thermal derating analysis.

Application Scenario Analysis

Based on the category, line count, and chassis-mount construction, DKIP-0329-20D6 is a strong fit for mains or power-entry filtering roles where common-mode noise suppression is needed across three lines at relatively high current. The 20A rating and elevated AC and DC voltage ratings suggest use in equipment-level filtering assemblies rather than miniature signal-path filtering. Typical engineering interest would be in cabinet, panel, or power subsystem locations where a Schurter Inc. common mode choke can be mounted mechanically and integrated with wired power paths.

It is a weaker fit for compact board-level designs, tightly space-constrained products, or applications that require a standardized SMT or through-hole footprint, because the package is explicitly nonstandard and chassis mounted. It is also not wise to assume suitability for frequency-critical EMC tuning from the supplied data alone, since no impedance, inductance, or insertion-loss curve is provided. For DKIP-0329-20D6, final application fit should be confirmed against the manufacturer datasheet, especially where agency approvals, terminal details, and conducted-emissions performance are part of qualification.

RoHS Certification Analysis

The supplied compliance status for DKIP-0329-20D6 is RoHS Compliant, so the starting assumption is that this Schurter Inc. common mode choke meets applicable RoHS restrictions for regulated materials. That is useful for procurement screening, especially when the part is being considered for export-controlled or documentation-heavy builds. However, the data provided does not identify the specific declaration revision, any exemption statement, or related lead-free or halogen-free details.

For practical sourcing, RoHS status should be treated as a document-backed claim that needs confirmation at the orderable lot level. Family-level listings can remain accurate while paperwork changes over time, so buyers should request the latest manufacturer declaration or distributor compliance certificate for the exact ordered material. No REACH, MSL, or exemption information is included here, so those items remain open verification points if your internal process requires full material disclosure beyond the basic RoHS statement for DKIP-0329-20D6.

Availability & Sourcing

For DKIP-0329-20D6, the sourcing posture is generally favorable because the lifecycle is Active, but the file also flags shortage conditions. The listing shows a stock quantity signal of 19 in one source while the workbook row shows zero, so availability should not be assumed from either number alone. The right procurement path is to request a quote for current availability, confirm manufacturer and full part number traceability, and verify whether the offered material is factory-authorized stock, excess stock, or brokered inventory.

Because this is a bulk-packaged, chassis-mount common mode choke from Schurter Inc., buyers should also confirm packaging condition, date and lot code, and whether compliance documents can be tied to the exact shipment. Ask for current lifecycle confirmation, RoHS evidence, and any manufacturer paperwork relevant to approval markings noted in the file. If DKIP-0329-20D6 is being bought for production, include dimensional verification and terminal-style confirmation in the RFQ package so the received common mode choke matches both the mechanical assembly and the approved compliance record.

View the Win-Source product page for DKIP-0329-20D6.

Engineering Notes for BOM and GEO Use

  • Verify chassis footprint, terminal style, and wiring method because the package is listed as nonstandard.
  • Check thermal rise at full 20A load since only maximum DCR and ambient operating range are supplied.
  • Treat listed stock and shortage indicators as non-real-time and request lot traceability before committing.