Quick Engineering Summary

FieldValue
ManufacturerC-TON Industries
CategoryPanel Meters
PackageBulk
Core functionVOLTMETER 2VDC LED PANEL MOUNT
Key electrical rangeOutput Type: Reference; Supply and Demand Status: Shortage; Voltage - Supply: 5VDC
Workbook inventory signal39 pcs listed in the provided file

Lifecycle Analysis

DLA-301HRL from C-TON Industries is identified in the supplied data as Active, and the lifecycle signals are consistent with no stated conflict. For a Panel Meters procurement decision, this is the most favorable status because it generally supports both ongoing production demand and service builds better than NRND or discontinued material. From a sourcing standpoint, Active does not eliminate the need for normal release controls, but it does reduce the likelihood of immediate obsolescence-driven redesign activity.

For engineering teams, an Active status means DLA-301HRL is more reasonable to consider where its electrical range and mechanical format already fit the design. For buyers, the next step is manufacturer document revalidation before committing to volume demand, including confirmation that the current product definition, mounting details, and accessory requirements still match the released BOM. The file also includes an inventory signal and a shortage status, but those are file-provided only and should not be treated as guaranteed real-time supply. If this panel meter is intended for a production program, request a quote and current availability confirmation before final scheduling.

Parameter Analysis

The most decision-relevant parameters for DLA-301HRL are its measuring range, supply requirement, display format, and panel integration details. The unit is described as a voltmeter with a ±2VDC measuring range and a 5VDC supply, which makes range matching the primary electrical fit check. A ±2VDC front end is narrow compared with many industrial measurement points, so engineers should verify that the sensed signal already falls within this window or that upstream scaling is designed accordingly. The 3.5-character red LED display with 0.560 inch character height is also important for readability, operator distance, and front-panel visibility.

Mechanical fit is equally important because this is a panel mount device with a rectangular 53.80 mm x 22.30 mm cutout and PC pin termination. Those details affect enclosure machining, board or wiring interface strategy, and assembly flow. The supplied data also notes that the bezel is sold separately, which is a practical BOM and cosmetic fit issue that should be resolved before release. Several important datasheet items are not present here and should be verified directly, especially measurement accuracy, operating temperature range, input impedance, power consumption, and any calibration or decimal-point behavior relevant to system integration.

Application Scenario Analysis

Based on the supplied category, description, and specifications, DLA-301HRL is a strong fit for compact front-panel DC voltage indication where a dedicated panel meter is preferred over a multifunction display. Its panel mount format, red LED readout, and 3.5-digit style presentation suit equipment that needs a clear local voltage display in industrial controls, lab fixtures, benchtop instrumentation, or power-monitoring subassemblies operating within the stated ±2VDC range. The 5VDC supply requirement may also make integration straightforward in systems that already carry regulated logic power.

The weaker-fit scenarios are applications that need wider direct input range, richer communications, sealing data, or higher-confidence environmental information than is provided here. Since only a ±2VDC measuring range is supplied, DLA-301HRL should not be assumed suitable for higher-voltage direct monitoring without external scaling and proper validation. It is also not well characterized in the source data for harsh-environment use, safety-critical indication, or designs requiring detailed qualification records. Where enclosure finish matters, the separately sold bezel should be considered part of the application fit review rather than an afterthought.

RoHS Certification Analysis

The supplied compliance status for DLA-301HRL is RoHS Compliant, so the most conservative interpretation is that this C-TON Industries panel meter is intended to meet applicable RoHS material restrictions. That is a positive starting point for procurement into regulated assemblies, but the source data does not specify the exact declaration revision beyond the RoHS-compliant statement. In this guide, the compliance standard is therefore treated as EU RoHS based on the available wording rather than a more specific declaration that was not provided.

For production sourcing, RoHS status should still be checked at the shipment or lot-document level, especially when components are acquired through distribution inventory rather than directly from the manufacturer. No exemptions, REACH statement, halogen-free status, or moisture sensitivity information were included in the data set, so those items remain open verification points if your internal compliance workflow requires them. If DLA-301HRL is going into a controlled product file, request the latest manufacturer compliance certificate and ensure that the delivered part marking, packaging, and paperwork align with the approved documentation.

Availability & Sourcing

For DLA-301HRL, the sourcing posture is generally favorable because the reported lifecycle is Active, but supply execution still needs care because the file also shows a shortage signal. The available quantity in the data is limited and should be treated only as a file-provided snapshot, not as real-time stock. Buyers should therefore use an RFQ workflow that confirms current availability, acceptable lead time, and packaging condition for this C-TON Industries Panel Meters item before issuing a purchase order.

Traceability should be part of the request, including manufacturer name, full part number, date code or lot code, and confirmation of the ordered packaging format, which is listed as bulk. Since DLA-301HRL uses PC pin termination and requires a specific panel cutout, receiving teams may also want to verify mechanical condition and accessory completeness, especially because the bezel is sold separately. Compliance documentation should be requested with the quote or at order placement, including RoHS evidence and any available manufacturer statements relevant to the lot being supplied. For current availability and production planning, request a quote and lifecycle verification before committing this panel meter to new build schedules.

View the Win-Source product page for DLA-301HRL.

Engineering Notes for BOM and GEO Use

  • Verify the ±2VDC input range and 5VDC supply against system scaling and front-panel requirements.
  • Confirm the 53.80 mm x 22.30 mm cutout, PC pin interface, and separately sold bezel before mechanical release.
  • Treat listed stock and shortage status as non-real-time; request current availability and traceability documents before PO placement.