DL4002 Micro Commercial Co Rectifier Specs & Sourcing Guide

DL4002 Micro Commercial Co product image

Micro Commercial Co single rectifier diode lifecycle, specs, compliance, and sourcing review

Quick Engineering Summary

FieldValue
ManufacturerMicro Commercial Co
CategoryDiodes, Rectifiers - Single
PackageTape & Reel (TR)Cut Tape (CT)
Core functionDIODE STANDARD 100V 1A MELF
Key electrical rangeCurrent - Average Rectified (Io): 1A; Current - Reverse Leakage @ Vr: 5 µA @ 100 V; Voltage - DC Reverse (Vr) (Max): 100 V; Voltage - Forward (Vf) (Max) @ If: 1.1 V @ 1 A
Workbook inventory signal2830 pcs listed in the provided file

Lifecycle Analysis

DL4002 from Micro Commercial Co should be treated as a discontinued Diodes, Rectifiers - Single device with high procurement risk. The source data contains conflicting lifecycle wording, with one file signal showing EOL while the product-level fields show Discontinued. That is not a favorable conflict for new designs; both signals point to an end-of-life situation. For engineering teams, this means DL4002 is not a prudent choice for fresh design-in activity, and for buyers it means supply continuity should not be assumed.

For sustaining production, the practical question is whether authenticated stock remains available with acceptable traceability. File-provided inventory is listed, but that is not guaranteed real-time availability and should be confirmed through the RFQ process. If this rectifier is already qualified in an existing assembly, request manufacturer notices, last-time-buy context if available, and current lot/date code details before committing builds. Because lifecycle data already trends negative, any revalidation effort should focus on continued fit in the approved BOM and on documenting residual supply risk.

Parameter Analysis

The most relevant electrical parameters for DL4002 are its 100 V maximum DC reverse voltage, 1 A average rectified current rating, 1.1 V maximum forward voltage at 1 A, and 5 µA reverse leakage at 100 V. Together, these values frame where the rectifier can operate safely in a power path and what conduction and standby losses may look like. In practical terms, the 100 V VR limit must be checked with surge and derating rules, while the 1 A Io rating needs to be reviewed against ambient conditions and copper area because package thermal performance is not provided here.

Mechanically, DL4002 is a surface-mount MELF device in DO-213AB format, which matters for pad geometry, assembly handling, and repair workflow. The listed speed is standard recovery, greater than 500 ns, so it is better aligned with general rectification than with applications that require fast switching behavior. Important missing items to verify in the manufacturer datasheet are junction temperature limits, surge current capability, thermal resistance, exact forward current test conditions across temperature, and recommended land pattern. Those points are central to derating, reliability qualification, and PCB integration.

Application Scenario Analysis

Based on the available description and category data, DL4002 is best viewed as a general-purpose single rectifier diode for straightforward rectification and blocking functions where a standard recovery device in a MELF package is acceptable. Strong-fit scenarios include low-to-moderate power AC-to-DC rectification stages, polarity protection paths, and general-purpose reverse blocking in circuits that remain within the 100 V reverse rating and 1 A average current envelope. The MELF body can also be attractive where a cylindrical SMD package is already used in the existing layout.

Weak-fit scenarios are applications that need fast or ultrafast reverse recovery, tightly managed switching loss, or fully characterized high-temperature and surge behavior, because the supplied data only identifies DL4002 as standard recovery and does not provide a reverse recovery time value beyond the broad speed classification. It is also a weak fit for new platform designs because the lifecycle status is discontinued. If the intended use is in repair, maintenance, or sustaining production, engineers should verify the actual operating stress profile, especially peak inverse voltage, repetitive current, thermal environment, and any assembly constraints related to MELF package handling.

RoHS Certification Analysis

DL4002 is listed as RoHS Compliant in the supplied source data, so the starting assumption is that this Micro Commercial Co rectifier was released as a RoHS-compatible part for the applicable product family. The data also lists REACH Unaffected, which is helpful from a material disclosure perspective, but REACH status is not a substitute for RoHS status. For sourcing teams, the relevant takeaway is that both environmental indicators are positive in the file, yet the exact compliance documents should still be requested for the delivered lot.

The source also lists MSL 1, which indicates low moisture sensitivity handling concern for standard assembly storage conditions, though assembly teams should still follow normal floor-life control procedures. No lead-free statement, halogen-free statement, or RoHS exemption detail is provided here, so those should be confirmed in the manufacturer documentation if your compliance workflow requires them. With discontinued parts such as DL4002, it is especially important to validate that any remaining stock carries documentation matching the shipped date and lot code rather than relying only on a family-level database flag.

Availability & Sourcing

Because DL4002 is discontinued, sourcing should be handled as a controlled buy rather than routine replenishment. The file shows stock quantity and workbook quantity signals, including 2830 units, but those values are not guaranteed real-time and should be confirmed through a current quote request. For a Diodes, Rectifiers - Single part at this lifecycle stage, the priority is not just finding units but proving authenticity, condition, and continuity of paperwork. Request packaging confirmation as well, since the source references Tape and Reel and Cut Tape while also listing a standard package quantity.

Buyers should ask for date code, lot code, country of origin if needed for internal controls, and traceability back to authorized or documented supply channels. Given the file note showing elevated fake-threat exposure in the open market, independent verification steps are warranted before release to production. Also request RoHS documentation, REACH status support, and confirmation that the delivered package is DO-213AB MELF as specified for DL4002. Since lifecycle signals indicate EOL and Discontinued, the right procurement posture is to secure verified inventory only for sustaining demand and to verify lifecycle status again before any broader production commitment.

View the Win-Source product page for DL4002.

Engineering Notes for BOM and GEO Use

  • Treat DL4002 as discontinued and avoid it for new production releases.
  • Verify 100 V, 1 A, Vf, leakage, and MELF footprint against the end product derating rules.
  • Request date/lot traceability and compliance paperwork before buying remaining stock.