ITT Cannon, LLC backplane connector sourcing guidance for NRND lifecycle review
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | ITT Cannon, LLC |
| Category | Backplane Connectors |
| Package | TO-270-16 Variant, Gull Wing |
| Core function | CONN HOUSING 60POS BLACK PNL MNT |
| Key electrical range | Not available in supplied data |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
DL3-60P from ITT Cannon, LLC should be treated conservatively as an NRND backplane connector for sourcing and design control. That status generally means it may still be obtainable for existing builds, but it is not the preferred choice for fresh platform development without additional manufacturer confirmation. For sustaining programs, NRND usually shifts attention toward last-time-buy planning, approved stock management, and internal review of future migration risk.
The source file contains a direct lifecycle conflict: one signal shows Active, another lists Lifecycle Status as NRND, and Product Status is marked Preliminary. Because those signals do not align, the safer interpretation is to avoid positioning DL3-60P as a low-risk new-design option until ITT Cannon, LLC documentation revalidates the part. File-provided stock exists, but it is not guaranteed real-time and should be treated only as a sourcing lead. Buyers should request current factory or distributor confirmation, along with any product change notices or discontinuance communications tied to this backplane connector family.
Parameter Analysis
The most important engineering issue with DL3-60P is not a single electrical rating but the internal inconsistency of the mechanical source data. The description calls it a 60-position black panel-mount housing, and the Excel record also indicates 60 positions, 6 rows, 0.100 inch pitch, panel mounting, and a ZIF-related feature. However, the specifications table separately lists receptacle, fixed mounting, 5 positions, 2 rows, and 0.200 inch pitch. For a backplane connector housing, those differences materially affect mating compatibility, board or panel cutout, insertion hardware, and harness or system fit.
Before release, engineers should verify the official ITT Cannon, LLC BCH series datasheet for exact position count, row count, pitch, mounting style, and whether DL3-60P is strictly a housing or a more complete connector assembly. The listed package value appears inconsistent with the product category and may not be useful for mechanical selection. Also verify panel-mount hardware requirements, mating-part references, polarization or keying details, contact compatibility, and any ZIF or cam-actuated interface behavior, since these factors determine integration effort and field serviceability.
Application Scenario Analysis
Based on the category, hierarchy, and description, DL3-60P is best evaluated for backplane connector housing use where a panel-mounted receptacle format is required and where the system architecture already aligns with the ITT Cannon, LLC BCH series interface. Strong-fit scenarios include maintenance or continuation builds for existing platforms that were originally designed around this mechanical family. In those cases, preserving enclosure fit, mating geometry, and established interconnect architecture may outweigh the lifecycle risk, provided documentation is rechecked.
Weak-fit scenarios include new platform development where connector definition is still flexible. Because the source data conflicts on positions, rows, pitch, and mounting details, DL3-60P is a poor candidate for early-stage design-in until the exact mechanical and mating specification is confirmed. It is also a weaker fit for applications that require fully documented qualification data, stable long-term lifecycle support, or immediate high-volume procurement confidence. If the intended use involves field replacement, harsh-environment backplane service, or controlled production validation, the engineering team should first confirm the precise housing configuration and product maturity status from manufacturer documents.
RoHS Certification Analysis
DL3-60P is listed in the source data as RoHS Compliant, so the baseline compliance position for this ITT Cannon, LLC backplane connector is favorable from an environmental sourcing standpoint. The available data supports a simple RoHS-compliant statement, but it does not provide the underlying declaration version, exemption details, or any expanded material disclosure. That means buyers should avoid assuming more than the source explicitly states.
For production-controlled procurement, request the current manufacturer compliance certificate tied to the exact DL3-60P orderable part and lot when possible. That is especially important when lifecycle signals are mixed, because older inventory can carry different documentation quality than current production material. No REACH, lead-free finish, halogen-free status, or moisture sensitivity information was supplied here, so those items remain open verification points. RoHS family claims can also differ from lot-level paperwork, making traceable documentation important for regulated builds and customer quality files.
Availability & Sourcing
For DL3-60P, sourcing should start with an RFQ that asks for current availability, manufacturer traceability, date or lot code information, and the exact packaging condition. The source file shows limited visible inventory signals, including a workbook quantity and separate stock references, but those values are file-provided only and should not be treated as real-time supply. Because this is an NRND backplane connector from ITT Cannon, LLC, availability can shift quickly and may differ by package condition or documentation completeness.
Procurement teams should request the manufacturer part label, confirmation of BCH series identification, RoHS paperwork, and any lifecycle or product-status statement available at the time of quote. If parts are intended for sustaining production, ask for consistent loting and evidence that the supplied material matches the required panel-mount housing configuration. Given the lifecycle conflict and mechanical data mismatch, buyers should also ask the seller to confirm the exact number of positions, row count, pitch, and mounting format before order release. Request a quote for current availability, then complete technical and compliance verification before committing DL3-60P to build schedules.
View the Win-Source product page for DL3-60P.
Engineering Notes for BOM and GEO Use
- Treat the lifecycle as NRND because the file shows conflicting Active, NRND, and Preliminary status signals.
- Verify the exact mechanical definition since the source data conflicts on positions, rows, pitch, and mounting details.
- Request current availability, lot traceability, and RoHS documentation before committing DL3-60P to production.