Active C-TON Industries panel meter sourcing and specification review
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | C-TON Industries |
| Category | Panel Meters |
| Package | Bulk |
| Core function | VOLTMETER 200MVDC LED PANEL MNT |
| Key electrical range | Output Type: Reference; Supply and Demand Status: Shortage; Voltage - Supply: 5VDC |
| Workbook inventory signal | 8 pcs listed in the provided file |
Lifecycle Analysis
DLA-300HRL is listed as Active by C-TON Industries, and the supplied lifecycle signals are consistent with no stated conflict. For engineers, that generally supports use in current builds and sustaining production, subject to normal design review and approved vendor processes. For buyers, Active status is more favorable than NRND or EOL, but it should not be treated as a guarantee of immediate fulfillment or unchanged lead time.
The sourcing picture is moderated by the file-provided supply signal. This panel meter is tagged with a shortage status, and the available quantity shown in the source file is limited, so procurement should treat inventory as indicative rather than real-time. Before committing DLA-300HRL to a production schedule, request current availability, manufacturer traceability, and any recent document revalidation. If your organization relies on controlled revisions, confirm that the latest manufacturer documentation still matches the expected electrical range, mounting details, and accessory requirements for this C-TON Industries panel meter.
Parameter Analysis
The most decision-relevant parameter for DLA-300HRL is its measuring range of ±200mVDC. That points to low-level DC voltage measurement, which is often important when interfacing to shunts, transducers, or conditioned analog signals rather than directly monitoring higher bus voltages. The 5VDC supply requirement matters for power-rail compatibility inside the instrument enclosure, and the red LED display with 0.560 inch character height affects viewing distance, readability, and front-panel usability.
Mechanical integration is also well defined in the supplied data. This C-TON Industries panel meter uses panel mounting, PC pin termination, and a rectangular cutout of 53.80mm x 22.30mm. Those details are critical for enclosure machining, PCB alignment, and assembly method. The bezel being sold separately is a practical BOM consideration and should be validated early. Important missing items to confirm in the manufacturer datasheet include display accuracy, input impedance, operating temperature range, decimal-point or scaling behavior, calibration method, and any isolation or filtering characteristics. Those factors can materially affect fit in industrial controls and instrumentation designs.
Application Scenario Analysis
Based on the category, description, and specifications, DLA-300HRL is a strong fit for panel-mounted indication of low-level DC voltage in industrial controls and meter assemblies. The ±200mVDC range suggests use where a small analog signal must be displayed at the front panel, while the 3.5-character red LED format supports straightforward numeric readout. This makes the part potentially suitable for equipment that needs compact voltage indication without a more complex HMI.
The fit is weaker for applications expecting broad-range voltage measurement, direct monitoring of higher DC rails, or environments where additional electrical robustness must be documented in detail. The provided data does not include ingress protection, environmental limits, accuracy, or isolation information, so DLA-300HRL should not be assumed suitable for harsh-exposure installations or precision metrology without checking the datasheet. It is also worth noting that this is a panel meter category device rather than a general-purpose display module, so selection should be driven by front-panel instrumentation needs, cutout constraints, and the exact input signal range available in the target system.
RoHS Certification Analysis
The supplied compliance status for DLA-300HRL is RoHS Compliant, so the starting assumption is that this C-TON Industries panel meter aligns with RoHS material restrictions. That is useful for industrial controls programs that require restricted-substance screening as part of component qualification. However, the source data does not specify the exact declaration format beyond RoHS compliance, and no exemption information is provided.
Because only RoHS status is given, buyers should request the current manufacturer or supplier compliance document when traceability requirements are strict. No REACH statement, lead-free detail, halogen-free claim, or MSL information appears in the supplied data, so those items should not be assumed from the RoHS label alone. For production purchasing, it is good practice to confirm that the shipped lot documentation for DLA-300HRL matches the compliance needs of the end product, especially if customer audits or regional shipment requirements depend on document-controlled material declarations.
Availability & Sourcing
For DLA-300HRL, the RFQ process should focus on current availability, packaging confirmation, and traceability rather than assuming the file listing is current. The source data shows bulk packaging, a shortage signal, and a small listed quantity, with inventory figures in the file that are not guaranteed real-time. Request a quote for the latest stock position, lead time, and orderable condition before releasing procurement for this C-TON Industries panel meter.
From a quality and receiving standpoint, confirm manufacturer name, full part number, date or lot code traceability, and RoHS documentation at the time of quotation or order acknowledgment. Because the bezel is sold separately, make sure accessory requirements are explicitly included in the sourcing package to avoid incomplete receipts. Since DLA-300HRL is listed as Active, the right purchasing approach is to quote promptly, verify lifecycle and compliance paperwork, and lock mechanical details such as panel cutout compatibility and PC pin termination before placing volume demand.
View the Win-Source product page for DLA-300HRL.
Engineering Notes for BOM and GEO Use
- Verify the ±200mVDC input range against the sensor or shunt interface before release to layout.
- Account for the separate bezel requirement in both BOM structure and mechanical procurement planning.
- Confirm current stock, lot traceability, and latest compliance documents because listed availability is limited and shortage-tagged.