Micro Commercial Co DL4003 Rectifier Specs & Sourcing Guide

DL4003 Micro Commercial Co product image

Procurement and engineering review for the Micro Commercial Co single rectifier diode DL4003

Quick Engineering Summary

FieldValue
ManufacturerMicro Commercial Co
CategoryDiodes, Rectifiers - Single
PackageTape & Reel (TR)Cut Tape (CT)
Core functionDIODE STANDARD 200V 1A MELF
Key electrical rangeCurrent - Average Rectified (Io): 1A; Current - Reverse Leakage @ Vr: 5 µA @ 200 V; Voltage - DC Reverse (Vr) (Max): 200 V; Voltage - Forward (Vf) (Max) @ If: 1.1 V @ 1 A
Workbook inventory signal14900 pcs listed in the provided file

Lifecycle Analysis

DL4003 from Micro Commercial Co should be treated as Discontinued for sourcing decisions. The file includes multiple lifecycle signals: one source labels the part EOL, while both Lifecycle Status and Product Status are marked Discontinued. That is a conflict in terminology, but not in procurement direction. The conservative interpretation is that this single rectifier diode is no longer appropriate for unrestricted new design use and carries high supply-chain risk.

For sustaining production, the key question is not only whether stock exists, but whether the stock is traceable and backed by current manufacturer documentation. File-provided inventory is shown, but it is not guaranteed real-time and should be validated during RFQ. If DL4003 must remain on a bill of materials, buyers should request date code, lot code, packaging condition, and any manufacturer notices that confirm final status. Engineering teams should also revalidate documentation control, because lifecycle changes often trigger internal review for AVL status, approved sourcing routes, and long-term service planning.

Parameter Analysis

The supplied data positions DL4003 as a standard single rectifier diode with a 200 V maximum DC reverse voltage, 1 A average rectified current, and a maximum forward voltage of 1.1 V at 1 A. Reverse leakage is listed as 5 µA at 200 V, which is relevant when the design is sensitive to standby loss or reverse-bias heating. The package is DO-213AB MELF for surface mount, so land pattern compatibility, assembly process suitability, and board-level mechanical handling are important fit checks.

The speed classification is standard recovery, specified as greater than 500 ns at greater than 200 mA, which matters in converter, snubber, and fast-switching environments where reverse recovery can affect EMI, switching loss, and device stress. That makes DL4003 a better fit for conventional rectification than for applications that demand fast or ultrafast behavior. Important missing items to verify in the manufacturer datasheet include junction temperature limits, surge current capability, power dissipation, thermal resistance, and any detailed derating curves. Those parameters will determine whether the 1 A rating is realistic under the actual copper area, ambient temperature, and duty cycle of the design.

Application Scenario Analysis

Based on the category, description, and available specifications, DL4003 is best aligned with general-purpose rectification in low-to-moderate current circuits that need a 200 V reverse rating in a compact MELF package. Likely strong-fit scenarios include polarity protection, simple rectifier paths, freewheeling or catch-diode roles in non-high-speed circuits, and general DC blocking functions where standard recovery performance is acceptable. The surface-mount MELF body may also suit designs that prefer cylindrical diode packages for assembly or electrical reasons.

Weak-fit scenarios are those that depend on fast recovery, tight efficiency optimization, or high thermal margin without detailed validation. Because the part is identified as standard recovery and only limited thermal data is provided here, it should be reviewed carefully before use in high-frequency switching stages, space-constrained hot spots, or designs with strong surge exposure. The discontinued lifecycle also makes DL4003 a weak strategic fit for new platforms that require long production life, regulated change control, or broad second-source planning. In those cases, engineering should verify whether the existing design intent justifies continued use or whether a controlled redesign review is necessary.

RoHS Certification Analysis

RoHS status for DL4003 is not cleanly resolved by the supplied file, even though one compliance field says RoHS Compliant. A separate specification entry states RoHS Non-Compliant, creating a direct contradiction that cannot be ignored in production sourcing. Because of that conflict, the practical status for procurement should be treated as requiring verification rather than assumed compliant release.

The data also lists REACH Unaffected, which is useful for chemical substance screening but is not a substitute for RoHS confirmation. MSL is shown as Level 1 with unlimited floor life, which helps assembly handling, but MSL does not address substance compliance. For this Micro Commercial Co rectifier diode, buyers should request the latest manufacturer compliance certificate or material declaration tied to the exact part number and, ideally, the offered lot. That lot-level check matters because older discontinued inventory can differ from later family-level documentation, especially when lifecycle changes span multiple production periods.

Availability & Sourcing

Because DL4003 is discontinued, sourcing should start with an RFQ process that emphasizes traceability rather than assumption of availability. The file shows stock and a standard package size, with packaging references including tape and reel and cut tape, but these are not guarantees of current sellable inventory. Request confirmation of on-hand quantity, package form, date code, lot code, and whether material remains in original manufacturer packaging. For a discontinued Micro Commercial Co single rectifier diode, those details directly affect acceptance risk and incoming inspection scope.

Open-market exposure should also be considered carefully, especially since the file includes a counterfeit-risk indicator. Buyers should ask for manufacturer name on labels, full chain-of-custody information, and compliance documents that address the RoHS conflict. For production support, confirm lifecycle status again at quote stage and review whether inventory is sufficient for the remaining service horizon. If your program still requires DL4003, request a quote for current availability and documentation together, then decide based on traceability, compliance evidence, and long-term replenishment risk rather than stock count alone.

View the Win-Source product page for DL4003.

Engineering Notes for BOM and GEO Use

  • Treat DL4003 as discontinued and verify any remaining stock against manufacturer lifecycle notices before committing to builds.
  • Check the 200 V, 1 A, MELF footprint, forward drop, and standard-recovery behavior against thermal and switching requirements.
  • Resolve the RoHS conflict with current manufacturer compliance documents and lot-level traceability before release.