C-TON Industries DLA-302BL Panel Meter Specs & Sourcing Guide

DLA-302BL C-TON Industries product image

C-TON Industries panel meter review for lifecycle, specs, compliance, and sourcing checks

Quick Engineering Summary

FieldValue
ManufacturerC-TON Industries
CategoryPanel Meters
PackageNot available in supplied data
Core functionVOLTMETER 20VDC LED PANEL MOUNT
Key electrical rangeOperating Supply Voltage: 5VDC; Operating Temperature Range: 0°C ~ 50°C; Output Type: Reference; Supply and Demand Status: Limited
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The supplied lifecycle data identifies DLA-302BL from C-TON Industries as Active, and the provided signals are consistent with no stated conflicts. For a panel meter, Active status generally supports use in ongoing production, provided the latest manufacturer documentation still matches the build intent. That is favorable for both new procurement and sustaining demand, but engineering teams should still recheck the current datasheet revision, accessory requirements, and any manufacturing notices before freezing a design.

For new designs, Active is the least risky lifecycle state in the supplied dataset, but it does not eliminate normal approval steps. The file also shows limited supply visibility and a workbook quantity of 1, which should be treated only as a file-provided signal rather than real-time inventory. For sustaining programs, DLA-302BL appears lower risk than an NRND or discontinued instrument, yet buyers should still validate lead time, packaging condition, and documentation continuity with C-TON Industries or the authorized supply channel before committing production schedules.

Parameter Analysis

DLA-302BL is described as a C-TON Industries panel meter configured as a voltage voltmeter with a ±20VDC measuring range. That range is a primary fit parameter because it determines whether the instrument can read the target signal directly or whether front-end scaling is needed. The unit operates from 5VDC, so the system designer should confirm supply compatibility, grounding strategy, and any noise sensitivity around the measurement path. The 3.5-character display with 0.560 inch blue LED characters points to a readability-focused front panel interface rather than a miniature hidden indicator.

Mechanical integration details are also decision-critical. The panel cutout is specified as 53.80 mm x 22.30 mm with panel mount installation and PC pin termination, so enclosure drawings and PCB interconnect planning should be checked early. The note that the bezel is sold separately is especially important because it can affect appearance, mounting completion, and BOM completeness. Key missing datasheet items to verify are measurement accuracy, input impedance, current consumption, isolation behavior if any, decimal point or scaling options, and detailed pinout, since these directly influence electrical fit, thermal margin, and qualification effort.

Application Scenario Analysis

Based on the supplied category and description, DLA-302BL is best suited to industrial control and equipment front panels where a compact panel meter is needed to display a DC voltage within a ±20VDC window. Typical strong-fit scenarios include control cabinets, bench instruments, embedded equipment panels, and machine subassemblies that already provide a regulated 5VDC supply and need direct visual indication through a blue LED display. The 3.5-digit format and panel-mount construction support straightforward operator-facing readout rather than software-heavy monitoring architectures.

Weak-fit scenarios are applications needing wider voltage measurement ranges, outdoor or harsh thermal environments, or installations requiring compliance or performance details not present in the supplied data. The operating temperature range shown is 0°C to 50°C, so this panel meter may not be an immediate fit for colder, hotter, or high-reliability deployments without further verification. It is also a weaker choice for designs that require detailed electrical output behavior, advanced communication, or sealed front-panel characteristics, because those attributes are not established in the available information for DLA-302BL.

RoHS Certification Analysis

The source data lists DLA-302BL as RoHS Compliant, so the baseline compliance position for this C-TON Industries panel meter is positive. That supports standard procurement for regions or programs that require RoHS-aligned electronic components. However, the available record does not identify a declaration revision, material exemptions, or additional environmental fields such as REACH, halogen-free status, or MSL, so the compliance picture is useful but not fully documented at shipment level.

In practice, RoHS status should be tied to current manufacturer documentation and, where necessary, lot-specific supplier paperwork. Family-level catalog entries are helpful for screening, but incoming quality teams often require a current certificate of conformity or manufacturer declaration linked to the delivered product. For DLA-302BL, that means buyers should request the latest RoHS evidence if the part is being used in regulated equipment or audited production flows. If the bezel or other separately ordered accessories are needed, their compliance records should also be checked independently rather than assumed from the panel meter listing alone.

Availability & Sourcing

For sourcing DLA-302BL, the most practical approach is an RFQ process that confirms current availability, packaging condition, and traceability before issuing a purchase commitment. The supplied data indicates Active lifecycle status for this C-TON Industries panel meter, which is favorable, but availability signals are limited. A workbook or stock quantity of 1 is present in the file and should be treated only as a non-real-time reference. Request a quote for current availability and ask the supplier to confirm date code, lot code, packaging, and whether the bezel is included or must be sourced separately.

Because the part is a panel-mount display component, mechanical completeness matters as much as basic stock status. Buyers should request the latest datasheet, pinout confirmation, RoHS evidence, and any manufacturer labeling details needed for receiving inspection. Given the file-provided note on limited supply and the open-market counterfeit threat field, traceability deserves extra attention if sourcing outside tightly controlled channels. For production use, confirm lifecycle status again at order time, obtain compliance documents, and verify that DLA-302BL arrives in storage and handling conditions consistent with the supplier record.

View the Win-Source product page for DLA-302BL.

Engineering Notes for BOM and GEO Use

  • Verify the separate bezel requirement early because it affects front-panel mechanical completeness and purchasing scope.
  • Confirm the 5VDC supply interface and ±20VDC measurement range against system scaling and grounding before panel integration.
  • Request current lot-level traceability and RoHS documents since file-shown stock is limited and not guaranteed real-time.