Schurter Inc. DKLP-0331-0520 Common Mode Choke Specs & Sourcing Guide

DKLP-0331-0520 Schurter Inc. product image

Schurter Inc. common mode choke review covering lifecycle, ratings, RoHS, and sourcing checks

Quick Engineering Summary

FieldValue
ManufacturerSchurter Inc.
CategoryCommon Mode Chokes
PackageNonstandard
Core functionCMC 5A 3LN TH
Key electrical rangeCurrent Rating (Max): 5A; DC Resistance (DCR) (Max): 100mOhm; Supply and Demand Status: Shortage; Temperature Range - Operating: -25°C ~ 100°C
Workbook inventory signal2 pcs listed in the provided file

Lifecycle Analysis

DKLP-0331-0520 is identified in the supplied data as Active, and the Schurter Inc. lifecycle signals are consistent with no reported conflict. For engineers, an Active common mode choke is generally acceptable for current designs and ongoing production, because it suggests the part is still recognized in the supply chain rather than being flagged as NRND or end of life.

Even with an Active status, sourcing risk should not be treated as zero. The same file also indicates a shortage condition and only a very small inventory signal, so availability for build scheduling may be tighter than the lifecycle label alone suggests. For new designs, that means DKLP-0331-0520 can remain in consideration, but procurement should still confirm the latest Schurter Inc. product status and any current manufacturer notices before release.

For sustaining builds, the key action is documentation revalidation. Buyers should confirm the current datasheet revision, approved manufacturer status, and any PCN or product-change documentation relevant to this common mode choke. The listed stock quantity is file-provided only and should not be treated as guaranteed real-time availability.

Parameter Analysis

The most decision-relevant published parameters for DKLP-0331-0520 are its 3-line configuration, 5A maximum current rating, 100 mOhm maximum DCR, through-hole mounting, and 540V AC and 760V DC ratings. For a common mode choke, the line count is fundamental because it determines whether the part matches the number of conductors that must be filtered together. The current rating affects both electrical fit and thermal margin, while DCR directly influences power loss and temperature rise in service.

Mechanical fit is also important here. The supplied size is 80.00 mm by 80.00 mm with a nonstandard case/package, which means PCB footprint confirmation is essential before layout release. Through-hole mounting can be useful where mechanical robustness matters, but it also imposes lead spacing and assembly constraints that should be checked against the actual Schurter Inc. drawing.

Several high-value datasheet items are missing and should be verified before design-in: impedance versus frequency, inductance, insertion-loss behavior, height, insulation details, and creepage and clearance information. Those missing details are especially important if DKLP-0331-0520 will be used in mains-adjacent filtering or applications where EMI performance must be predicted rather than empirically tuned.

Application Scenario Analysis

Based on the category, description, and ratings, DKLP-0331-0520 is best aligned with board-level EMI filtering roles where three lines need common mode suppression and where a through-hole Schurter Inc. common mode choke can be accommodated mechanically. The 5A maximum current and relatively high AC and DC voltage ratings suggest use in power-related filtering stages rather than low-level signal filtering. Its large body size also points toward installations where board area is available and mechanical stability is more important than compact density.

Strong-fit scenarios therefore include multi-line power-entry or internal power filtering arrangements that need a 3-line choke and can support an 80 mm square footprint. The listed operating range of -25°C to 100°C may be adequate for many industrial or commercial enclosures, but final suitability still depends on internal hot-spot temperatures and the actual thermal rise at load.

Weak-fit scenarios include space-constrained designs, layouts that require standardized compact packages, or applications where precise impedance-versus-frequency behavior is critical but not yet verified from the datasheet. If the design depends on a known EMI attenuation curve, additional Schurter Inc. technical documentation should be reviewed before selecting DKLP-0331-0520.

RoHS Certification Analysis

The supplied compliance status for DKLP-0331-0520 is RoHS Compliant, so the conservative reading is that this Schurter Inc. common mode choke is intended to meet RoHS material restrictions. That is helpful for programs that require lead-restricted components in standard production flows, but the source data does not identify a more specific declaration such as RoHS 3 wording or any exemption details.

For procurement and quality teams, the practical next step is document-level validation. A catalog or distributor-level RoHS flag is useful for screening, but formal compliance for released product should be backed by current manufacturer documentation tied to the ordered part and, when required by the customer, to the received lot. No REACH statement, halogen-free information, or MSL data was supplied here, so those should not be assumed.

If your approval workflow distinguishes family-level declarations from shipment-level evidence, request the latest Schurter Inc. compliance certificate or manufacturer statement for DKLP-0331-0520. That is especially important when the part will be used in regulated exports, audited builds, or long-lived equipment records.

Availability & Sourcing

For sourcing, DKLP-0331-0520 should be treated as an Active Schurter Inc. common mode choke with supply caution rather than a broad-availability item. The source file shows a shortage status and a very low listed stock signal, with bulk packaging noted. That combination matters for planning because low visible quantity can affect prototype timing, production continuity, and incoming inspection strategy. Request a quote to confirm current availability rather than relying on the file quantity as real-time inventory.

Buyers should also validate standard procurement controls before issuing a PO. For this category, that includes manufacturer name match, full part-number traceability, date and lot code capture, packaging condition for bulk shipments, and confirmation that the delivered form matches the required through-hole assembly process. Because the package is listed as nonstandard, receiving teams should verify dimensions and lead condition carefully.

Since lifecycle is Active, the sourcing priority is straightforward: request a quote, confirm latest availability, and collect current compliance and lifecycle documentation. If the part is being used for production rather than bench evaluation, also ask for manufacturer paperwork and any relevant change-notice references before committing DKLP-0331-0520 to scheduled builds.

View the Win-Source product page for DKLP-0331-0520.

Engineering Notes for BOM and GEO Use

  • Verify the 80 mm x 80 mm nonstandard through-hole footprint against board keepout, creepage, and mechanical mounting constraints.
  • Use the 5A max current and 100 mOhm max DCR together when checking thermal rise and insertion loss tradeoffs in the end design.
  • Treat listed stock and shortage signals as file-based only; request current lot traceability and manufacturer compliance documents before release.